Filter Results By:

Products

Applications

Manufacturers

Showing recent results 1036 - 1050 of 1067 products found.

  • Thermometers

    PCE Instruments

    At PCE you will find both a contact and non-contact thermometer for measuring and recording temperature. There is a thermometer to measure different temperature ranges between -200 and 1767ºC / -328 ... 3212ºF. Measurement of temperature is done in many different sectors. We also offer a thermometer that can indicate temperature in ºC, K (Kelvin) and ºF, as well as another that is water resistant.A wide range of thermal elements and type-K sensors are available for the thermometer. ISO calibration certificates, which include a laboratory calibration, can be ordered for most models in our thermometer range. Thermometers are instruments we use to measure the temperature of people or things.The most used and known thermometers are mercury thermometers used to measure peoples temperature and consisting of a graduated glass capillary and a pool of mercury in one end, but there are many types of thermometers such as digital thermometers that we have introduced which take temperature measurements on contact with an object these are suitable for any sector of industry. We even have infrared or laser thermometer to take measurements at distance, without contact.

  • Archival Storage Rooms

    Darwin Chambers Company

    Darwin Chambers Company’s NFPA, GSA, and NARA Directive 1571-compliant Archival Storage Chambers are engineered to provide maximum value, efficiency and conformance with all applicable standards and codes. Archival chambers provide environmental controls for storing records and materials (including paper documents and items with high fibrous content, various films, microfiche, and photographic materials) that require permanent protection for storage and preservation. Our high-performance systems are offered with nearly unlimited operational fail safes, includ- ing full system and control redundancy. In addition to keyed entry, numerous security options are also available, due to the often irreplaceable nature of the materials to be stored and preserved in this type of chamber. Our chambers are engineered to accommodate the loads and unique requirements of the specific materials to be stored, with industry-leading control and uniformity of both temperature and humidity variables. Design considerations include both functional and operational efficiencies and reliability, the safety and comfort of operating personnel, and the ongoing protection of the archived materials from fire, water, light degradation, pests, mold and natural contaminants, pollutants and other man- made threats.

  • Analog Input Products

    Acces I/O Products, Inc.

    Analog input boards are useful for measuring variably changing conditions in the real world. When we want to measure these variably changing conditions, we need analog inputs to convert these changing real world conditions to changing electrical quantities. For example, monitoring the temperature inside a wood kiln, or the water pressure on the output of a pump, or the heart rate of a medical patient. In each of these cases, you can use one of our analog input devices to convert the electrical data from a sensor or transducer into binary data that can then be used by your computer. The device that converts this data is known as an analog to digital converter (abbreviated ADC, A/D, or A to D). An analog input is a measurable electrical signal with a defined range. The analog input changes continuously in a definable manner in relation to the measured property. This data is very useful for process monitoring, process control, or simple monitoring / data collection and acquisition. ACCES' analog input boards amplify and multiplex input signals from thermocouples, strain gauges, accelerometers, photo sensors, flowmeters, RTDs, thermistors, voltage sources, millivolt sources, and current sources, just to name a few.

  • Rugged IP67-rated Fanless Edge System With NVIDIA® Jetson™ TX2, HDMI, GbE LAN, 1-CH PoE, USB 2.0 And 100 To 240 VAC Power Input

    eBOX800-900-FL - Axiomtek Co., Ltd.

    The Artificial Intelligence (AI) embedded system, eBOX800-900-FL, adopts a full IP67-rated extruded aluminum and heavy-duty steel case for dust protection and water resistance. Moreover, the AI embedded system comes with a wide operating temperature range of -30°C to 60°C (-22°F to +140°F) and a vibration endurance for up to 3Grms. The embedded system is powered by the NVIDIA Jetson™ TX2 module which has a powerful 64-bit ARM A57 processor and 256-core NVIDIA® Pascal GPU. It features M12 type I/O connectors and four N-jack waterproof antenna openings for operational stability in rugged environments. The eBOX800-900-FL is ideal for AI edge computing and deep learning applications, such as smart city, smart manufacturing, smart transportation, and much more. The eBOX800-900-FL has 8GB of LPDDR4 memory and 32GB eMMC onboard. It comes with a wide range of 100 to 240 VAC power input with 10kV surge protection. The rugged edge computer also features one M.2 SSD PCIe 2.0 x4 socket which supports high-performance NVM Express interface for extensive storage needs. Furthermore, the embedded box PC is equipped with a PoE port to support the applications that require the use of IP cameras or any PoE device, i.e., traffic flow monitoring, license plate recognition, vehicle recognition, machine vision.

  • Fully Automatic Diagnostic Insulation Tester 10KV- 10KPI

    The Motwane Manufacturing Company

    Model 10K PI is a diagnostic insulation tester having test voltage range upto 10KV; an Indigenous MOTWANE designed to conduct automatic diagnostic tests on high voltage equipments like Transformers, Cables, Bushings,Switchgears & rotating machines. 10K PI is microprocessor based instrument deploying latest technology & very high speed data sampling to give correct, repetitive readings & quality performance under harsh electrical conditions. It has wide insulation resistance range up to 20T ohm.Model 10K PI is mains and battery operated portable & compact insulation tester for outdoor applications. The battery backup of 6 hours make it suitable for field operations.IP54 rating keeps 10K PI safe from water & dustingress. It complies with CAT IV 600V for safe operation. The instruments & its accessories are certified as perrelevant IS/IEC standard.The Information displayed on large backlit LCD display includes insulation resistance, leakage current, capacitance,battery status & timer. Three programmable timers are provided to conduct various tests like Polarization Index (PI),Dielectric Absorption Ratio (DAR), Dielectric Discharge (DD), Step Voltage (SV), & breakdown Voltage (BDV) test.10K-PI can store 1000 test results. PC interface via USB & RS 232for data transfer. The software for report generation & data trending analysis helps to keep records of capital equipments.

  • Sand And Dust Test Chamber

    ACE Technology

    1.Application area:  This product is applicable for the dust proof and resistant test of various auto components and parts including lamps, meters, electric dust proof sheath, steering system and lock, etc.  2. Standard conformed   DIN, GB4208, GB4706, GB2423, GB/T2423.37  3.Features  Digit-display programmable controller controls time and order for working or interval.  World-famous key implementing components, ensure excellent performance and reliability.  Big viewing windows, observe specimen condition clearly anytime.  4.Executive components  Programmable controller, with digital display.  Schneider AC contactor, switch and button.  Panasonic time relay.  Panasonic dust proof socket.  Specimen power socket: dust-proof style socket AC220V, 16A    B.CONTROLLER  Digital-display programmable controller, control the time and orders of the whole system.  1.Controller: imported microprocessor programmable integrated controller.   2.Vacuum system: equipped with pressure meter, air filer, pressure adjusting 3-united components, connecting pipe.  3.Cycling blower: closed alloy electric machine, low noise, multi-blade centrifugal blower.   4.Powder heating system: stainless steel mica plate heating jacket.    Remark: Vacuum pump is optional.    C.SAFETY DEVICES  Protection for: leakage of electricity, short circuit, extra-temperature, lack of water, extra-voltage.   Memory function when controller power shut off.     D.ACCESSORIES  1.Technical data: certificate of quality, warranty card, operation and maintenance manual.  2.Enclosure:a set of quick-wear part

  • Non Destructive Testing (NDT)

    Keighley Laboratories LTD

    NDT covers a wide group of testing techniques used to evaluate the properties of a material, part, product, weld or system without causing damage. NDT carried out at KLL includes:Liquid Penetrant Testing (LPT) is used for the detection of surface breaking discontinuities on magnetic and non-magnetic metallic materials.Fluorescent and colour contrast penetrants are available to be used in the following methods:-Water washableSolvent removablePost emulsifiableMagnetic Particle Inspection (MT/MPI) is used for the detection of surface breaking and slightly sub-surface (up to 2mm) discontinuities.Bench type crack detectors and portable units are employed producing various waveforms (i.e. A.C, HWDC and induced magnetic flow) to give both circular and longitudinal magnetism.On-site testing is carried out using electro magnetic yokes and permanent magnets producing induced magnetic flow.Ultrasonic Flaw Detection (UT), also known as Ultrasonic Inspection, is used for the detection of volumetric discontinuities in ferrous and non-ferrous products (forgings and castings etc.), and welds in magnetic and non-magnetic materials.UT is capable of penetrating metals, dependent on the material characteristics, up to 10m in length.Some thickness and depth checks can also be carried out using ultrasound.Radiography services are available through sub-contract booked in advance. Notice is required for on-site work.Personnel are available at short notice for in-house or on-site work in the UK and overseas.All inspectors undertaking non destructive testing (LPT, MT/MPI and UT) are qualified to, and meet a minimum of, PCN Level 2.PCN Level 3 supervision is available in-house for LPT, MT/MPI, UT offering consultancy services including procedure writing and commentary, auditing of techniques and Level 3 Supervisor cover.We can assist clients in product qualification, material testing, quality assurance and audit programmes.

  • BENCH TOP HEATING AND CHILLING INCUBATOR

    HC-3 - Canden Products LLC

    HC3- 3 cu.ft laboratory incubatorTemperature range--4°C to 50°CTemperature uniformity--± 0.7°CThis is a 3 cu.ft laboratory incubator capable of performing in wide temperature range(4°c to 50°c) with precise temperature control over the entire range. The heating/chilling incubator can be used in wide range of application including;Protein crystal growthEnzyme reactions and deactivationsLigationsIncubating marine cultures below ambientCulture growth above, below or at ambientStoring DNA librariesChamber features all stainless steel interior and exterior construction with 2″ polyurethane CFC free insulation.Chamber feature a unique double shell-filled with commercial-grade polyurethane material for optimal insulation. Inlaid sealing ring and nylon latch for enhanced seal/performance. The chamber is made out of LLPDE material shell.The chamber comes with 12 molded slots. We provide 2 wire shelves with each chamber. Additional shelves are available for purchase. Shelves can support up to 25lbs distributed load. The Chamber comes with 2 hidden molded handles that enables users to move the chamber with ease. The chamber is also stackable without additional parts.Chamber uses thermoelectric assembly for heating and cooling. This type of cooling/heating system completely eliminates need for conventional refrigeration system and failures due to mechanical components such as compressors thereby drastically increasing the life expectancy of each chamber. Maintenance cost is also lowered by the thermoelectric/Peltier driven heating/cooling system. The chamber is quiet (less than 55dba) while in operation. Chamber temperature setpoints are tightly controlled using PID controller. Relative humidity set points are achieved via additive ultrasonic humidification. A humidifier is mounted on the back of the chamber. Refer to humidifier manual for maintenance and water line hook up.

  • High Temperature Self-Supporting Furnace Extensometers (1200 C)

    Model 3448 - Jinan Testing Equipment IE Corporation

    Epsilon developed this unique high temperature extensometer for testing metals, ceramics, and composites at the high temperatures produced by furnaces and induction heating systems. A combination of features make these extensometers easier to use and better in performance than other similar high temperature extensometers.The units are held on the specimen by light, flexible ceramic fiber cords. These make the extensometer self-supporting on the specimen. No furnace mounting brackets are required. The side load on the test sample is greatly reduced because of the self-supporting design and light weight of the sensor. Most materials testing furnaces with a side cut-out for an extensometer will readily accept a Model 3448. For induction heating systems, a different ceramic cord placement allows the extensometer to easily pass between the coils.The combination of radiant heat shields and convection cooling fins allow this model to be used at specimen temperatures up to 1200℃ (2200°F) without any cooling. An optional tiny air fan does enhance stability at the highest temperatures and is recommended for the highest accuracy and for tests with small elongations. The fan comes with a magnetic base for support so it can be mounted at any convenient location near the extensometer. Fan cooling is not generally needed for induction heated systems. High purity alumina ceramic rods are used. These are available in lengths as required to fit your furnace. A spare set is included with every extensometer. Specify chisel, vee chisel or conical contact points as desired.Most units operate equally well in tension and compression. Thus tensile, compression and cyclic tests like low cycle fatigue can all be performed with a single unit.For vacuum furnaces, special models are available. Epsilon can also provide a radiant heat transfer cooled version. This requires that the extensometer module be surrounded by a water cooled enclosure with a front slot for the ceramic rods.

  • Temperature Meters

    PCE Instruments

    PCE Instruments’ temperature meter products are precise, portable, handheld devices ideal for professional, industrial, commercial and residential use. From contact temperature meter devices with probes to noncontact temperature meter devices using infrared or laser technology to measure temperature from a distance, PCE Instruments offers a wide range of accurate, reliable temperature meter products at an affordable price.Temperature is measured and recorded in many different applications. For example, HVAC technicians measure temperature to identify and address issues in heating or cooling systems, while quality control professionals in the food sector measure temperature to ensure the proper storage and preparation of everything from meat and produce to cheese and frozen foods. PCE Instruments carries a variety of temperature meter products, including temperature meter devices to measure different temperature ranges between -200 and 1767ºC / -328 ... 3212ºF; temperature meter devices that can indicate temperature in °C (Celsius), °K (Kelvin) and °F (Fahrenheit); and temperature meter devices that are water resistant. In addition, a number of thermal elements and type-K sensors are available for different temperature meter products.Each temperature meter comes factory calibrated to ensure accurate measurement. ISO-certified calibration, performed by one of our first-class calibration laboratory partners, may be obtained on most temperature meter models for an additional fee.A temperature meter is an instrument used to measure the temperature of beings or things. The most widely recognized temperature meter is a mercury thermometer used to measure the temperature of people. These thermometers consist of a graduated glass capillary with a pool of mercury in one end. However, there are many different types of temperature meters, such as digital thermometers that take temperature measurements on contact with an object or infrared temperature meters that take measurements at distance, without contact.

  • Paper Moisture Meters

    PCE Instruments

    A paper moisture meter measures the humidity of paper and paper products. Use of a paper moisture meter can prevent costly damages resulting from paper expansion or shrinking. A paper moisture meter determines paper moisture content based on either absolute humidity or relative humidity. Absolute humidity does not take into consideration temperature, while relative humidity relies on temperature and is expressed as a percentage of the total amount of moisture possible at the current temperature. Thus, many paper moisture meter devices feature automatic temperature compensation (ATC).For paper producers, paper manufacturers, paper mills and others in the pulp and paper industry, moisture and humidity control is essential, especially during the production process, as excessive moisture can lead to warming of the paper rolls. A paper moisture meter can be used to detect moisture streaks during the paper production process as well as to identify optimal drying times.Regardless of whether paper is stored in paper rolls in paper converting plants or stacked in sheets and paper bales in commercial printing warehouses, the porous surface of paper gradually takes in moisture relative to the humidity of the surrounding environment. This moisture can be problematic, as too much moisture can cause curling, buckling or the formation of waves in otherwise flat paper products. Moisture also can prevent inks, dyes, paints and coatings from covering and saturating paper properly during printing and processing.PCE Instruments (PCE) offers digital handheld moisture meter devices for measuring the moisture content of paper and paper products such as cardboard, paperboard, corrugated boxes, craft paper, wrapping paper, brown packaging paper, butcher paper, recycled paper, coated paper and more. Different paper moisture meter models utilize different paper moisture measuring techniques, performing moisture content tests of paper products via either destructive or nondestructive methods. Typically, a standard pinless paper moisture meter is nonpenetrating, thus allowing for the nondestructive measurement of paper water content.

  • Very Low Pressure Variable Reluctance Sensor

    DP103 - Validyne Engineering

    The Validyne DP103 is designed for exceedingly low differential pressure measurement applications where high accuracy is required under rough physical conditions. With full scale ranges down to -0.008 psid (-0.56cm H2O), this instrument is being used in the measurement of very low flow rates of gases where symmetrical pressure cavities are required for dynamic response. It is also used in very small leak detection and pressure null detection systems.

  • Draft Range Trasmitter

    DR800 - Validyne Engineering

    The Validyne Model DR800 Draft Range Transmitter is designed exclusively for very low pressure measurement needs. It has a "true" full-scale range as low as 0.25" H2O, making it ideal for air flow control applications. It can be turned down to 0.1" H2O; higher full-scale ranges to 100" H2O are available. The DR800 offers 0.5% accuracy and an operating temperature range of -20F to +185F. The total combined temperature effects are less than 3%/100F.

  • Ultra Low Pressure Transmitter

    P532 - Validyne Engineering

    Validyne's P532 Pressure Transmitters are ideally suited for measuring extremely low liquid and gas pressures in industrial applications. Full-scale differential pressure ranges from 0.10 H2O to 2 H2O with line pressure rating of 100 psig, and ranges of 2 H2O to 3200 psid with line pressures up to 3200 psig are offered. Gauge pressure ranges start at 0.10 H2O and absolute pressure from 0.08 psia full-scale. This unique design, which utilizes a diaphragm-type variable reluctance pressure sensor, provides many outstanding advantages including:

  • BHF Concentration Monitor

    CS-137 - HORIBA, Ltd.

    The CS-137 is a high-precision chemical solution concentration monitor designed to meet the strict demands of semiconductor wet-etching processes. Etching processes use BHF solution to etch silicon oxide and remove particles from the wafer surface. The CS-137 continually monitors each component of the BHF solution (NH4F/HF/H2O), alerting the user each time the solution is replaced or replenished. This allows you to maintain the concentration of the BHF solution within the required component ranges, while eliminating unnecessary solution replacement.