  • Weschler Zahn Viscosimeter

    Weschler Instruments

    The Zahn viscosimeter is a bullet-shaped, corrosion-resistant, stainless steel cup with a precision drilled orifice. Five sizes are available for use on very thin oils to extremely heavy mixtures (20-1200 Centipoise). Viscosity is determined by the time required for a definite volume of liquid to flow through the orifice. These easy-to-use products were originally manufactured by G.E. and are still Made in USA.

  • Process Systems And Integration

    Anton Paar GmbH

    For 50 years, Anton Paar has been pushing the limits in process sensor technologies, providing superior products in the fields of density, viscosity, O2, CO2, and refractive index measurement for a wide range of industries, including the beverage, chemical and petroleum industries. Now Anton Paar extends its product portfolio by offering complete process engineering solutions.

  • Dynatrol® Density Cells

    CL-10HY - Automation Products, Inc.

    The Dynatrol® CL-10HY Density Systems achieve exceptional accuracy over a wide range of process changes in ambient temperature, pressure, viscosity or flow. Our systems are designed for density measurement in familiar units like specific gravity, API gravity, Baumé, BRIX°, as well as being able to measure the percent solids or percent concentration of a liquid or slurry.

  • Oil BDV Tester

    Weshine Electric Manufacturing Co., Ltd

    Insulating oil in electrical power apparatus serves two primary roles, as an insulator and a coolant. As an insulating liquid, oil’s most important property is a high dielectric strength and as a cooling liquid, a low viscosity is paramount. The principal nemeses of insulating oil are oxidation, contamination (particularly moisture, which tends to lower the dielectric properties of insulating oil), and excessive temperature.

  • Flow Computers

    Badger Meter

    Cox FC30 flow computers service both liquid and gas applications. The FC30 features batching, 40-point flow meter linearization tables, and temperature viscosity correction using Strouhal/Roshko advanced linearization methods and multiple flow and control inputs. Relay outputs are independently assignable for alarms and general purpose warnings. The FC30 has serial communications, both RS232 and 485, and isolated analog and pulse outputs.

  • Viscometers

    GAO Tek Inc.

    GAOTek proudly presents a wide range of viscometers. A viscometer is used to measure the viscosity of a fluid or liquid under a certain flow conditions. Thus, viscometers only measure under one flow condition. Different types of viscometers have either the fluid stationary which allow object to pass through or vice versa. Therefore, these devices measure the drag caused by the interaction between the fluid and object surface.

  • Viscometers

    GAO Tek Inc.

    GAOTek proudly presents a wide range of viscometers. A viscometer is used to measure the viscosity of a fluid or liquid under a certain flow conditions. Thus, viscometers only measure under one flow condition. Different types of viscometers have either the fluid stationary which allow object to pass through or vice versa. Therefore, these devices measure the drag caused by the interaction between the fluid and object surface.

  • Food Testers

    IMADA, Incorporated

    These automated food testers are designed for clean, smooth trouble-free operation.Food Rheology testers automatically test firmness, elasticity or viscosity using a load cell combined with programmable movement control. The easy-to-use program dial and menu screens control probe positioning and speed. Select from three movement patterns. The USB port streams 1,000 force data/second to the Force Data Analysis Software (included).

  • Positive Displacement Meter

    Badger Meter

    The Blancett positive displacement flow meter provides high measurement accuracy for fluids over a wide viscosity range. Applications include lubricants, fuels, chemicals and solvents, oils and greases. With only 2 moving parts, the positive displacement meter offers trouble free operation and long service life. The meter is bi-directional and it has an extremely large turndown ratio, up to 400:1 in some models - with full accuracy at extremely low flow rates.

  • Automatic Continuous Online Monitoring of Polymerization Reactions

    ACOMP - Fluence Analytics

    ACOMP is a smart manufacturing system that continuously analyzes polymers during production. This automated monitoring solution produces realtime insight about reaction kinetics and polymer properties such as residual monomer, monomer conversion, polymer composition, molecular weight and intrinsic viscosity. ACOMP enables optimized process control, resulting in increased polymer yield, quality and consistency, increased worker safety, reduced cycle time, reduced VOCs, and reduced energy and raw material usage.

  • High Performance UV Nanoimprint Resist

    AMONIL® - AMO GmbH

    UV Nanoimprint is a mechanical molding technique. A template made from quartz or a flexible elastomer with a 3D relief is brought into intimate contact with a UV-curable resist spin-coated on top of a substrate. Applying low imprint pressure at room temperature features are filled within seconds due to the low viscosity of the imprint resist. The resist is hardened via UV-light through the backside of the template. Finally substrate and template are separated. The replicated resist relief can further be transferred into the substrate via RIE-process or used as functional element.

  • Melt Flow Indexer

    MFI - Hanatek Instruments

    The Hanatek Melt Flow Indexer (MFI) is one of the most advanced instruments available for the measurement the melt characteristics of thermoplastic polymers.Understanding melt flow is a key indicator for producers, processors and converters of plastic materials as it dictates the temperatures and pressures required to manufacture consistent quality productsActual barrel temperature can be measured to ensure that every test is performed with complete compliance to ASTM D1238 (2011) Part A, B or C and ISO 1133 (2011) with full test documentation.Test TypesMFI/MFRMelt Volume RateMelt DensityShear Stress/RateMelt Viscosity

  • Melt Flow Indexer

    MFI - Rhopoint Instruments

    The Hanatek Melt Flow Indexer (MFI) is one of the most advanced instruments available for the measurement the melt characteristics of thermoplastic polymers.Understanding melt flow is a key indicator for producers, processors and converters of plastic materials as it dictates the temperatures and pressures required to manufacture consistent quality productsActual barrel temperature can be measured to ensure that every test is performed with complete compliance to ASTM D1238 (2011) Part A, B or C and ISO 1133 (2011) with full test documentation.Test TypesMFI/MFRMelt Volume RateMelt DensityShear Stress/RateMelt Viscosity

  • TDR Composite Cure Monitoring

    Material Sensing & Instrumentation

    MSI Time-Domain-Reflectometry (TDR) Composite Cure Monitoring [1-4] provides a new approach to cure monitoring of advanced polymer composites. Using a high-speed pulse and inexpensive microwave sensor, our TDR system follows rotation of a polar resin molecule, providing real-time information on viscosity and percent cure. Operating in the microwave frequency range, TDR Cure Monitoring provides an alternative between high-frequency fiber-optic methods and low-frequency dielectric methods, combining optical-style precision and miniaturization with electrode-based simplicity and robustness.

  • Portable Oil Lab

    FieldLab 58 - Ametek Spectro Scientific

    The Spectro FieldLab 58 is a rugged, portable expeditionary fluid analysis system that gives operators in the field the ability to perform comprehensive, mobile lubricant sampling. The battery-powered device enables complete lubricant assessment for condition monitoring and rapid results that permit informed maintenance decisions. It takes only 3 ml of oil to perform a comprehensive oil analysis and no chemicals or solvents are needed for sample preparation or cleaning. The complete analysis, with all four tests, only takes about 5 – 7 minutes, depending on oil viscosity.

Get Help