Showing results: 1 - 15 of 74 items found.
-
GTD-81 -
Kingrun Instrument Co., Ltd.
GTD-81 Insulation Oil Dissipation Factor and Resistivity Measuring System DTL, is designed and manufactured based on international standards. It is used for measuring dielectric dissipation factor and DC resistivity of insulating oil and other insulating liquids. The instrument is characterized by integrated structure, and integrates test cell, temperature controller, temperature sensor, dielectric loss test bridge, AC test power, standard capacitor, high resistance meter, DC high voltage source and other major components.
-
GTD-61A -
Kingrun Instrument Co., Ltd.
1. The GTD-61A Automatic Oil Tan Delta(OTD) & Oil dielectric loss tester is highly automated, allowing for the measurement of temperature rise, dielectric loss, and resistance in one go.
-
-
JY6601 -
Kingrun Instrument Co., Ltd.
JY6601 transformer oil insulating tester adopts completely new electromagnetic compatibility concept(EMC) which technology which will keep breakdown energy in a very low level,that will avoid pollution to oil sample during testing and make sure the test result are accurate and reliable.
-
SG-YD -
Wuhan Sangao Electrical Test Installations Limit Co.
AC and DC test oil immersed transformer.Traditional oil immersed test transformer is used to do power frequency withstand voltage and DC current withstand voltage test for variety kinds of high voltage electric device, insulating material.YD series oil transformer, also known as test booster, which test insulation strength under specified voltage for various electric products, components, insulation materials. It can test products insulation level, find insulation defect and judge overvoltage ability. It is widely used in power station, power supply and distribution system and research institute.
-
Shimadzu Corp.
It is necessary to analyze outgas in transformer insulation oil in power plant facilities. Shimadzu offers a System GC compliant with ASTM D 3612 Method B (oil stripper sampling) or ASTM D 3612 Method C (headspace sampling). The Nexis GC-2030TOGAS3 system, equipped with a PDHID, enables the analysis of more trace amounts of permanent gas than conventional systems.
-
JY6611S -
Kingrun Instrument Co., Ltd.
JY6611S transformer oil breakdown tester adopts completely new electromagnetic compatibility concept(EMC) which designed to avoid tester crash accident during testing, and also can still work well in high magnetic field.JY6611S also use advanced voltage breakdown control technology which will keep breakdown energy in a very low level, that will avoid pollution to oil sample during testing and make sure the test result are accurate and reliable.
-
-
-
HBVT -
Hention Electrical Equipment Co., Ltd.
HBVT Transformer Oil Breakdown Voltage Tester , in accordance with IEC156, is designed to check insulating oil’s dielectric strength.The test set is compact and portable, therefore suitable for field work.
-
Neutronics Manufacturing Co.
NMC''s Transformer BDV Oil Test Set is a portable unit as per relevant Indian Standard Specification IS :6792 :1992, suitable for operation on 230 / 240 Volts, A.C. 50 Hz. A three core flexible cable is connected to the unit with three pin socket to connect the mains. The H.V. Transformer is a completely dry, resin encapsulated with two H.V. terminals with mounting saddles. The center point of the transformer is earthed, so that the voltage of each terminal to earth is only half the test voltage.
-
-
LS -JJ-II -
Chongqing Lushun Scientific & Technological Development Co., Ltd.
1.The instrument has the function of automatic detection. 2.Tiny TPU-A panel printer is adopted for automatic printing out type insulating oil dielectric strength ATE is a full self-reacting device, which is developed according to the requirements in International IEC-156 and International GB507-86 "Insulating Oil Dielectric Strength Mensuration", combining the feedback opinions of all users .The instrument adopts singlechip as the leading part, and uses the method of "first setting and then testing". The whole process is controlled by automatic microcomputer. It is operated simply and used conveniently.
-
MG-II -
Chongqing Kailian Yongrun Industrial Co.,Ltd.
The dielectric breakdown voltage test (BDV test) is an important test to determine the breakdown voltage of insulating oils. After a certain period, transformer oil will be degraded, and there are moisture, gas and impurity in oil. Then, the quality of transformer oil is affected. So it is necessary to test the transformer oil. BDV test is one of the most common tests to insulating oils.
-
Neutronics Manufacturing Co.
We offer Manually operated Transformer Oil Testing Kits to check the DI-electric strength of the insulating Oils as per relevant specifications via. IS 6972. It is a useful equipment for transformer / switchgear manufacturing units. Oil frittering agencies, repair shop and electrical maintenance departments.