Filter Results By:

Products

Applications

Manufacturers

Transducers

1) convert energy into an analogous electrical signal. 2) convert one form of energy into another.

See Also: Sensors, ADC


Showing results: 676 - 690 of 707 items found.

  • Rugged, Long Gauge Length Extensometers

    Model 3543 - Jinan Testing Equipment IE Corporation

    With over 15 years of proven reliability in the world’s most demanding testing environments, the Model 3543 extensometer is designed to survive in those applications where standard axial extensometers would not. Designed by Epsilon, the Model 3543 was created to survive specimen failure by separating into two halves, thus preventing permanent damage to the module body. During operation, the upper half of the extensometer pulls out of the main body. Tapered measuring beams activate strain gaged flexures within the unit. This unique design allows long measuring ranges, yet retains compatibility with electronics for strain gaged transducers. These models offer high accuracy and are light weight but rugged, with low operating force. They are tension only units.The units have hardened tool steel knife edges. Standard quick attach wires provided with the extensometer work on flat specimens up to 12 x 31 mm (0.5 x 1.25 inch) and on rounds up to 25 mm (1 inch) diameter. Optional quick attach kit wire forms are available for use on larger samples. See Model 3542L for long gauge lengths with smaller measuring ranges.The Model 3543 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.

  • CORROSION GAUGE

    MVX - Dakota Ultrasonics

    The MVX finishes the line of MX gauges with class. This thing is loaded with all of the features of the MX gauges and a lot more. Four selectable display options: RF, Rectified, B-Scan, and Large Digits. An internal data logger that stores a total of 12,000 readings and waveforms, 64 user custom definable setups, selectable transducer table for improved linearity, thru paint mode with the single press of a button, multiple calibration and material selection options, and auto waveform find just to mention a few! Equipped with a single element flaw prove-up mode for basic angle beam inspections. This is all nicely packaged in a very mini portable aluminum extrusion for extra durability and portability! The MVXview java-based PC software makes this thing a complete kit, and then some!

  • Universal Signal Conditioner

    Model UDA - tecsis LP

    Model UDA is a universal signal conditioner and amplifier designed for use with all full bridge, strain gage-based transducers. Model UDA turns the analog signal into a user-selectable output of ±5Vdc, ±10Vdc, or 4-20mA. This versatile unit features selectable excitation of 2.5 or 5.0Vdc bridge voltage and has a wide DC power input range from 11 to 28Vdc to adapt to a variety of installations. Model UDA includes a wide zero and span adjustment range and a symmetry adjustment for applications requiring precision in both tension and compression. The configurable low pass filter actively removes unwanted high frequency signal components. The unit is housed in a rugged DIN-mountable enclosure with screw terminals to provide connection for power, analog output, shunt calibration, and sensor signals.

  • PXIe-4480, 1.25 MS/s, 3.4 Hz AC/DC-Coupled, 6-Input PXI Sound and Vibration Module

    784277-01 - NI

    1.25 MS/s, 3.4 Hz AC/DC-Coupled, 6-Input PXI Sound and Vibration Module—The PXIe‑4480 is designed for high-bandwidth audio, acoustic, and vibration measurements. It provides six channels of dynamic signal acquisition, and you can use one of four gain settings to configure your input range. The PXIe‑4480 also includes software-configurable AC/DC coupling, charge measurement, voltage excitation, IEPE excitation, and TEDS support, making it ideal for measuring acoustic transducers, pressure sensors, and hydrophones. Common applications include audio test; noise, vibration, and harshness (NVH) analysis; and underwater acoustic measurements. For measuring sudden changes, such as high speed blast and pressure events, the PXIe-4480 can sample up to 20 MS/s per channel in time-domain mode.

  • Ensure Accurate Screening, Diagnosis & Monitoring

    Ultrasound QA Solutions - Sun Nuclear Corp.

    Gammex is the only ultrasound QA solutions manufacturer with expertise in medical physics since 1969.The 156 phantom helped establish the mammography repeatability and reproducibility standard: any mammography technologist (radiographer) at any time, on any machine, can provide the same image set to help detect breast cancer.We collaborated with clinical and academic thought leaders to develop our patented HE Gel and the first portable Doppler Flow phantoms in the world. HE (High Equivalency) Gel is what sets Gammex ultrasound products apart; it helps ensure all your transducers and system settings are fully tested across the entire frequency range from 2 to 18 MHz. Our HE Gel combined with our medical physics and quality control expertise gives you confidence with consistent diagnostic image quality in clinical applications.

  • Ultrasonic & Mass Flow Meters

    GAO Tek Inc.

    GAOTek offers high quality, affordable, secure and accurate Ultrasonic Flow Meters for sale to the United States, Canada and globally. Ultrasonic Flow Meters often have a sending and a receiving transducer for measuring the velocity of fluids to accurately calculate the flow of volume in a pipe by using sound waves, acoustic waves or vibrations with a frequency of >20 KHz. GAOTek offers a variety of top-notch Ultrasonic Flow Meters designed for different environments, from wide pipes to an all liquid environment, such as sea water, oil, sewage, alcohol, et al. GAOTek’s easy to use Ultrasonic Flow Meters come with a built-in printer and a built-in data logger. They provide accurate readings and have an accuracy rate of ±1% at rates greater than 0.2mps. They also offer multi-language menu selections, long lasting battery life for continuous usage, large LCD screens, and a huge storage.

  • Axial Clip-On Extensionmeters for Cable

    Instron

    Rugged design extensometer for axial tensile testing of stranded wire requiring a long gage length device and the ability to measure axial elongation accurately on a specimen that twists when pulled. This design allows long measuring ranges, yet retains compatibility with electronics for strain gaged transducers. Meets existing ASTM class B-2 and ISO 9513, class 0,5 requirements for accuracyDuring operation, the upper half of the extensometer pulls out of the main body. Tapered measuring beams activate strain gaged flexures within the unit. The units have hardened tool steel knife edges that are easily replaced. Quick attach kit (included) allows easy one hand mounting on specimen. Removal of the extensometer from the specimen prior to fracture, to avoid damage to the instrument, is strongly recommended.Type of Loading: static tension Specimen Material: alloy steel Specimen Types: stranded cable

  • Force Limited Vibration Testing

    National Technical Systems

    In vibration testing of high value aerospace hardware, over testing of light, high performance structures is a great concern. Discrepancies between the mechanical impedances and the force capabilities of the mounting structure and the vibration shaker can cause catastrophic structural and functional problems to test item. The effectiveness of the radar depends on it retaining its structural integrity over the entire surface of the antenna and that all its electronics are a) tested at, or near levels they will experience in its service life and b) the resonance of various parts of the radar follow those of the model. Consequently, the vibration test lab required 60 data channels to accurately verify the design of the instrument and its ability to withstand launch, cruise and deployment loads. To avoid over testing, NTS used Force Limiting Test Process using four force transducers to prevent exceeding total load of 1000 pounds.

  • DC Power Analyzer, Modular, 600 W, 4 Slots

    N6705C - Keysight Technologies

    The N6705C DC Power Analyzer provides unrivaled productivity gains for sourcing and measuring DC voltage and current into the DUT by integrating up to 4 advanced power supplies with DMM, Scope, Arb, and Data Logger features. The N6705C eliminates the need to gather multiple pieces of equipment and create complex test setups including transducers (such as current probes and shunts) to measure current into your DUT. The DC Power Analyzer also eliminates the need to develop and debug programs to control a collection of instruments and take useful measurements because all functions and measurements are available at the front panel. For even greater control and analysis functions, the DC Power Analyzer can be used with the 14585A Control and Analysis Software. When automated bench setups are required, the N6705C is fully programmable over GPIB, USB, LAN and is LXI Compliant. 14585A Control and Analysis Software

  • Multifunction Calibrator 15 ppm Basic Accuracy

    MC142 - Powertek LLC

    Multifunction calibrator MC142 is a precision voltage, current and power calibration source serving as a measurement standard in calibration laboratories and production lines; where verification of electrical measurement equipment & sensors is required. It can be used for calibration and adjustment of meters measuring voltage, current, power, resistance, capacitance and frequency. Internal harmonic and non-harmonic signals make it possible to test electrical performance of meters using signals with various crest factors. Frequency modes enable selection of frequency, amplitude and duty cycle of the output signal. These are suitable for basic calibration of digital and analog oscilloscopes along with transient recorders. The calibrator is equipped to measure temperature with TC and RTD temperature sensors. Its built-in multimeter can be used independently or simultaneously with the calibrator output. Testing of transducers of various types, regulators and sensors can be performed, without the necessity to use any other measuring instrument.

  • 8/16-CH 16-Bit Analog Output Cards

    PCI-6208/6216 Series - ADLINK Technology Inc.

    ADLINK PCI-6208/6216 series are 8 or 16-CH, 16-bit, analog output cards. The PCI-6208V-GL offers 8 voltage outputs with ±10 V range, featuring 15-bit monotonicity and 10 V/μs slew rate. The on-board analog switches minimize the power-on glitches. PCI-6216V expands the voltage output channels to a total of 16 for higher analog output density requirements. In addition to the voltage output functions, the PCI-6208A features 8 current outputs with ranges of 0-20 mA, 4-20 mA, and 5-25 mA. The daughter board EXP-8A provides high-quality voltage to current transducers. The PCI-6208A device is capable of delivering 14-bit monotonicity with 1.3 mA/μs slew rate. ADLINK PCI-6208 series devices provide high-resolution, high-density analog output functionalities and are suitable for ATE, signal generation, industrial process control, servo control and other industrial control applications.

  • Life Cyclic Durability Testing

    Environment Associates Inc.

    Environment Associates can provide everything you need for cyclic durability testing and performance fixturing. Services include mechanical cycling to a position or load, fatigue cycling to a fixed load, rotational torque cycling, and simple push/pull cycling. EA can design your fixture with electro-dynamic, air, or hydraulic assistance to mechanically move your part. All of our fixtures can be manufactured to withstand a wide range of temperature, humidity and vibration inputs. If required, forces can be monitored electronically, using a wide variety of inputs (i.e. strain gages, load cells, rotational transducers, thermocouples, shunts, and more). EA can create holding and check fixtures to perform “pre” and “post” evaluation for dimensional issues that may occur during testing. EA can provide fixtures for single tests run internally for EA test labs and can manufacture fixtures to be purchased directly by the customer for their internal use.

  • Circuit Breaker Analyzers & Timers

    CAT Advanced Series - IBEKO Power AB

    DV Power circuit breaker analyzer and timer utilizes the latest technological enhancements for safe and fast testing of circuit breakers. The sophisticated design ensures efficient and reliable operations in high-voltage substations and industrial environments.The CAT Advanced series are stand-alone or PC-controlled digital instruments for a circuit breaker testing. The timing channels record closing and an opening of the arcing, resistor, and auxiliary contacts. Also, the main contact channels can measure the resistance value of the pre-insertion resistors (if present in the circuit breaker).With CAT Advanced series instruments, it is possible to record graphs of open and close coil currents. Furthermore, it records displacements of the HV and MV circuit breaker moving parts. Test results can be saved via USB, PC or be printed via 112 mm (4.4 inches) thermal printer (optional accessory) in tabular and graphical form.A circuit breaker test consists of different operational modes and CAT Advanced series supports:Open (O)Close (C)Reclose (O-0,3s-C)Trip free (CO)O-0,3s-COOpen-Close (O-C)Close-Open (C-O)Open-Close-Open (O-C-O)First trip (O)Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by sensing a breaker’s contact position.The auxiliary inputs are used to monitor dry and wet auxiliary contacts. The six coil control analog channels measure and record coil currents simultaneously (OPEN and CLOSE), up to 35 A AC/DC.The additional six voltage analog channels have four selectable voltage ranges available (±1 V, ±5 V, ±60 V and ±300 V AC/DC).A built-in micro-ohmmeter generates up to 500A true DC ripple-free current with an automatically regulated test ramp that provides performing static and dynamic contact resistance measurement.Three transducer channels provide a measuring displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time and average velocity. Also, a user can connect either an analog or a digital transducer to these universal channels.

  • C Series Digital Module

    NI

    The C Series Digital Module interacts with a range of industrial switches, transducers, and devices. Some modules include an LED per channel that indicates the state of the channel. It supports input, output, or a combination of digital lines, and they can interact with a variety of voltages and logic levels, so they are well-suited for a variety of benchtop and industrial environments. Additionally, the C Series Digital Module also offers isolation options and sinking or sourcing capabilities to add further protection to your digital I/O application. When you use the C Series Digital Module with CompactRIO, you can use LabVIEW FPGA to create custom high-speed counter/timers, digital communication protocols, pulse generation, and more.The C Series Digital Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.

  • 6000 Series Digital I/O Modules

    Pacific Instruments, Inc.

    Series 6000 digital I/O modules record signals from frequency counters, flow meters, encoders, discrete transducers, IRIG time, etc. which are often part of the test environment. These digital signals are time aligned and recorded alongside the system’s analog measurements. High density digital inputs provide an opportunity to easily include facility controls like switches, valve positions, relays, lights, etc. along with the test data. Series 6000 digital I/O modules also provide outputs generated by user command or automatically by Sequence, Alarms or DSP. User generated outputs are accomplished in software while sequencers can be programmed prior to a test and initiated by program or hardware control. Alarm conditions preprogrammed on the analog side can automatically generate digital outputs which are typically connected to facility control systems or PLCs. A DSP adds powerful real-time processing and is appropriate for PID control loops, derived parameter calculations and a variety of other real-time operations.