Showing results: 31 - 45 of 49 items found.
-
Hanna Instruments, Inc.
Automated titration for dairy can mean simplicity with a dedicated mini-titrator or a parameter encompassing fully-automated instrument. Whether milk, yogurt, or cheese - our fully supported automatic titrators will provide the safeguard you need.
-
LD-LAAT-A13 -
Labodam
LabodamLD-LAAT-A13is composed of automatic potential titrator and titration device. It is designed according to Industry Standard of Petrochemical and follows ASTM D2896 and ASTM D4739 Test Methods for Base Number of Petroleum Products.
-
NUL-238 -
Neulog
The NeuLog calcium sensor enables measurements of ionic calcium (Ca2+) concentration in aqueous samples. This measurement is very important when evaluating water quality. It can also be used to determine calcium magnesium by EDTA titration.
-
134S -
Elcometer Limited
Elcometer 134S test method: a latex sleeve is filled with a Chlor*Rid extract solution and stuck to the test surface where the solution is worked against the surface to extract the salts. The titration tube is inserted and the results can be recorded.
-
Vapor Pro® XL -
Ametek Brookfield
Improved repeatability, precision, flexibility and an advanced user interface – the Vapor Pro® XL is the latest in moisture specific analysis technology from Computrac®. The VPXL is ideal for nearly any application in which Karl Fischer titration is used.
-
Model 6800T -
Teledyne Analytical Instruments
The 6800T Series Analyzers are a family of on-line sequential sampling analyzers that use various automated analytical technologies to perform an analysis. When configured for alkalinity measurements, titration technology is used for the most cost effective, ease of use and low maintenance method.
-
XL Autosampler -
Ametek Brookfield
The Vapor Pro XL (VPXL) Autosampler is the latest in moisture-specific analysis technology offering accuracy, precision, flexibility, and automation to test up to 16 samples with individual test profiles. The VPXL Autosampler’s advanced moisture analysis capabilities make it a chemical-free alternative to Karl Fischer titration.
-
DRK-K616 -
Shandong Drick Instruments Co., Ltd.
The DRK-K616 Automatic Kjeldahl Nitrogen Analyzer is a fully automatic distillation and titration nitrogen measurement system designed based on the classic Kjeldahl nitrogen determination method. The core control system of DRK-K616, as well as the automatic machine and spare parts for perfection, create the excellent quality of DRK-K616.
-
KEM
Large color TFT-LCD with a touch panel (8.4-inch) enables easy key entry.Up to 4 titrators, MKV-710B Volumetric, MKC-710B Coulometric or MKH-710/2nd Hybrid Karl Fischer moisture titrators or additional AT-710B potentiometric titrators, can be connected and simultaneous measurement is possible.Monitoring temperature during titration ensures safe measurements.
-
Model N500 -
Teledyne Advanced Pollution Instrumentation
The Model N500 CAPS NOx analyzer uses superior Cavity Attenuated Phase Shift (CAPS) Spectroscopy to measure True NO2, NOx, and NO gases. The instrument combines direct NO2 measurements with highly efficient gas phase titration (GPT) to convert and measure the NO gas component. An automatic baseline reference cycle accounts and compensates for any potential baseline drift due to varying environmental conditions.
-
Labfon Equipment Inc.
Karl Fischer titration is widely used for direct analysis of water content in various industries, as a reliable and healthy method. In food industry it is used for water content determination in fruit juices, honey where as it is needed in petroleum industry to check the water content in different oils, also in cosmetic industry for determination of water in the products. It is required in pharmaceutic industry for raw materials, active substances, lyophilized substrates, tablets, ointments, oils.
-
Hach Lange GmbH
The single parameter test kits make it easy to determine specific parameters on site or in the laboratory. Different platforms offer a range of options - from easy-to-use, inexpensive drop count titration to high-precision digital titrator kits. Hach test kits include everything you need to get started with your determinations right away. This includes the necessary equipment and a complete set of reagents, all in a sturdy Hach transport case.
-
NuVant Systems, Inc.
Our electrochemical equipment will help your group achieve laboratory and research goals. The best-selling EZstat Pro potentiostat/galvanostat can run cyclic voltammetry, electrochemical impedance spectroscopy (EIS), battery tests, and high speed galvanostatic intermittent titration technique (GITT). The EZstat HV potentiostat delivers up to 1 amp at 25 volts. The Powerstat comes in two configurations (5 amp vs 20 amp). The Duostat bipotentiostat can operate rotating ring-disk electrode experiments. The Arraystat and ArrayPGstat feature multichannel operation with different customizable options (current range, number of channels, etc.).
-
Shimadzu Corp.
Analyzing moisture, and how much of it, is critical to the performance of petroleum products, as well as infrastructure and product integrity. For example, moisture in petrochemical feedstock can cause pipelines and valves to freeze, as well as poison some catalysts. One popular method used to analyze for moisture is Karl Fischer Titration (KFT). KFT has a wide dynamic range but has difficulty in measuring relatively low amounts of moisture. In addition, there are the well-known problems of side reactions and known interferences.
-
AcoustoSizer II -
Colloidal Dynamics, LLC
The new AcoustoSizer IIs provides thorough characterization of concentrated colloidal dispersions. Directly measuring particle size, zeta potential, pH, conductivity, and temperature, it furnishes the most comprehensive analysis available in a single, turnkey instrument. Based on a flow-through sensor design, the AcoustoSizer IIs can be used in a laboratory batch analysis mode or connected directly to a process slipstream. Built-in syringe pumps provide automated potentiometric and volumetric titration capabilities for accurate isoelectric point and surfactant addition determination.