Filter Results By:

Products

Applications

Manufacturers

Showing results: 1726 - 1740 of 5355 items found.

  • Automated Handler

    Model 900 Series - Dataman, Inc

    The Model 900 Series is a versatile handler by Exatron which automates programming, marking and inspection of devices in tape, tube and JEDEC trays. Model 900 utilises the latest Dataman universal programmers to offer super-fast programming and support for over 70,000 devices • Virtually “kit-less” - quick and easy changeover of Dataman socket adapters and pickup head tips • 1,000 UPH (with 10 sec. program time) • Moves 1 device at a time • 4 programming sockets, expandable to 8 (requires longer gantry) • 1 input/output JEDEC tray (up to 6 trays available) • Optional tube and/or tape input/output • Optional top and/or bottom-side vision • Optional laser marking • Dataman and Exatron software integrate seamlessly • CE marked • Small footprint

  • Flatness, Bow, Warp, Curvature, Glass Thickness

    1D-glass Thickness Profile Measuring Instrument GPM2 - Optik Elektronik Gerätetechnik GmbH

    Highly accurate automatic measurement of glass thickness distributions. The glass thickness profiler GPM has the function to execute a fast and precise determination of the thickness profile of flat glass samples or another transparent material with a thickness range from 30µm to 700µm (option with sensor type 1) and width to 1200mm. The measuring point distance of the profile measurement can be varied over a micro-step-controlled positioning steering between 0.1mm and 1mm. The measured value accommodation for a scanning point takes place with the help of a special hardware module for image processing algorithms within 40 ms. The entire measuring time for a sample results thus as product from the sample width which has to be measured, the measuring point distance and the measuring time per measuring point.

  • Oscilloscopes

    Extech Instruments Corporation

    A Digital Oscilloscope offers a range of capabilities for effective troubleshooting of electronics and electronically controlled electrical systems. With 20 MHz bandwidth and conveniences like auto-set which optimizes the position, range, time base, and triggering to assure a stable display of virtually any waveform, this can be used in field repairs or bench duty. To identify subtle problems, Peak Detect features a fast 50 ns glitch capture. Core functions like XY Mode, FFT function, Trigger Hold off, Waveform Math, Averaging Mode and Persistence Mode all ensure you can confidently troubleshoot problems using a variety of approaches. To start up recurring testing routines, you can store and recall up to 4 waveform screens and setups to save time from job to job.

  • SparkFun Distance Sensor

    1.3 Meter, VL53L4CD (Qwiic) - SparkFun Electronics

    This SparkFun Distance Sensor Breakout utilizes the VL53L4CD next generation ToF (Time of Flight) sensor module to give you the highly accurate measurements at short ranges for its size. The VL53L4CD from STMicroelectronics uses a VCSEL (Vertical Cavity Surface Emitting Laser) to emit an infrared laser to time the reflection to the target. That means that you will be able to measure the distance to an object from 1mm to 1300mm away with millimeter resolution! To make it even easier to get your readings, all communication is enacted exclusively via I2C, utilizing our handy Qwiic system so no soldering is required to connect it to the rest of your system. However, we still have broken out 0.1”-spaced pins in case you prefer to use a breadboard.

  • SparkFun Distance Sensor Breakout

    4 Meter, VL53L1X (Qwiic) - SparkFun Electronics

    This SparkFun Distance Sensor Breakout utilizes the VL53L1X next generation ToF (Time of Flight) sensor module to give you the highly accurate measurements at long ranges for its size. The VL53L1X from STMicroelectronics uses a VCSEL (Vertical Cavity Surface Emitting Laser) to emit an Infrared laser to time the reflection to the target. That means that you will be able to measure the distance to an object from 40mm to 4m away with millimeter resolution! To make it even easier to get your readings, all communication is enacted exclusively via I2C, utilizing our handy Qwiic system so no soldering is required to connect it to the rest of your system. However, we still have broken out 0.1”-spaced pins in case you prefer to use a breadboard.

  • Integrated Video Management System

    iVMS - IneoQuest

    The iVMS iQ Engines provide that comprehensive view of your FoQus platform assets. Management systems are available for Linear/IPTV networks (iVMS) or adaptive bitrate networks (iVMS ASM). iVMS tracks QoE and QoS data for thousands of programs across hundreds of acquisition elements to provide true end-to-end, centralized video quality management. With iVMS, you can drill down to identify and isolate the root cause of issues by program, time and location. In order to reduce repair time (MTTR), iVMS can send alert notifications via email to technicians, operations, and engineering staff, and can present collected information to OSS/BSS systems via a northbound interface. iVMS also collects and stores statistics, supporting historical network performance analysis in addition to its real-time capabilities.

  • PCIe 16 Bit Multi-purpose Digitizer - up to 5 MS/s on 4 Channels (Single Ended) or 4 Channels (Differential)

    M2P.5916-X4 - Spectrum Instrumentation

    The M2p.59xx series allows recording of up to eight single-ended channels or up to four differential channels both with sampling rates of up to 125 MS/s. These PCI Express cards offer outstanding A/D features both in resolution and speed. The cards can be switched between single-ended inputs with a programmable offset and true differential inputs. If used in differential mode each two inputs are connected together reducing the number of available channels by half. The 16 bit vertical resolution have four times the accuracy compared to 14 bit cards and sixteen times the accuracy if compared with a 12 bit card. All boards of the M2p.59xx series may use the whole installed on-board memory of up to 512 MSamples completely for the currently activated number of channels.

  • PCIe 16 Bit Multi-purpose Digitizer - up to 5 MS/s on 2 Channels

    M2P.5911-X4 - Spectrum Instrumentation

    The M2p.59xx series allows recording of up to eight single-ended channels or up to four differential channels both with sampling rates of up to 125 MS/s. These PCI Express cards offer outstanding A/D features both in resolution and speed. The cards can be switched between single-ended inputs with a programmable offset and true differential inputs. If used in differential mode each two inputs are connected together reducing the number of available channels by half. The 16 bit vertical resolution have four times the accuracy compared to 14 bit cards and sixteen times the accuracy if compared with a 12 bit card. All boards of the M2p.59xx series may use the whole installed on-board memory of up to 512 MSamples completely for the currently activated number of channels

  • PCIe 16 Bit Multi-purpose Digitizer - up to 125 MS/s on 2 Channels (Single Ended) or 2 Channels (Differential)

    M2P.5961-X4 - Spectrum Instrumentation

    The M2p.59xx series allows recording of up to eight single-ended channels or up to four differential channels both with sampling rates of up to 125 MS/s. These PCI Express cards offer outstanding A/D features both in resolution and speed. The cards can be switched between single-ended inputs with a programmable offset and true differential inputs. If used in differential mode each two inputs are connected together reducing the number of available channels by half. The 16 bit vertical resolution have four times the accuracy compared to 14 bit cards and sixteen times the accuracy if compared with a 12 bit card. All boards of the M2p.59xx series may use the whole installed on-board memory of up to 512 MSamples completely for the currently activated number of channels.

  • PCIe 16 Bit Multi-purpose Digitizer - up to 5 MS/s on 4 Channels (Single Ended) or 2 Channels (Differential)

    M2P.5912-X4 - Spectrum Instrumentation

    The M2p.59xx series allows recording of up to eight single-ended channels or up to four differential channels both with sampling rates of up to 125 MS/s. These PCI Express cards offer outstanding A/D features both in resolution and speed. The cards can be switched between single-ended inputs with a programmable offset and true differential inputs. If used in differential mode each two inputs are connected together reducing the number of available channels by half. The 16 bit vertical resolution have four times the accuracy compared to 14 bit cards and sixteen times the accuracy if compared with a 12 bit card. All boards of the M2p.59xx series may use the whole installed on-board memory of up to 512 MSamples completely for the currently activated number of channels.

  • PCIe 16 Bit Multi-purpose Digitizer - up to 125 MS/s on 4 Channels (Single Ended) or 4 Channels (Differential), up to 80 MS/s on 8 Channels (Single Ended)

    M2P.5968-X4 - Spectrum Instrumentation

    The M2p.59xx series allows recording of up to eight single-ended channels or up to four differential channels both with sampling rates of up to 125 MS/s. These PCI Express cards offer outstanding A/D features both in resolution and speed. The cards can be switched between single-ended inputs with a programmable offset and true differential inputs. If used in differential mode each two inputs are connected together reducing the number of available channels by half. The 16 bit vertical resolution have four times the accuracy compared to 14 bit cards and sixteen times the accuracy if compared with a 12 bit card. All boards of the M2p.59xx series may use the whole installed on-board memory of up to 512 MSamples completely for the currently activated number of channels.

  • PCIe 16 Bit Multipurpose Digitizer - up to 40 MS/s on 4 Channels (Single Ended) or 2 Channels (Differential)

    M2P.5932-X4 - Spectrum Instrumentation

    The M2p.59xx series allows recording of up to eight single-ended channels or up to four differential channels both with sampling rates of up to 125 MS/s. These PCI Express cards offer outstanding A/D features both in resolution and speed. The cards can be switched between single-ended inputs with a programmable offset and true differential inputs. If used in differential mode each two inputs are connected together reducing the number of available channels by half. The 16 bit vertical resolution have four times the accuracy compared to 14 bit cards and sixteen times the accuracy if compared with a 12 bit card. All boards of the M2p.59xx series may use the whole installed on-board memory of up to 512 MSamples completely for the currently activated number of channels.

  • PCIe 16 Bit Multi-purpose Digitizer - up to 125 MS/s on 4 Channels (Single Ended) or 2 Channels (Differential)

    M2P.5962-X4 - Spectrum Instrumentation

    The M2p.59xx series allows recording of up to eight single-ended channels or up to four differential channels both with sampling rates of up to 125 MS/s. These PCI Express cards offer outstanding A/D features both in resolution and speed. The cards can be switched between single-ended inputs with a programmable offset and true differential inputs. If used in differential mode each two inputs are connected together reducing the number of available channels by half. The 16 bit vertical resolution have four times the accuracy compared to 14 bit cards and sixteen times the accuracy if compared with a 12 bit card. All boards of the M2p.59xx series may use the whole installed on-board memory of up to 512 MSamples completely for the currently activated number of channels.

  • PCIe 16 Bit Multi-purpose Digitizer - up to 40 MS/s on 8 Channels (Single Ended) or 4 Channels (Differential)

    M2P.5933-X4 - Spectrum Instrumentation

    The M2p.59xx series allows recording of up to eight single-ended channels or up to four differential channels both with sampling rates of up to 125 MS/s. These PCI Express cards offer outstanding A/D features both in resolution and speed. The cards can be switched between single-ended inputs with a programmable offset and true differential inputs. If used in differential mode each two inputs are connected together reducing the number of available channels by half. The 16 bit vertical resolution have four times the accuracy compared to 14 bit cards and sixteen times the accuracy if compared with a 12 bit card. All boards of the M2p.59xx series may use the whole installed on-board memory of up to 512 MSamples completely for the currently activated number of channels.

  • PCIe 16 Bit Multi-purpose Digitizer - up to 80 MS/s on 2 Channels (Single Ended) or 2 Channels (Differential)

    M2P.5941-X4 - Spectrum Instrumentation

    The M2p.59xx series allows recording of up to eight single-ended channels or up to four differential channels both with sampling rates of up to 125 MS/s. These PCI Express cards offer outstanding A/D features both in resolution and speed. The cards can be switched between single-ended inputs with a programmable offset and true differential inputs. If used in differential mode each two inputs are connected together reducing the number of available channels by half. The 16 bit vertical resolution have four times the accuracy compared to 14 bit cards and sixteen times the accuracy if compared with a 12 bit card. All boards of the M2p.59xx series may use the whole installed on-board memory of up to 512 MSamples completely for the currently activated number of channels.

Get Help