  • Type-K Pipe Clamp Temperature Probe (-4 to 200°F)

    Extech TP200 - Extech Instruments Corporation

    The Extech TP200 Type-K Pipe Clamp Temperature Probe produces a hands-free, super heat and sub cooling temperature measurement. The spring-loaded jaw ensures a secure grip on pipes from 6.35 mm (0.25 in) to 38 mm (1.5 in) in diameter. This probe can be used with any thermometer or multimeter with a Type-K thermocouple input. The measurement range is from -20°C to 93°C (-4°F to 200°F) with and accuracy of ±1.8°C (3.6°F). The TP200 comes complete with an attached 0.9 mm (36 in) cable and a Type-K connector.

  • sbRIO-9219, Non-Enclosed, 100 S/s/channel, 4-Channel C Series Universal Analog Input Module

    781027-01 - NI

    Non-Enclosed, 100 S/s/channel, 4-Channel C Series Universal Analog Input Module - The sbRIO‑9219 is designed for multipurpose testing. With the sbRIO‑9219, you can measure signals from sensors such as strain gages, resistance temperature detectors (RTDs), thermocouples, load cells, and other powered sensors, as well as make quarter-bridge, half-bridge, and full-bridge current measurements, with built-in voltage and current excitation. Each channel is individually selectable, so you can perform a different measurement type on each channel. Non-enclosed modules are designed for OEM applications.

  • BNC-2120, 68-Pin Female SCSI to Female BNC and Screw Terminal, DIN Rail, Desktop Mount, Shielded Terminal Block

    777960-01 - NI

    68-Pin Female SCSI to Female BNC and Screw Terminal, DIN Rail, Desktop Mount, Shielded Terminal Block - The BNC-2120 can be used with various NI multifunction I/O and analog output devices. The BNC-2120 simplifies the connection of analog signals, some digital signals, and two user-defined connections to the data acquisition device while maintaining the integrity of your measurements with a shielded enclosure. It also features a function generator, quadrature encoder, and cold junction compensation for thermocouple measurements. The BNC-2120 includes a DIN Rail and a desktop mount option.

  • Multiplexed- Low-Level Function Card

    Neff Instrument Corporation

    Low-level multiplexed systems have a single programmable gain, wide-band amplifier following the input multiplexer. To accommodate low-level signal signals such as those from strain gauges or thermocouples and at the same time high level signals from other sources, the throughput rate must be limited to enable the high bandwidth amplifier to settle to the correct value after switching to a new channel. This results in a relatively low aggregate throughput rate when compared to an amplifier-per-channel system. A major benefit of a well designed low-level multiplexed system is the extremely high performance/cost relationship.

  • Datapaq Solar Tracker System

    Fluke Process Instruments

    The SolarPaq® Thermal Profiling Systems from Fluke Process Instruments are designed specifically for solar photovoltaic (PV) manufacturing including applications like contact firing, contact drying, anti-reflection coating for the solar cell, lamination and other thin film processes. These systems, consisting of user-friendly Insight™ software, Datapaq® Q18 data loggers, stainless steel thermal barriers, thermocouples with PTFE or mineral insulation and accessories, provide users with the tools needed to gather accurate, repeatable results for process optimization, maximize cell efficiency and throughput, and more.

  • LXI Low Thermal EMF Matrix 1-pole 56x33

    60-510-001 - Pickering Interfaces Ltd.

    The 60-510 is a high density 1-pole matrix module controlled via LXI. It has excellent thermal stability and substantially reduced thermal EMF figures when compared to a conventional switching matrix. Typical applications include signal routing in ATE, selecting thermocouple inputs, switching amplifier gain circuits and high accuracy DC micro-volt measurements. Ruthenium reed switches are used because of their good low level switching capability. They also have a very long life with excellent contact resistance stability, minimal wetting current and low thermal offset.

  • LXI Low Thermal EMF Matrix 1-pole 44x33

    60-510-021 - Pickering Interfaces Ltd.

    The 60-510 is a high density 1-pole matrix module controlled via LXI. It has excellent thermal stability and substantially reduced thermal EMF figures when compared to a conventional switching matrix. Typical applications include signal routing in ATE, selecting thermocouple inputs, switching amplifier gain circuits and high accuracy DC micro-volt measurements. Ruthenium reed switches are used because of their good low level switching capability. They also have a very long life with excellent contact resistance stability, minimal wetting current and low thermal offset.

  • LXI Low Thermal EMF Matrix 1-pole 28x33

    60-510-003 - Pickering Interfaces Ltd.

    The 60-510 is a high density 1-pole matrix module controlled via LXI. It has excellent thermal stability and substantially reduced thermal EMF figures when compared to a conventional switching matrix. Typical applications include signal routing in ATE, selecting thermocouple inputs, switching amplifier gain circuits and high accuracy DC micro-volt measurements. Ruthenium reed switches are used because of their good low level switching capability. They also have a very long life with excellent contact resistance stability, minimal wetting current and low thermal offset.

  • Thermostation

    VT-96 - Holding Informtest

    Thermal station VT-96 is intended for building data collection systems (distributed and remote) from thermocouple temperature sensors. The interfaces allow you to easily and quickly connect the VT-96 to a remote (via ETHERNET) or nearby computer (via USB). The integrated WEB-page provides a convenient way to check the communication with the unit and its functioning, and the standard VXIplug & play drivers reduce the costs of integrating the unit into the system and developing application software. Multiple thermostats easily integrate and synchronize with each other and other VXI instruments via a dedicated Trigger Bus.

  • Semiconductor Package Wind Tunnel

    WT-100 - Thermal Engineering Associates, Inc.

    The WT-100 Forced Convection (Moving Air) Wind Tunnel is designed in accordance with the EIA/JEDEC JESD51-6 standard for thermal characterization of semiconductor packages and devices. The vertical design minimizes laboratory floor space requiements. Air is drawn in at the bottom and exhausts at the top. The test section is large enough to accommodate the largest JEDEC and SEMI thermal test boards. Air velocity can be adjusted over the range of 0.5 to 5 m/s; air velocity is monitored with an included hot-wire anemometer connected to a digital display. A Type-T thermocouple is mounted in the test section for monitoring the moving air temperature.

  • NI-9212, 8-Channel, 95 S/s/ch Simultaneous, ±78 mV C Series Temperature Input Module

    782975-01 - NI

    8-Channel, 95 S/s/ch Simultaneous, ±78 mV C Series Temperature Input Module - The NI‑9212 offers channel‑to‑channel, isolated thermocouple input channels. The NI‑9212 channel‑to‑channel isolation protects channels from continuous voltages up to 250 Vrms and transient (withstand) voltages up to 1500 Vrms. You can use the NI‑9212 in a variety of applications that are not conducive for bank-isolated channels such as white goods testing, in-vehicle data logging, battery stack testing, as well as in various other noisy industrial environments.

  • LXI Low Thermal EMF Matrix 1-pole 42x33

    60-510-002 - Pickering Interfaces Ltd.

    The 60-510 is a high density 1-pole matrix module controlled via LXI. It has excellent thermal stability and substantially reduced thermal EMF figures when compared to a conventional switching matrix. Typical applications include signal routing in ATE, selecting thermocouple inputs, switching amplifier gain circuits and high accuracy DC micro-volt measurements. Ruthenium reed switches are used because of their good low level switching capability. They also have a very long life with excellent contact resistance stability, minimal wetting current and low thermal offset.

  • NI-9213, cDAQ-9171, and cRIO-9940 USB Temperature Measurement Bundle

    865682-01 - NI

    NI-9213, cDAQ-9171, and cRIO-9940 USB Temperature Measurement Bundle - The USB Temperature Measurement Bundle with NI-9213, cDAQ-9171, and cRIO-9940 includes the NI-9213 C Series Temperature Input Module and the cDAQ-9171 CompactDAQ Chassis for voltage measurements. This bundle also includes the cRIO-9940 Backshell for strain relief and operator protection from high-voltage signals. The included NI-9213 provides noise immunity, a high common-mode voltage range, NIST-traceable calibration, differential analog inputs, and four channels. Additionally, the NI-9213 features anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements.

  • NI-9212, 8-Channel, 95 S/s/ch Simultaneous, ±78 mV C Series Temperature Input Module

    785259-01 - NI

    8-Channel, 95 S/s/ch Simultaneous, ±78 mV C Series Temperature Input Module - The NI‑9212 offers channel‑to‑channel, isolated thermocouple input channels. The NI‑9212 channel‑to‑channel isolation protects channels from continuous voltages up to 250 Vrms and transient (withstand) voltages up to 1500 Vrms. You can use the NI‑9212 in a variety of applications that are not conducive for bank-isolated channels such as white goods testing, in-vehicle data logging, battery stack testing, as well as in various other noisy industrial environments.

  • LXI And LXI/USB Modular Chassis

    Pickering Interfaces Ltd.

    Our LXI modular chassis are available in 7 and 18-slot and our LXI/USB modular chassis are available in 2, 4 and 6-slot and support over 1,000 of our PXI modules. The PXI modules supported range from: PXI general purpose relays, matrices, multiplexers and RF switches to special PXI switching functions such as fault/signal insertion. Also supported are a selection of simulation modules such as programmable resistors, digital I/O, power supplies, thermocouple simulators, function generator, battery simulators and attenuators. This gives you enormous flexibility to define a switching or T&M system to exactly match your needs.

Get Help