  • sbRIO-9211, Non-Enclosed, 4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module

    780877-01 - NI

    Non-Enclosed, 4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module - The sbRIO‑9211 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The sbRIO‑9211 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.

  • C Series Universal Analog Input Module

    NI

    The C Series Universal Analog Input Module helps you perform multi-purpose measurements. This module includes built-in support for accelerometer, powered sensor, full-bridge, and voltage measurements as well as quarter-bridge, half-bridge, 60 V, and current measurements using measurement-specific adapters. You also can choose options to measure signals from sensors such as strain gages, resistance temperature detectors (RTDs), thermocouples, load cells, and other powered sensors.The C Series Universal Analog Input Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.

  • PLC Input Modules

    Datexel

    The DATEXEL DAT6000 series is a unique device designed to add analog inputs to a digital PLC with a few simple instructions. Downloaded into a standard PLC it is possible to acquire analog signals. The PLC will be able to read a 16 Bit digital input equal to the analog signal. The input, output and power supply are isolated from each other. The DAT6000 can linearize , filter and convert the input signal.The DATEXEL DAT6011 converts two voltages -50 mV to 50 mV, -100 mV to 100 mV, -500 mV to 500 mV or -1000mV to 1000mV or thermocouples K Type, J Type, S type, B type, R type, E type, T type and N type to a digital PLC.

  • 6 ½ Digits Dual-Display Digital Multimeters

    SDM3065X - SIGLENT Technologies

    The SIGLENT SDM3065X-SC includes a multiplexer that provides multi-point measurement capabilities. The scanner features 12 multi-purpose + 4 current channels and supports the following measurement functions: DCV, ACV, DCI, ACI, 2WR, 4WR, CAP, FREQ, DIODE, CONT and TEMP ( RTD and Thermocouple ). It provides a convenient and versatile solution for test applications that require multiple measurement points or signals and is an ideal tool for R&D burn-in and production testing.

  • 5 ½ Digits Dual-Display Digital Multimeters

    SDM3055 - SIGLENT Technologies

    The SIGLENT SDM3055-SC includes a multiplexer that provides multi-point measurement capabilities. The scanner features 12 multi-purpose + 4 current channels and supports the following measurement functions: DCV, ACV, DCI, ACI, 2WR, 4WR, CAP, FREQ, DIODE, CONT and TEMP (RTD and Thermocouple ). It provides a convenient and versatile solution for test applications that require multiple measurement points or signals and is an ideal tool for R&D burn-in and production testing.

  • PTO Dynamometers

    AW Dynamometer, Inc.

    AW is the world leader in AG/PTO dynamometers with over 14,000 units sold. AW's hydraulic activated load unit is water cooled allowing it to test high torque loads for continuous periods of time. AW's heavy duty load units are well known to last for decades. Combine this with all new computerized electronic load control, software, thermocouples, sensors and you have a system second to none - the AG.X Series.

  • Digital Telemetry Solutions

    imc Test & Measurement GmbH

    For measurements on rotating components and moving machinery, imc offers modern telemetry systems for a wide variety of tasks: whether single-channel torque monitoring of a rotating shaft, multi-channel strain gauge and temperature measurements on a train wheel-set or non-contact power measurement on a vehicle drivetrain in harsh environments. There are transmission electronics available for a large variety of sensors, such as strain gauge (quarter-, half- and full-bridge), thermocouples, PT100/1000, as well as IEPE sensors and voltage signals.

  • Calibration And Verification Instruments

    ViTec Co. Ltd

    The system of automatic calibration and verification consists of a computer of the operator's workplace and a control controller with a calibrator connected to it and a verified device. The device under test can have 4 to 16 working channels with a complicated circuit for connecting different types of signals: voltage, current, thermocouples, thermoresistance. The system allows a change in the set of operating ranges during calibration and calibration. The software development system used the LabVIEW development environment with the Real-Time module.

  • Multifunction Process Calibrator

    Extech 412400 - Extech Instruments Corporation

    The Extech 412400 Multifunction Process Calibrator sources and measures thermocouples (J, K, and T), mA, mV, and V devices. The 24 V loop supply drives current loads up to 1000 ohms. It has memory for 5 user-settable output values of each type for fast calibrations. Single and continuous step function for voltage and current. Comes complete with six AA batteries and a calibration cable with spade lug terminals.

  • Custom Engineered Sensors

    Electronic Development Labs, Inc.

    Since 1943, we have been known as The Temperature People. Our single focus has been on designing and manufacturing the finest temperature products available. In addition to our thousands of standard sensors, EDL offers extensive custom engineering capabilities for process measurement and control. Thermocouples, RTDs, thermistors - contact us for a customized solution based on your needs. Our versatile manufacturing and machining allows us to efficiently produce even small quantities of temperature sensors or prototypes that require specialty machined components. Our engineering team delivers the knowledge and experience to customize and develop new products for customer specific applications. Contact us at sales@edl-inc.com or 800.342.5335 for a solution to your unique temperature application.

  • Temperature Input Device

    NI

    The Temperature Input Device is a thermocouple measurement device featuring InstantDAQ technology. InstantDAQ technology includes built-in software for viewing and logging data that automatically loads when you plug in the device, so you can instantly take temperature measurements with your PC. You can connect the Temperature Input Device to any USB port to use your PC as a display and monitor data in real time. The device is compatible with J, K, R, S, T, N, E, and B thermocouples.The Temperature Input Device includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.

  • Signal Conditioning System

    28000 - Precision Filters, Inc.

    The Precision 28000 Signal Conditioning System makes it easy to manage a test with up to 256 channels of fully programmable transducer conditioning. Choose a mix of bridge, charge, IEPE w/TEDS, voltage (filter amplifier), strain, thermocouple, RTD/potentiometer, frequency, or other transducers. Self-tests traceable to NIST. 4, 8 and 16-slot rugged and transportable mainframes feature integrated cooling. Customize the 28000 for high-speed transient applications, static applications, or a combination of both.

  • High Temperature Type-K Pipe Clamp (-4 to 450°F)

    Extech TP400 - Extech Instruments Corporation

    The Extech TP400 Type-K High Temperature Pipe Clamp probe produces a hands-free, super heat, and sub cooling temperature measurement. The spring-loaded jaw is for a secure grip on pipes from 6.35 mm (0.25 in) to 38 mm (1.5 in) in diameter. This probe is for use with any thermometer or multimeter with a Type-K thermocouple input. The measurement range is from -20°C to 232°C (-4°F to 450°F) with an accuracy of ± 1.8°C (3.6°F).

  • Temperature Data Acquisition

    THERMES-USB - Physitemp Instruments

    Physitemp’s Thermes high accuracy data acquisition system has been redesigned to create a more versatile USB model. The new system requires no internal connections to your computer and simply connects via an external USB port on your laptop or desktop computer. Two versions of the data acquisition system are available. The standard version, THERMES USB, is connected to your computer USB port. The wireless version - THERMES USB WFI, can be either directly connected to a USB port or, with the included wireless receiver, positioned up to 100 feet from the host computer. Each unit will accommodate up to 7 type T thermocouple sensors and multiple Thermes units may be connected to the same computer for more thermocouple inputs. A high accuracy electronic cold junction compensation circuit maintains typical system accuracy of ±0.2°C over an ambient temperature range of 15 to 35°C. Individual offsets may be added to each input in software to facilitate individual calibration of each channel. (see THERMES-USB WFI)

  • PLC's

    Datexel

    The EPL101 PLC is a circuit board OEM PLC. The EPL101 has 4 analog inputs, 7 digital inputs and 2 inputs for Encoders. It has 6 relay outputs, 5 that are rated for 5 Amps and 1 relay rated for 16 Amps. It also has an analog output 0-5 Volts. The outputs can be simple on off or P, PI,PID or PD control. The EPL101 accepts inputs from K, S, T, R, J or E type thermocouples, Pt100, Ni100 RTD'S. NTC10K thermistor inputs. The EPL101 also accepts inputs from sensors with 4-20mA, 0-20mA, 0-20mV or 0-1V signal. It also has 6 digital PNP inputs up to 1 Hz and 2 NPN inputs up to 2 K Hz.