  • Drop Weight Impact Testing Machine

    DWTT Series - Jinan Testing Equipment IE Corporation

    DWTT Drop Weight Impact Testing System is suitable for drop weight tear test of various kinds of ferrite, especially for the test of DWTT for pipeline steel as ASTM-E 436, API-RP 5L3, ASTM-E 208 and DIN EN 10274. DWTT has integrated mechanical, electrical, and automatic control technology, and achieved full automation of feeding, hammer lifting impact, and fracture specimen collection. The load frame has a four-column design, features in stable supporting structure, rigid, dual sliding rails. The Drop Weight Drop Weight Tester is equipped with positioning mechanism, anti-dumping mechanism, safety mechanism, hydraulic buffer devices and security guard net. The impact energy is determined by the lifting height and configuration of different net weights. DWTT Drop Weight Impact Testing System is the essential quality control equipment for pipeline manufacturers, steel mills, iron and steel enterprises, and is also widely used for research institutes.1. Buffer device is equipped to avoid the second impact and absorb the residual energy after breaking the specimen so as to prevent the weigher and anvil from destroying. The installation of safety mechanism, buffer device, and security guard net will effectively secure the testing machine and its operation to extend its life.2. Configuration of the specimen-feeding system, anti-second impact device, and specimen centering mechanism will guarantee a quick, accurate and reliable test.

  • ±6 kV ANSI/ESDA/JEDEC HBM Test System

    HBM-TS10-A - High Power Pulse Instruments GmbH

    *±6 kV Human-Body-Model (HBM) tester according ANSI/ESDA/JEDEC JS-001 standard with C = 100 pF, R = 1.5 kΩ discharge network*Wafer, package and system level HBM testing*True HBM: the classical discharge network of the HBM-S1-A according the standard ensures compliant waveforms for all load conditions*No trailing pulses*Integrated 10 kΩ charge removal resistor*Integrated DUT HBM current sensor for real time transient current monitoring with 1V/A output sensitivity into 50 Ω digital oscilloscope input*Integrated DUT HBM voltage sensor for real time transient voltage monitoring with 1/200V/V output sensitivity into 50 Ω digital oscilloscope input*Integrated overvoltage protection of the DUT voltage sensor, DUTcurrentsensor and DC test interface for efficient overload protection of the digital oscilloscope and SMU during high voltage HBM testing*Integrated DC test DUT switch with automatic switch control*Integrated 50 Ω precision hardware trigger output for high speed digital oscilloscopes*Fast HBM measurements, typically 0.5s per pulse including one-point DC measurement between pulses*Eficient sofware for system control and waveform data management (fully compatible with TLP measurement data)*The sofware can control automatic probers for fast measurements of complete wafers*Compact size 145 mm x 82.5 mm x 44 mm of the integrated HBM pulse generator probehead*System controller size 483 mm x 487 mm x 133 mm*High performance and high quality components*Optionally available hardware upgrades to all HPPI fully integrated HBM/HMM/TLP/VF-TLP test systems TLP-3010C, 4010C, 8010A, and 8010C

  • Three-Phase Transformer Winding Resistance Meters

    TWA Standard Series - IBEKO Power AB

    When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.

  • TDR and Bridge Cable Fault Locator

    ST620B - Shandong Senter Electronic Co., Ltd

    I.OverviewThis DMM/TDR cable fault locator is the latest generation cable tester, which is designed with the technology of ARM+FPGA large dot matrix color LCD display . It is used for the measuring of exact fault location such as the broken line, cross faults, earthing, poor insulation and poor contact of the lead covered cables as well as plastic cables. It is an effective tool to reduce troubleshooting time, improve work efficiency and reduce labor intensity of line maintenance staff. It also can be used in line projects acceptance and inspection of electrical cableII. Features1. Large color LCD Display (480 x 280 dot); humanized operation interface; six function keys and simple operation.2.Combine with pulse reflection testing (TDR) and Digital Multimeter(DMM), can test broken lines, crossing lines, poor insulation and other types of faults.3. Manual testing function is preserved.4.Full English Menu is easy to master and use.5.With megameter and ohmmeter, it enables to test insulation resistance and loop resistance.6.With USB Port, it is easy to upload testing data to computer(This function is optional)7 Rechargeable lithium battery, intelligent charging without duty.8.Small dimension, light weight and portable design.Specifications1)Pulse reflection testing(TDR)Max range: 8 km(16kms, and 32kms are optional) Dead Zone: 0 mTesting Accuracy: 1mPulse width: 40ns-10μs with automatic adjustment Automatic impedance balance adjustment Automatic and manual gain adjustment2) Digital Multimeter(DMM)DC voltage: -400V~ 400V, resolution can reach 0.001VAC voltage: 0V~290VCapacitance: 0nF~1000nFAccuracy: 0--10nF: ±2nF; 10nF--1000nF : ±2% +±2 nF Loop resistance: 0Ω~20kΩAccuracy: 0--100: ± 3% +± 4Ω 100- 500: ±3% ; 500-20 KΩ ±2%Insulation resistance between line: 0M Ω -30M M Ω.Accuracy:0--1.0M: ±0.1M Ω 1.0M - 30M: ±10% + 0.5 MΩ.The charging time of about 3.5 hoursFull - after 8 hours of continuous operating timeSize: 210mm * 166mm * 90mmWeight: 1KgAccessories:1) Carry case.2) Re-chargeable battery and charger/adapter.3) Test Line4) User Manual5) CD (Just for USB function)6) U-disk (Just for USB function)

  • Phasing Voltmeter/Sensor (2 in 1)

    STB Electrical Test Equipment, Inc

    STB unit replaces 3 separate units manufactured by competitors - line phasing, capacitance phasing and line to ground Versatile, lightweight and easy to useEach portable meter has a single rangeMeter usage: Voltage detection and phasing at capacitance test points or voltage detection and phasing on bare energized conductors (overhead & underground)Probes can be separated to be used as a voltage sensor or capacitance sensorFive position selector switch used to select voltage sensing on capacitance tap or direct line and phasing on capacitance tap, direct line or a battery test positionNo exposed conducting terminals or meter circuitryLocking cable connector provides positive contactScale is large enough to be easily read 8'-10' when mounted on a suitable hot stickLine to ground voltage readings are accurate within 3% at full scaleMaximum operating temperature range -20°F to 165°F (-30°C to 75°C)25' coiled cable includedAccessoriesMODELDESCRIPTION50118-G-10Hot Sticks (full set - 6)10104-P-02Shepherd's Hook10104-P-03Probe Tip30142-P-01Shot Gun Adapter50111-P-01Regular Bushing Adapter10275-P-01Universal AdapterModelsMODELDESCRIPTIONWeight50101-G-07Phasing Voltmeter 9-36kV16 lbs.50101-G-08Phasing Voltmeter 9-36kV with Hot Sticks (full set - 6)21 lbs.Request QuoteOperating Instructions9-36kV Phasing VoltmeterProduct Summary/OptionsProvides safe and convenient testing means for paralleling 3-phase high voltage circuitsConsists of two resistance elements connected in series with an indicating meter in the series connectionTwo ranges, 9kV and 36kV, with a range selector switch mounted on the back of the meter housingSwitch is clearly marked for the range of the voltmeterTypical use: Line-to-ground voltage measurements and phase for paralelling operationsScale markings on the voltmeter have a minimum of divisions and the figures are large enough to be easily read 8'-10' away when mounted on a suitable hot stickInput impedance: Approximately 72 megohmsMaximum operating temperature range -20°F to 165°F (-30°C to 75°C)Ready to attach on hot stick10' cable, a proof tester, battery and shepherd’s hook and probe tip includedOperating InstructionsRequest QuoteOperating InstructionsModelsMODELDESCRIPTION50100-G-010-2kV DC Voltmeter 30’ cable, magnetic track adapter50100-G-020-1500kV DC Voltage Meter50100-G-030-1500kV DC Voltage Meter with Hot Sticks50100-G-04DC Voltmeter 1500kV DC w/Extension Probe and Ground Lead50100-G-050-1500V DC with Hot Sticks and Lighted Dial50100-G-060-1500 DC Voltage Meter with Lighted DialDC Voltmeter​Product Summary/OptionsLightweight, easy to use, hand-held meterHard wired unit Scaled 0-1500vDC, in 100 volt incrementsProvides a 2/3 full scale deflection when applied across 1000vDCMaximum current flow through instrument at 1000vDC is 0.05 milliampersNo polarity, sensitivity issuesMay be used to determine whether the third rail of a transit system is energizedInput impedance of approximately 24 megohmMaximum operating temperature range -20°F to 165°F (-30° C to 75°C) Request QuoteAC VoltmeterProduct Summary/OptionsTwo-position toggle switchPortable instrument for quickly and easily measuring AC voltages Locking cable connector provides positive, electrical contactResistive voltmeter - medium range voltage measurements in the fieldTypical use - measure voltage between ground and the line or bus connector20' ground lead includedInput impedance - approximately 36 meghomsMaximum operating temperature rangeAccuracy of +/- 3% full scaleShare to TwitterShare to FacebookShare to PrintShare to EmailMore AddThis Share options