product
48-Channel High Performance Strain Gauge Measurement Instrument
EX1629
48-Channel High Performance Strain Gauge Measurement InstrumentSupports quarter-bridge (120, 350Ω or user defined), half-bridge or full-bridge24-bit ADCs, sampling rates up to 25 kSa/sBuilt in programmable differential excitation -8V to 8VBuilt in selectable bridge completionConfigure signal conditioning excitation and bridge completion on a per channel basisSimple, low-cost wiring using RJ-45 telecom connectorsSupports TEDS for easy transducer detection and setupRJ-45 input connector reduces setup cost and timeBuilt in self-calibration and shunt calibrationSupports voltage, ratiometric and linear measurements other than strain measurements.
-
product
NI-9250, 2-Channel, 102.4 kS/s/ch Simultaneous, ±5 V, C Series Sound and Vibration Input Module
783827-01
2-Channel, 102.4 kS/s/ch Simultaneous, ±5 V, C Series Sound and Vibration Input Module - The NI‑9250 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers and microphones. The NI‑9250 is also compatible with smart TEDS sensors. The NI‑9250 delivers a wide dynamic range and incorporates software-selectable AC/DC coupling and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-ali...show more -
product
PXIe-4464 , 204.8 kS/s, 119 dB, 6 Gains, AC/DC-Coupled, 4-Input PXI Sound and Vibration Module
783087-01
204.8 kS/s, 119 dB, 6 Gains, AC/DC-Coupled, 4-Input PXI Sound and Vibration Module—The PXI‑4464 delivers simultaneous sampling on all channels. In addition, the PXI‑4464 includes built-in antialiasing filters that automatically adjust to your sampling rate, six software-selectable input gains ranges, and TEDS smart sensor support for error-free setup. The IEPE excitation circuit can deliver current for high-power sensors and strong data integrity over long sensor cable runs.
-
product
Headphone Test Fixture
AEC206
The Larson Davis Model AEC206 Binaural Test Fixture is the tool for testing supra-aural, circumaural, supra-concha, intraconcha, and insert-type headphones. Preassembled with IEC 60318-4 (711) occluded-ear simulators and TEDS compatible preamplifiers that provide electronic calibration information, the Model AEC206 is user-friendly and easy to learn. Additionally, calibration is a simple process—a custom adapter is included for the Model CAL250 acoustic calibrator or similar device.
-
product
ICP Microphone System
378C10
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
product
NI-9234, 4-Channel, 51.2 kS/s/channel, ±5 V, C Series Sound and Vibration Input Module
779680-01
4-Channel, 51.2 kS/s/channel, ±5 V, C Series Sound and Vibration Input Module - The NI‑9234 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9234 is also compatible with smart TEDS sensors. The NI‑9234 delivers a wide dynamic range and incorporates software-selectable AC/DC coupling and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-i...show more -
product
PXIe-4464, 204.8 kS/s, 119 dB, 6 Gains, AC/DC-Coupled, 4-Input PXI Sound and Vibration Module
783087-02
204.8 kS/s, 119 dB, 6 Gains, AC/DC-Coupled, 4-Input PXI Sound and Vibration Module—The PXI‑4464 delivers simultaneous sampling on all channels. In addition, the PXI‑4464 includes built-in antialiasing filters that automatically adjust to your sampling rate, six software-selectable input gains ranges, and TEDS smart sensor support for error-free setup. The IEPE excitation circuit can deliver current for high-power sensors and strong data integrity over long sensor cable runs.
-
product
NI-9234, 4-Channel, 51.2 kS/s/channel, ±5 V, C Series Sound and Vibration Input Module
779680-03
4-Channel, 51.2 kS/s/channel, ±5 V, C Series Sound and Vibration Input Module - The NI‑9234 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9234 is also compatible with smart TEDS sensors. The NI‑9234 delivers a wide dynamic range and incorporates software-selectable AC/DC coupling and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-i...show more -
product
FD-11634, 8-Channel Sound and Vibration Input Device for FieldDAQ
786471-01
The FD-11634 can measure signals from integrated electronic piezoelectric (IEPE) and non-IEPE sensors such as accelerometers, tachometers, and proximity probes. The device also works with smart TEDS sensors, delivers a wide … dynamic range, and incorporates software-selectable AC/DC coupling and IEPE signal conditioning. The input channels simultaneously measure signals and have built-in anti-aliasing filters that adjust to your sample rate. This device is IP65/IP67-rated to be dust-tight and wa...show more -
product
Tri-Axial Accelerometers with Built-In Preamplifier/Charge Output Type
The tri-axis acceleration detector is an accelerometer that can output electric signals in proportion of vibration acceleration, which has been converted from mechanical vibrations, at the same time from XYZ three vibration directions. Various types of accelerometers are provided including built-in preamplifier type, charge output type, and TEDS compatible type.
-
product
PXIe-4497, 204.8 kS/s, 114 dB, 2 Gains, AC/DC-Coupled, 16-Analog Input PXI Sound and Vibration Module
781369-01
204.8 kS/s, 114 dB, 2 Gains, AC/DC-Coupled, 16-Analog Input PXI Sound and Vibration Module - The PXIe‑4497 is designed for high‑channel‑count sound and vibration applications. With 24-bit analog inputs and IEPE constant current signal conditioning, the PXIe‑4497 is ideal for making precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. The PXIe‑4497 delivers simultaneous sample on all channels. In addition, the module includes built-in...show more -
product
Portable Hand Held Load Cell Indicator
MODEL SSI
The SSI is a Plug & Play Smart TEDS IEEE 1451.4 compliant portable handheld Load Cell Indicator. Just plug in a TEDS compatible Load Cell or Torque Sensor and the SSI will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the SSI can be set up by simple front panel push buttons. The SSI can be scaled to a full 5 digit display from 0 to 99,999 counts to read directly in engineering units such as grams, ounces, pounds, inch pounds, etc. The SSI also has a...show more -
product
Microphone System
378B02
This model includes a 1/2" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
product
Load Cell Transmitter
MODEL SST-HV
The SST-HV is a Plug & Play Smart TEDS IEEE 1451.4 compliant Transmitter. Just plug in a TEDS compatible Load Cell or Torque Sensor and the SST-HV will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the SST-LV Transmitter is easily programmed using a PC with an RS232 port and Instrument Setup (IS) software, which provides a graphical user interface. The SST-HV may be powered from 95-240 Vac ±10%. The SST-HV has an Isolated transducer excitation output tha...show more -
product
Microphone Preamplifier
426A11
1/2-inch ICP preamplifier with gain and filter switches (for prepolarized microphones)ICP(R) low noise preamplifier with gain, filters, and TEDS
-
product
Load Cell Indicator
9840
The 9840 is suitable for use in calibration labs, field service, or anywhere high accuracy is important. Features include a bipolar 6-digit 2-line display, remote sense, low noise, 22-bit resolution, USB port with RS232 communication, mV/V calibration and the ability to store up to 25 different sensors. 6-point linearization, unit conversion, front-panel tare. Self calibration via TEDS Plug & Play ready IEEE1451.4 compliance.
-
product
PXIe-4492, 204.8 kS/s, 113 dB, 2 Gains, 0.5 Hz AC/DC-Coupled, 8-Input PXI Sound and Vibration Module
781490-01
204.8 kS/s, 113 dB, 2 Gains, 0.5 Hz AC/DC-Coupled, 8-Input PXI Sound and Vibration Module - The PXIe‑4492 is designed for sound and vibration applications. With 24-bit analog inputs and IEPE constant current signal conditioning, the module is ideal for making precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. The PXIe‑4492 delivers simultaneous sample on all channels. In addition, it includes built-in antialiasing filters that auto...show more -
product
NI-9230, 3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
784396-01
3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9230 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9230 is also compatible with smart TEDS sensors. The NI‑9230 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in ant...show more -
product
Digital Panel Mount Load Cell Meter
MODEL DPM-3
The DPM-3 is a smart Plug & Play TEDS IEEE 1451.4 compliant Digital Panel Mount Load Cell meter. Just plug in a TEDS compatible Load Cell or Torque Sensor and the DPM-3 will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the DPM-3 can be set up by simple front panel push buttons. The DPM-3 can be scaled to a full 5 digit display from 0 to 99,999 counts to read directly in engineering units such as grams, ounces, pounds, etc. The DPM-3 samples 60 reading...show more -
product
Sensor Database Implementing Imc Plug & Measure Technology
imc SENSORS
imc SENSORS is a ready-to-go, universal database application for administering and editing sensor information. Along with values for smart sensors defined in IEEE P 1451.4 (TEDS), selections of additional sensor properties can be freely entered. These can be set, edited and viewed in freely configurable tabular views, e.g., the sensor's technical data information, as well as its calibration values.
-
product
NI-9230, 3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
783824-01
3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9230 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9230 is also compatible with smart TEDS sensors. The NI‑9230 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in ant...show more -
product
Structural Test ICP® Accelerometers
Conventional structural test data systems use few to several hundred sensors. Cables bundles can be complex and confusing resulting in setup errors. Sensors with TEDS (Transducer Electronic Data Sheet) allow for an internal sensor digital chip to store sensor information. This information contains descriptive identifiers that when connected to a TEDS compatible signal conditioner or data system, reads the descriptive information and automatically aligns the data system. Human error is minimi...show more -
product
Microphone Preamplifier
426B31
Performance:Nominal Microphone Diameter:1/4" Frequency Response:3.98 to 126000 Hz3.98 to 126000 10.0 to 126000 Hz10.0 to 126000 HzElectrical Noise (A-weight)3.8 TEDS CompliantYes
-
product
FD-11601, 8-Channel, ±10 V Powered-Sensor Voltage Input Device for FieldDAQ
786374-01
The FD-11601 measures up to eight channels with a voltage input range of ±10 V. Each input channel supports TEDS and provides 24 V DC to power external-powered sensors without additional power supplies. The FD-11601 features 24-bit resolution, simultaneous sample rates up to 100 kS/s/ch, and channel-to-channel isolation. It is IP65/IP67 rated to be dust-tight and water-submersible, operates in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 g vibration. The FD-11601 incorporates...show more -
product
ICP Microphone System
378A14
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
product
NI-9232, 3-Channel, 102.4 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
784397-01
3-Channel, 102.4 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9232 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9232 is also compatible with smart TEDS sensors. The NI‑9232 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in an...show more -
product
Multi-purpose Signal Conditioners
The 482C series comprises 4-channel benchtop signal conditioners, while the 483C series offers 8-channel rack-mounted units. Utilizing identical signal conditioning electronics across equivalent 4 and 8-channel models ensures consistent performance. Both signal conditioner series offer standalone units with essential functionalities, as well as units equipped with advanced features like a front panel keypad and display or an Ethernet port for computer control. Additional features encompass gain adjustment, filtering options, LED fault indicators, and TEDS capability.
-
product
NI-9232, 3-Channel, 102.4 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
782000-01
3-Channel, 102.4 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9232 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9232 is also compatible with smart TEDS sensors. The NI‑9232 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in an...show more -
product
sbRIO-9234 , Non-Enclosed, 4-Channel, 51.2 kS/s/channel, ±5 V, C Series Sound and Vibration Input Module
782718-01
Non-Enclosed, 4-Channel, 51.2 kS/s/channel, ±5 V, C Series Sound and Vibration Input Module - The sbRIO‑9234 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The sbRIO‑9234 is also compatible with smart TEDS sensors. The sbRIO‑9234 delivers a wide dynamic range and incorporates software-selectable AC/DC coupling and IEPE signal conditioning. The input channels simultaneously measure signals. Each c...show more -
product
PXIe-4480, 1.25 MS/s, 3.4 Hz AC/DC-Coupled, 6-Input PXI Sound and Vibration Module
784277-01
1.25 MS/s, 3.4 Hz AC/DC-Coupled, 6-Input PXI Sound and Vibration Module—The PXIe‑4480 is designed for high-bandwidth audio, acoustic, and vibration measurements. It provides six channels of dynamic signal acquisition, and you can use one of four gain settings to configure your input range. The PXIe‑4480 also includes software-configurable AC/DC coupling, charge measurement, voltage excitation, IEPE excitation, and TEDS support, making it ideal for measuring acoustic transducers, pressure sensors...show more