TEDS
Transducer Electronic Data Sheets
-
product
NI-9230, 3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
784396-01
3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9230 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9230 is also compatible with smart TEDS sensors. The NI‑9230 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
product
FD-11634, 8-Channel Sound and Vibration Input Device for FieldDAQ
786471-01
The FD-11634 can measure signals from integrated electronic piezoelectric (IEPE) and non-IEPE sensors such as accelerometers, tachometers, and proximity probes. The device also works with smart TEDS sensors, delivers a wide … dynamic range, and incorporates software-selectable AC/DC coupling and IEPE signal conditioning. The input channels simultaneously measure signals and have built-in anti-aliasing filters that adjust to your sample rate. This device is IP65/IP67-rated to be dust-tight and water-submersible and can sustain 100 g shock and 10 g RMS vibration in -40°C to 85°C environments. You program the FD-11634 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. When used with NI software, this device can provide processing functionality for condition monitoring such as frequency analysis and order tracking.
-
product
Portable Hand Held Load Cell Indicator
MODEL SSI
The SSI is a Plug & Play Smart TEDS IEEE 1451.4 compliant portable handheld Load Cell Indicator. Just plug in a TEDS compatible Load Cell or Torque Sensor and the SSI will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the SSI can be set up by simple front panel push buttons. The SSI can be scaled to a full 5 digit display from 0 to 99,999 counts to read directly in engineering units such as grams, ounces, pounds, inch pounds, etc. The SSI also has a Units key for automatic conversion of readings for load, torque and pressure. The SSI has an ultra-fast signal-sampling rate of 15,360 samples/second for true peak and/or valley testing capability. Auto-tare allows the meter to be set to zero for any input signal level. The SSI also features a USB port for data logging to a PC. You can also log data to the SSI’s internal memory storing up to 16,000 time and date stamped readings. The SSI also features 2 built-in solid-state alarm relays with LED and audible indicators. The SSI will operate up to 65 hours on a single charge or use the included battery charger for applications where the SSI is mounted permanently.
-
product
Sensor Database Implementing Imc Plug & Measure Technology
imc SENSORS
imc SENSORS is a ready-to-go, universal database application for administering and editing sensor information. Along with values for smart sensors defined in IEEE P 1451.4 (TEDS), selections of additional sensor properties can be freely entered. These can be set, edited and viewed in freely configurable tabular views, e.g., the sensor's technical data information, as well as its calibration values.
-
product
ICP Microphone System
378A14
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
product
NI-9232, 3-Channel, 102.4 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
782000-02
3-Channel, 102.4 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9232 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9232 is also compatible with smart TEDS sensors. The NI‑9232 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
product
NI-9230, 3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
783824-01
3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9230 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9230 is also compatible with smart TEDS sensors. The NI‑9230 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
product
NI-9230, 3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
783824-02
3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9230 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9230 is also compatible with smart TEDS sensors. The NI‑9230 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
product
NI-9234, 4-Channel, 51.2 kS/s/channel, ±5 V, C Series Sound and Vibration Input Module
779680-03
4-Channel, 51.2 kS/s/channel, ±5 V, C Series Sound and Vibration Input Module - The NI‑9234 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9234 is also compatible with smart TEDS sensors. The NI‑9234 delivers a wide dynamic range and incorporates software-selectable AC/DC coupling and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
product
Accelerometer
BC 110
*General purpose accelerometers with integrated electronics;*Sensitivity: 100 mV/g;*Frequency range: 0,5…10000 Hz;*TEDS sampling technology.
-
product
ICP Microphone System
378C01
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration. Click the following for individual component information.
-
product
ICP Microphone System
378C10
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
product
Precision Condenser Microphone
378A12
1/4-inch pressure prepolarized 377A12 microphone, with 1/4-inch preamplifier 426B03 and TEDS v0.9
-
product
NI-9231, 8-Channel, 51.2 kS/s/channel, -5 V to 5 V, C Series Sound and Vibration Input Module
783610-01
8-Channel, 51.2 kS/s/channel, -5 V to 5 V, C Series Sound and Vibration Input Module - The NI-9231 is a high-density sound and vibration module that can measure signals from integrated electronic piezoelectric (IEPE) and non-IEPE sensors such as accelerometers, tachometers, and proximity probes. It can perform the high dynamic range measurements necessary for modern measurement microphones and accelerometers and features simultaneous sampling. The NI-9231 incorporates both a TEDS input path and 2 mA of IEPE signal excitation source that can be turned on and off, removing the need for external sensor power and reducing the complexity of the data acquisition system.
-
product
PXIe-4499, 204.8 kS/s, 114 dB, 4 Gains, AC/DC-Coupled, 16-Input PXI Sound and Vibration Module
781370-01
204.8 kS/s, 114 dB, 4 Gains, AC/DC-Coupled, 16-Input PXI Sound and Vibration Module - The PXIe‑4499 is designed for high‑channel‑count sound and vibration applications. With 24-bit analog inputs and IEPE constant current signal conditioning, the PXIe‑4499 is ideal for making precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. The PXIe‑4499 delivers simultaneous sample on all channels. In addition, the PXIe‑4499 includes built-in antialiasing filters that automatically adjust to your sample rate, software-selectable input gains, and TEDS smart sensor support for error-free setup. Common applications include noise, vibration, and harshness (NVH) analysis; large microphone arrays; and dynamic structural test.
-
product
Tri-Axial Accelerometers with Built-In Preamplifier/Charge Output Type
The tri-axis acceleration detector is an accelerometer that can output electric signals in proportion of vibration acceleration, which has been converted from mechanical vibrations, at the same time from XYZ three vibration directions. Various types of accelerometers are provided including built-in preamplifier type, charge output type, and TEDS compatible type.