- Pickering Interfaces Inc.
product
PXI Analog Output/Current Loop Simulator Module - 12 Channel
41-765-002
The 41/43-765-002 is a 12-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
product
Telephone & Exchange Tester
ETT 10
Maintenance statistics of telephone networkshave shown that for most of the failures, theexchange - line - subscriber (EXCH-LINE-TEL) sections are responsible. Accordingly, the first step of the troubleshooting procedure is to locate the breakdown spot, i.e. to find out whether thefailure source is within the exchange, the subscriber site or in the line (local loop). Thisproblem can be easily solved by theTelephone & Exchange Tester ETT 10, in most cases without requiring the technician to visit the subscriber or the junction boxes along the line.
-
product
Carrier Convergence Processors
Macom Technology Solutions Holdings Inc.
Macom offers a line of infrastructure voice processors, in concert with the carrier-grade Media Stream Processing software, that delivers a complete, integrated VoIP media, data and fax, signaling and control processing solution. Combined with powerful DSP cores with flexible packet processing engine and a rich set of interfaces, the processors support 256 to 640 channels of packet-TDM and packet-packet operation across the entire range of IP modulations, for VoIP and VoATM applications. A large...show more -
product
Loop Testing
Megger loop testers offer both traditional measuring techniques and state of the art “non-RCD Tripping” technology. Use these products to determine the prospective earth fault current, which is the maximum current able to flow in a phase-earth fault in an installation, and also to indicate the prospective short circuit current which is the maximum current able to flow in the event of a phase-neutral fault.
-
product
Radiating Loops
The magnetic, handheld coil was designed to generate defined mag-netic fieldstrength in the frequency range from DC up to 5 (7) MHz. The main application is immunity testing against magnetic fields.
-
product
Loop Calibrator
Model KM CAL-904-MK1
Kusam Electrical Industries Limited
• 4-20mA (1kΩ Load, 24V Loop Output).• 0-20mA and 0-24mA output ranges.• 0.025% Basic Accuracy.• Auto Ramp and Step functions.• 0-100% output with percentage step option.• 0-24V DC voltage source.• Open loop and overload buzzer alarm.• Low battery indication.• Simple Operation Interface• Warning beeper when output is open• Pollution Degree 2.• Ambient temperature 0~40℃.• Power Consumption 150mA at 24V 1kΩ load
-
product
Loop Antenna
ZHX7-0.009-200-1486
Loop Antenna, Frequency 0.009~200MHz, Linear Polarization, N-Female
-
product
Loop Antennas
A loop antenna is a radio antenna consisting of a loop or coil of wire, tubing, or other electrical conductor, that for transmitting is usually fed by a balanced power source or for receiving feeds a balanced load.
-
product
Single Loop Controller
1460
he 1460 has been designed to provide immediate visibility to the operator. At a glance, the programmable displays will show you the measured variable, the set point and the parameter being edited, the number of cycles or time remaining, the recipe name and number and also whether the cycle is in a ramp or soak mode
-
product
Single Loop Controller
1462
The N4400 is a sophisticated, single loop controller which provides extensive profiling programming options for complex processes. The controller can create a profile with up to 121 segments, store up to 8 programs and configure and store extra programs on a PC.
-
product
Open Loop Current Sensor
C03 30A
The C03 offers efficient and precise sensor solutions for direct, alternating and pulsed currents in industrial, commercial and communication systems. It consists of three main components: an accurate, linear Hall sensor with low temperature drift, a flux collector and a transformer. It is characterized by a very low resistance and thus lowers power loss and temperature drift - for optimal performance.
-
product
Antenna, Loop Sensor
EM-6873 | 20 Hz – 100 KHz
The EM-6873 Loop Sensor Antenna uses passive circuits to transform magnetic field components between 20 Hz – 100 kHz to an equivalent open circuit two-terminal voltage on the receiving instrument. Use of the conversion Factor Chart, supplied with each antenna, will yield the strength of the magnetic induction field referenced to a uniform field. The loop is electrostatically shielded and therefore is sensitive only to the magnetic component (B-field) of the electromagnetic fields.
-
product
Antenna, Loop
EM-6871 | 30 Hz – 1 MHz
The EM-6871 Antenna can be used with any 50 ohm /Receiver/Field Strength Meter to obtain magnetic field measurements from 30 Hz to 1 MHz.
-
product
Ground Loop Transformer - VT11
Humdinger
A wideband CCTV video-isolating transformer (ground loop transformer) used for the reduction of longitudinal mains induced hum. For high-resolution video signals and 'down the cable' telemetry it is essential that all components in the signal path are of sufficient bandwidth to pass the full frequency range of both signals with minimal distortion.
-
product
MULTI-STANDARD LOCAL LOOP SIMULATOR
458-LM-A8-30
Accurately simulates attenuation and impedanceFull bidirectional operation at all specified frequencies26 AWG PIC as specified in ANSI T1.417
-
product
Single Loop Controller
1400+
The 1400+ controller is an evolved product from the West N4100. The product benefits from having more versatile features and user-friendly functionalities such as remote setpoint inputs, digital inputs, plug-in output modules, a customisable operator/HMI menu, jumperless and auto-hardware configuration, and 24VDC transmitter power supply.
-
product
Open Loop Current Sensor
K03
The K03 series is a current sensor based on the Hall effect. It enables the electronic measurement of direct, alternating or pulsed currents as well as their combinations with galvanic separation between primary (high current) and secondary circuits.
-
product
Short Circuit Loop Impedance Meter
AMZC-306
Voltage measurement up to 750V and up to 250V with resolution 0,1V ; Measurements using Uni-Schuko adapter or test wires 1,2; 5; 10 and 20m ; Loop impedance measurement with resolution 0,01Ω and much more
-
product
Open And Closed Loop Inverters
VFD
Inverter products support the energy-saving operation of equipment and machinery with fine speed control.
-
product
4-20mA Current Loop D/A Converters
ADI integrated solutions combine both the D/A converter and driver in one chip to provide the required output directly from the digital domain. Analog Devices’ portfolio of leading industrial D/A converters and drivers provides a range of programmable output ranges from standard 4 mA to 20 mA for current loop communication to ±10 V for actuator control. ADI industrial converters offer considerable control functionality and advanced on-chip diagnostics to maximize system uptime, as well as eliminate the need for costly calibration routines needed by some traditional discrete architectures.
-
product
Friction Flow Loop System
Friction Flow Loop System is used for testing the effects of friction reducers by circulating at high rates through different pipe diameters. Friction Loop designs vary based on the application required.
-
product
Hysteresis Loop Tracer
MESA
The MESA is the only hysteresis loop tracer on the market that can make measurements in the frequency range of 10 Hz and below. Competing units operate with more-easily generated 60 Hz drive fields, and can have errors of as much as 30% in coercivity (Hc) measurements.
-
product
Antenna, Loop
EM-6874 | 20 Hz – 30 MHz
The EM-6874 Loop antenna is nominally used 20 Hz to 30 MHz and is designed for uncalibrated substitution measurements of shielding effectiveness as described by MILSTD-285, IEEE STD 299, and NSA-65-6.
-
product
Phase Locked Loop with Integrated VCO
PLL with integrated VCOs provide local oscillator sources and clock sources for communications (COMMS) , test and measurement (ETM) and aerospace/defense (ADEF) applications. ADI's PLLs with integrated VCO portfolio includes both narrowband and wideband parts, supporting frequencies up to 13.6GHz. Our PLLs with integrated VCO, as well as our full PLL portfolio including integer-N and fractional-N PLLs, feature best-in-class performance for phase noise, jitter, and spurious, and also feature high levels of integration in small form factor packages.
-
product
Modular Breakout System for Hardware-In-Loop Simulation
Designed in partnership with OPAL-RT Technologies, this Modular Breakout System combines a BoB feature set with the added flexibility of an FIU. By mating the FIU chassis directly to the BoB using our plug-in modules, cabling is minimized, creating a more compact reliable design and improving signal integrity.
-
product
Temperature Loop Control Setup
ULP-27
Unitech Scales And Measurements Pvt. Ltd
Unitech’s Temperature Control Loop Setup is basically a PC based PID controller setup used for closed loop and open loop analysis of temperature process system. The setup comprises of RTD temperature Sensor. The water flows through the Rotameter and Process tank to which a heating coil is fitted. The heater is controlled by a Thirstier drive. The Thirstier drive is connected to PID controller. The manual control valve can control the water flow. The system is mounted on a tabletop model with all necessary Piping. Water at approx. 100 LPH has to be supplied to a system externally. The electronic panel comprises of ADC/DAC card with RS-232 interfaces.
-
product
- RS-232 to Current Loop Converter
Model 65A
FEATURES: Active/Passive Loops; 20 or 60 mA. Operation; DC To 19.2 KBPS; Half/Full Duplex; Optically Isolated; DTE/DCE Selectable. The Model 65A is a small, versatile, RS-232 to Current Loop Converters for use with teletypes or computers providing local terminal input via a 20mA. (or 60 ma.) current loop. The Model 65 includes a wall mounted transformer and internal power supply circuitry.
-
product
Antenna, Active Loop
EM-6869 | 9 KHz – 50 MHz
The Electro-Metrics EM-6869 Active Loop Antenna is used with any receiver or spectrum analyzer with 50 ohm input and covers the frequency range of 9 kHz to 50 MHz.
-
product
Panel-mounted Power Amplifier(Hardware In The Loop Simulation)
PA30Bi
PA30Bi is the panel-mounted type real time simulation amplifier with three-phase current and four-phase voltage.
-
product
Current Loop Data Loggers
This data logger can measure and store 4~20mA DC current readings automatically. The professional applications can be provided by the PC software DGraphTM. Logger status, alarm indication and low battery indication are via flashing red/green LED and yellow LED. The button on housing can be used to start logging, or confirm and clear LED alarm when LED alarm is hold status.
-
product
3-Dimensional Loop Antenna Van Veen
Loop Antenna System ( LAS )3-dimensional large loop antennadiam. 2 macc. EN 55015 / CISPR 15