Filter Results By:

Products

Applications

Manufacturers

Stepping Motor

A device that translates electrical pulses into precise mechanical movement. The output shaft may deliver rotary or linear motion. (www.seanet.com)

See Also: Electric Motor, Servomotor


Showing results: 1 - 8 of 8 items found.

  • Motor Test for Stepping Motors

    M.E.A. Testing Systems Ltd.

    *Stable measurement: Since it uses Prony braking, this model provides stable measurement unaffected by moments of inertia and no coupling loss. In addition, the resulting measurements allow data correlation via the traditional double-balance method.*Precision measurement method: This model’s judgment of synchronization loss achieves high stability using algorithms developed by Sugawara Laboratories. Measurement mode can be chosen based on step angle. For pull-in torque, startup can be measured consistently from the holding state. Allows measurement at 1-Hz resolution.*Broad measurement range: This model offers a range of seven available measurement heads, from 0.5 N to 50 N, allowing use for high-precision measurements. Through selection and use of pulleys, this model can also be used to measure small motors of 0.5 mN·m or less or 500 mN·m motors. Pulley diameters and other settings are easily configured using a personal computer running Windows®. Note: Any of the seven available heads may be attached to a single measurement component.*High-visibility measurement data: Motor characteristics are easily ascertained on automatically plotted performance graphs. Measurement data can be overlaid up to four times. In addition, the cursor can be used to read accurate values from measurement points. Hard copies of data displayed on-screen can be printed from a personal computer.*Can be controlled using standard personal computers: Allows control of measurement operations and display and storage of data from a standard personal computer running Windows®. Data is stored in CSV-format files for compatibility with other software applications.

  • Motor Starting Auto-Transformers

    Hilkar

    Motor Starting Auto-Transformers reduce the inrush current by stepping down the applied voltage during the start-up operation of induction and synchronous motors.

  • Shield

    Arduino Motor Shield Rev3 - Arduino llc

    The Arduino Motor Shield is based on the L298 (datasheet), which is a dual full-bridge driver designed to drive inductive loads such as relays, solenoids, DC and stepping motors. It lets you drive two DC motors with your Arduino board, controlling the speed and direction of each one independently. You can also measure the motor current absorption of each motor, among other features. The shield is TinkerKit compatible, which means you can quickly create projects by plugging TinkerKit modules to the board.

  • Single-phase Electricity Meters

    Applied Meters, a.s.

    Single-phase static electricity meters AMS B1x-SAx are determined for direct and indirect measurement of active energy displaying value on mechanical register with stepping motor. In the case of CT (current transformer) operated meters (x/5A) it is necessary value of register to multiply by the current transformer ratio.

  • Micropositioner

    XYZ 500 MIMT - Quarter Research and Development

    Submicron manipulator and translation stage. The XYZ-500-MIMT Micropositioner is intended for precise probing and instrumentation for industrial, medical, biological, semiconductor, and general scientific applications. It provides 3-axis motion with .500" movement on each axis. Motion is controlled by three precision stepping motors attached to precision gear heads 64:1 (standard), that drive a 100 threads per inch screw (standard).

  • Three-phase Electricity Meters

    Applied Meters, a.s.

    Three-phase static electricity meters AMT B1x-S(D)xxTE are determined for single-rate or double-rate active energy measurement in direct and indirect connection, displaying results on mechanical register with stepping motor. In the case of CT (current transformer) operated meters (x/5A) it is necessary value of register to multiply by the current transformer ratio.

  • Spectrographs & Monochromators

    ZOLIX

    Manual micrometer adjustable slits for precision control of incoming light. Motorized Slit and fixed slit is optional. More than 100 gratings for the best spectral range, throughput and dispersion to meet your applicationDSP controlled stepping motor scanning system provides superior precision and repeatability of wavelength positioningOptional internal shutter or six-position filter wheel for experiments requiring background removal or signal attenuationInstallation and set-up through USB 2.0 computer interfaces Stand-alone Omni Series monochromator control software for basic scanning and calibration. Also includes utilities for grating updates and communications Active X control support Visual Basic, C++ and Delphi drivers allow users to design their own acquisition programsZolixScan data acquisition software provides a simple user interface for easy data acquisition and experimental set-up

  • Omni-λSeries Imaging Spectrograph

    Omni-λi - ZOLIX

    Zolix Imaging Spectrometer includes different focal length 320mm, 500mm, 750mm; ◆Manual micrometer adjustable slits for precision control of incoming light. Motorized Slit and fixed slit is optional. • More than 100 gratings for the best spectral range, throughput and dispersion to meet your application◆DSP controlled stepping motor scanning system provides superior precision and repeatability of wavelength positioning◆Optional internal shutter or six-position filter wheel for experiments requiring background removal or signal attenuation◆Installation and set-up through USB 2.0 computer interfaces • Stand-alone Omni Series monochromator control software for basic scanning and calibration. Also includes utilities for grating updates and communications◆ Active X control support Visual Basic, C++ and Delphi drivers allow users to design their own acquisition programs◆ZolixScan data acquisition software provides a simple user interface for easy data acquisition and experimental set-up

Get Help