Showing results: 31 - 45 of 69 items found.
-
Crystal instruments
EDM Modal MIMO FRF Testing includes a dedicated test setup and operation process flow using multiple simultaneous shakers to acquire FRF signals. Using a large channel count data acquisition system (i.e., Spider- 80X or Spider-80Xi), this shaker excitation method provides much higher efficiency and accuracy for the FRF measurements while minimizing local stresses on the test article.
-
Data Physics Corp.
The 900 Series vibration controllers incorporate Data Physics’ renowned shaker control algorithms with a modern software interface and new hardware. The 900 Series controller can quickly be set up to control any shaker – while the 900 series platform offers advanced features such as auto-aggregation of data from all test stands, custom Word-based reporting, unlimited expandability, concurrent data recording and signal analysis, intrinsic safety, and more.
-
SV 111 -
SVANTEK Sp. z o.o.
SV 111 vibration calibrator is the State of the Art instrument designed for human vibration measurements according to ISO 8041. The design of the calibrator is based on the triaxial reference accelerometer and microprocessor controlled shaker. These both features assure excellent stability of the calibration levels and their frequency independently from mass of the testing object, like also indicate improper test object fixing by monitoring of shaker vibration in all three axis simultaneously.
-
m-series -
IMV Corporation
DC powered cooling fan is built-into the shaker. Natural air cooling is also used when the cooling fan is stopped for silent operation. (with a reduction in performance)
-
ETV-SERIES -
Envisys Technologies
Environmental Chamber with Vibration Shaker Interface provision consists of Environmental Test Chamber, Vibration Shaker Interface Provision, HMI/PC PLC based Control System etc., This chamber is designed with unique features to meet the control parameters like Temperature, Humidity (optional) and 3 Axis Vibration Controls which are specified in the specification.
-
VibraTest Series -
L. A. B. Equipment, Inc.
Purpose - lost cost mechanical shaker for testing products and components to in-service vibration conditions between 8 to 60Hz. Maximum acceleration to 3.2G is standard, up to 10G optionally.
-
Arden Photonics LTD
Arden’s MPX Modal Explorer makes measurement of Encircled Flux easy, and accurate, and it complies with international standards. But if you are measuring laser-based transmission light sources for multimode systems you may need to use a test jumper assembly and fiber shaker in order to avoid “speckle”. Industry standards (for example IEEE 802.3aq and FOTP– 203) call for the use of a mechanical fiber shaker.
-
Labtone Test Equipment Co., LTD
Environmental test system, Electro-dynamic Shaker, Shock Test Systems, Drop Tester, Bump Test Systems, Combined Environmental Test Systems
-
Vibration Controllers -
Vibration Research Corporation
Set up and safely control vibration shaker tests using any VR hardware and generate customized reports. Configure the VibrationVIEW control software for as many or as few test modules as you’d like (à la carte). Pick your control hardware based on specified needs.
-
ATA Engineering, Inc.
We pioneered the use of random excitation for modal testing and extended the method to include multishaker random testing and polyreference data processing. We have unsurpassed experience in modal testing of aerospace and industrial systems, including large scale testing for aerospace systems with over 400 accelerometers and eight shakers.
-
M+P International
Random control is one of the two basic and most common excitation modes for Environmental Shaker testing. Random performs real-time closed-loop control of PSD profiles. The m+p VibControl vibration control system allows the user to designate all input channels as control, watchdog and/or measurement channels.
-
Classical Shock -
ZETLAB Company
Software Classical shock is used for testing specimen resistance to shock impact. As the Software Classical shock is activated, at the output of shaker control system ZET 017-U there is formed a signal with pre-set parameters. Types of signals generated:
-
M+P International
Sine control is one of the two basic and most common excitation modes for Environmental Shaker testing. This control mode performs real-time closed-loop control of swept sine vibration. The m+p VibControl vibration control system allows the user to designate all input channels as control, watchdog and/or measurement channels.
-
MB Dynamics Inc.
At MB Dynamics, we take great pride in our ability to serve clients in a wide range of industries with world-class vibration testing and vibration measurement and analysis products. MB’s family of products has grown over the years, beginning with electrodynamic shakers and developing into an extensive inventory which includes a variety of application-specific solutions.
-
AT-2050 -
Agate Technology
AT-2050 was designed as a next generation portable vibration calibrator and shaker table. It is capable of providing precision calibration of a wide variety of vibration and motion sensors without the external power or meter requirements that are commonly found on other models.