Filter Results By:

Products

Applications

Manufacturers

Scattering

a propagating wave or moving particle's linear trajectory, interrupted by non-uniformity in the medium they move through.


Showing results: 46 - 60 of 74 items found.

  • Brightness Color meter

    SKZ102B - SKZ Industrial Co., Ltd

    Brightness Meter is widely applied in paper and cardboard, pulp, cotton and fabric, plastic, ceramic and porcelain enamel, amylum, construction material, chemical industry, salt making and other testing department that need to test whiteness, yellowness, color and chromatism, as well as transparency, opacity, light scattering coefficient and light absorption coefficient of paper.

  • Physical Contact Connectors

    Amphenol Fiber Systems International

    Physical Contact (PC) connections are characterized by the physical mating of two optical fibers. Precision ceramic ferrules are typically utilized for PC connections. A PC connection is accomplished by terminating the optical fiber into a precision ceramic ferrule. Epoxy is used to affix the fiber into the ferrule. The tip of the ceramic ferrule is polished in a precise manner to ensure that light enters and exits at a known trajectory with little scattering or optical loss. Polishing the terminated ceramic ferrule is a critical process in Physical Contact fiber optic connectors.

  • Air Particulate Counter

    CHY002 - Rinch Industrial Co.,Limited

    Using import semiconductor laser tube and import semiconductor photosensitive tube, assure sensitivity and response speed.Using import micropump,assure sampling volume steady,reduce noise.The key component-light scattering sensor obviously eliminate intracorporal stray light, improve SNR, test result more precise and reliable.The light scattering sensor got Chinese patent.Confidence measurement of this instrument,According to GB/T6167-2007 Standard,realize auto estimate clean class, creatively to auto estimate ≤9 location points clean class.1000 records stored, free to check previous data.User can optional PC data analysis software, realize data management.User can choose humidity sensor (optional accessories).Sampling volume display as digit, more intuitive and precise.“Measurement Number”function,realize multipoint management.Lithium battery,more safety,continuous working 6 hours.

  • Water Treatment Plant Analyzer

    HORIBA, Ltd.

    Aqualog® is the only instrument to simultaneously measure both absorbance spectra and fluorescence Excitation-Emission Matrices. EEMs are acquired up to a 100 times faster than with other instruments. Dedicated software automates traceable Quinine Sulfate Unit calibration and correction of inner-filter effects and Rayleigh and Raman scattering lines, enabling rapid export to modeling algorithms like PARAFAC.

  • Water Treatment Plant Analyzer

    Aqualog - HORIBA, Ltd.

    Aqualog® is the only instrument to simultaneously measure both absorbance spectra and fluorescence Excitation-Emission Matrices. EEMs are acquired up to a 100 times faster than with other instruments. Dedicated software automates traceable Quinine Sulfate Unit calibration and correction of inner-filter effects and Rayleigh and Raman scattering lines, enabling rapid export to modeling algorithms like PARAFAC.

  • Particle Sensor

    HPM Series - Honeywell Sensing & Control

    The Honeywell HPM Series Particle Sensor is a laser-basedsensor which uses the light scattering method to detectand count particles in the concentration range of 0 g/m3to 1,000 g/m3 in a given environment. A laser light sourceilluminates a particle as it is pulled through the detectionchamber. As particles pass through the laser beam, the lightsource becomes obscured and is recorded on the photo orlight detector. The light is then analyzed and converted toan electrical signal providing particulate size and quantity tocalculate concentrations in real time. The Honeywell particlesensor provides information on the particle concentration forgiven particle concentration range.

  • Laser Turbidity Meter

    HU-200TB-EH - HORIBA, Ltd.

    HU-200TB-EH is a laser-type turbidity meter that can measure turbidity of membrane filtered water, etc. with a resolution of 0.0001 degrees. A high-sensitivity turbidty meter with a minimum resolution of 0.0001 degrees at a measurement range of 0.0000 to 2.0000 degrees, which uses a long-lasting semiconductor laser as the light source and employs a transmission 90-degree scattering light method.This is best suited for sensitive measurement of turbidity on surface water.

  • X-Ray Photoelectron Spectrometer

    AXIS Supra - Kratos Analytical Ltd

    AXIS SupraTM is an X-ray photoelectron spectrometer (XPS) with unrivalled automation and ease of use for materials surface characterisation. The patented AXIS technology ensures high electron collection efficiency in spectroscopy mode and low aberrations at high magnifications in parallel imaging mode. XPS spectroscopy and imaging results can be complemented by additional surface analysis techniques such as: ultraviolet photoemission spectroscopy (UPS); Schottky field emission scanning Auger microscopy (SAM) and secondary electron microscopy (SEM) and ion scattering spectroscopy (ISS). The AXIS Supra replaces the AXIS Ultra DLD as Kratos' flagship x-ray photoelectron spectrometer.

  • Smaet LDV III

    KANOMAX USA, Inc.

    A Laser Doppler Velocimeter (LDV) measures fluid velocity by utilizing coherence of laser light. It detects the Doppler shift frequency of the scattering light of particles in the fluid and calculates the velocity of the particles (fluid). With a LDV system, non-intrusive measurements without disturbing the measuring object, liquid or gas flow, are achieved. No calibration is necessary and reverse flow measurements at a high resolution is also possible. The LDV system provides the absolute value of the flow velocity with accuracy.

  • UV Man Spectrometer

    HORIBA, Ltd.

    UV Raman (with laser wavelengths below 400nm) can be used to probe specific sample properties, and benefit from experiment properties different from typical visible Raman measurements – for example, greatly increased Raman scattering efficiency, modified laser penetration within the sample, and resonance coupling to different chemical moeities. However, UV analyses come with a number of technical challenges, that require considered instrument design to allow UV Raman to be a truly useful tool for the researcher.

  • Omnisens Optical Fiber And Cable Measurement And Quality Control

    https://www.omnisens.com/uploads/1/2/0/5/120592129/telecom-1_orig.png - Omnisens

    To provide quality control or help with the design and testing of fibers, Omnisens Vision offers fast, accurate strain and temperature measurements.Omnisens Vision is based on Brillouin scattering. In single mode fibers it produces precision readings with high spatial resolution over long distances and/or large loss test conditions. It is capable of high speed testing in dynamic situations such as flex fatigue.Its configuration flexibility makes the Omnisens Vision well adapted to a wide variety of test & measurement needs.

  • Particle Size Analyzers

    NanoBrook Series - Brookhaven Instruments Corporation

    Rapid and accurate protein & nanoparticle size distributionsMultimodal & unimodal size distribution softwareISO 13321 and ISO 22412 compliant resultsRange: < 0.3 nm to 10 mThree measurement angles: 15, 90, and 173Ideal for fast, routine sizing applications in research or quality controlHigh power 35 mW diode laserDynamic light scattering at 173 and 90Temperature control, -5 C to 110 CCompact bench top unit, USB connectionMolecular weight determination (relative and absolute through Debye plot)

  • EM Cube

    EMAG Technologies Inc..

    EM.Cube® is an industry-recognized simulation suite for electromagnetic modeling of RF system engineering problems. It features several distinct simulation engines that can solve a wide range of modeling problems such as electromagnetic radiation, scattering, wave propagation in various media, coupling, interference, signal integrity, field interactions with biological systems, etc. Using EM.Cube, you can solve problems of different sizes and length scales, varying from a few microns in MEMS devices to several miles in large urban propagation scenes.

  • Particle Sizing

    Fritsch GmbH

    REPRODUCIBLE ANALYSIS OF PARTICLE SIZE AND SHAPEStatic Light Scattering – perfect for particle sizing from 0.01 to 2100 µm!The Laser Particle Sizer ANALYSETTE 22 NanoTec is used worldwide in production and quality control, in research and development for the precise measurement of particle sizes.Dynamic Image Analysis – particle shape and size analysis in a wide measuring range 20 µm - 20 mm!The Particle Sizer ANALYSETTE 28 ImageSizer is ideal for particle shape and size analysis of powders and bulk solids as well as emulsions and suspensions.

  • Saybolt Color Analyzer

    optek

    optek’s Saybolt color analyzer is a dual wavelength light absorption sensor. Operationally, the sensor passes a white light beam through the stream to be monitored, where light absorbance is measured at two distinct wavelengths. The measuring wavelength is set to focus on or near the peak absorbance point of the “yellowness” curve, while the secondary wavelength is chosen to compensate for any influence due to light scattering (window fouling, particulate, immiscible fluids, gas bubbles, etc.). Together, the sensor yields a repeatable and reliable true color number without any sample conditioning.

Get Help