Showing results: 46 - 60 of 69 items found.
-
WIKA Alexander Wiegand SE & Co. KG
Leakage in switchgear can cause high maintenance costs and, depending on the size, can quickly become a safety risk. Thus, gas leaks must be pinpointed promptly and reliably and then eliminated. Our detection instruments are used for monitoring the air in enclosed rooms, locating leakage points and for integral leak testing. Even small quantities of SF6 gas can be detected in air.
-
Shanghai Launch Electric Co., Ltd.
FM cascaded resonant test set is used fo ron site AC voltage withstand tests on large capacitance power equipment like SF6 breakers, GIS combination electric, power cables, etc with the voltage class up to 1000KV.
-
WIKA Alexander Wiegand SE & Co. KG
Our gas density switches operate on the reference chamber principle: A chamber filled with SF6 gas serves as a reference. With environmental influences, the reference chamber behaves the same as the tank and thus does not cause any change in the switching status. The instruments are suitable for medium and high-voltage levels and can be fitted with up to 4 micro switches. They are notable for their compact dimensions and the very high leak tightness of the reference chamber.
-
WIKA Alexander Wiegand SE & Co. KG
A suitable connection technology is essential for conducting the SF6 gas from one gas compartment to another without losses and in an efficient manner. Self-sealing valves prevent the gas from escaping unintentionally. In addition to valves, the standard delivery program also includes adapters and protection caps. Robust design, high-quality materials and full leak testing of all connecting parts ensure long-term and reliable quality.
-
Eltel Industries
*For fast and accurate measurements of low resistance on Switch Contacts, SF-6 Switch Gear, Bushbars, Splices, Joints, Fuses, Breaker Contacts, and Rail Bonds.*100A DC continuous current in 4 ranges of 10A, 20A, 50A and 100A*4 1/2 digit display for higher resolution*Wide resistance range of 20µΩ to 200mΩ in 5 ranges*Suitable for operation in energized switchyard conditions*SMPS based- lightweight and portable
-
WIKA Alexander Wiegand SE & Co. KG
Discharges during switching operations in SF6 gas-filled plant lead, over time, to increased concentrations of toxic and highly corrosive decomposition products. The use of gas analysis instruments is absolutely necessary to monitor the concentration of harmful decomposition products, thus ensuring long-term plant safety. WIKA offers a complete product line for gas analytics with instruments for measuring individual decomposition products, through multi-analysers with pump-back functionality, to high-precision laboratory equipment.
-
GTU-320KVA/320KV -
Wuhan Sangao Electrical Test Installations Limit Co.
GTU high-voltage testing transformer uses SF6 as the insulating gas to separate the vacuum room from the outside,this equipment reflects the smallness in size, lighter in weight,higher voltage grade for unit,convenience in transportation and operation,It can let the large capacity and high voltage power frequency transformer arrived at the scene for the high-voltage test.
-
GTU-400KVA/400KV -
Wuhan Sangao Electrical Test Installations Limit Co.
GTU high-voltage testing transformer uses SF6 as the insulating gas to separate the vacuum room from the outside, this equipment reflects the smallness in size, lighter in weight, higher voltage grade for unit, convenience in transportation and operation, It can let the large capacity and high voltage power frequency transformer arrived at the scene for the high-voltage test.
-
CP RC -
OMICRON electronics
For HV testing OMICRON’s CPC 100 + CP RC are directly connected to the voltage transformer of the GIS, forming a resonance circuit. This reinforced “Power VT” is an integrated part of the GIS. So the need for draining and refilling any SF6 gas is eliminated. Acting as both the measuring and controlling device, the CPC 100 injects the required energy.
-
North Star High Voltage
Upgraded "bare" versions of our probes for space-saving installation into oil (or SF6) tanks are now available. These probes are similar to the VD series probes with somewhat lower accuracy at a somewhat lower cost. When installing these probes some information about the surrounding areas is required. The length of a VD-120 bare probe (120 kV) is 0.35 m. These units are threaded and can therefore be stacked into higher voltage units. The VD-60 and VD-120 are offered at 60 kV and 120 kV respectively. The bare probes are now available for use in air, but only at 60 and 1120 kV sizes.
-
GASERA ONE PULSE -
Gasera Ltd.
GASERA ONE PULSE is a versatile and easy to use multi-gas monitoring solution. It offers accurate ppb detection at an unbeatable price. It can be configured for a range of uses and is currently in use by our customers in; detecting SF6 leakage, refrigerant leakage, anesthetic gas monitoring, emissions monitoring of greenhouse gases, soil analysis, occupational health and safety, photocatalysis, animal husbandry, and fume hood performance testing.
-
GTU-800KVA/220KV -
Wuhan Sangao Electrical Test Installations Limit Co.
SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test,and for testing all GIS switchgears and GIS components such as insulators,insulating tension pole,GIS voltage transformer and so on,the PD test can be performed under the general environment because of the merits of encapsulation ,the PD level of our equipment can be lee than 3pC,and it can be added a HV bushing to perform the withstand voltage test at the same time.
-
GTU-1200KVA/600KV -
Wuhan Sangao Electrical Test Installations Limit Co.
SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test,and for testing all GIS switchgears and GIS components such as insulators,insulating tension pole,GIS voltage transformer and so on,the PD test can be performed under the general environment because of the merits of encapsulation ,the PD level of our equipment can be lee than 3pC,and it can be added a HV bushing to perform the withstand voltage test at the same time.
-
GTU-800KVA/800KV -
Wuhan Sangao Electrical Test Installations Limit Co.
SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test,and for testing all GIS switchgears and GIS components such as insulators,insulating tension pole,GIS voltage transformer and so on,the PD test can be performed under the general environment because of the merits of encapsulation ,the PD level of our equipment can be lee than 3pC,and it can be added a HV bushing to perform the withstand voltage test at the same time.
-
SIM-CB6 -
Zensol Automation Inc.
The SIM-CB6 is the circuit breaker simulator that will make you an expert in breaker testing. The SIM-CB6 enables you to simulate any type of circuit breaker (SF6, Air Blast, Oil, etc.) up to 6 contacts (2 contacts per phase), with or without closing/opening resistor contacts and control cabinets. This simulator will allow you to increase your knowledge on circuit breaker analyzer systems to ensure full efficiency once on the field.