Filter Results By:

Products

Applications

Manufacturers

Showing recent results 1006 - 1020 of 1025 products found.

  • Current Sensing Probe

    Teseq AG

    The CSP 9160 is a broadband RF current sensor probe as defined in CISPR 16-1-2. Beside the compliance measurements of asymmetrical disturbance currents as e.g. required in CISPR 16-2-1 and CISPR 22, the probe can be used in a number of diagnostic applications to measure superimposed RF currents flowing in conductors, or cable harnesses.A convenient feature of the CSP 9160 is that, from 100 kHz to 120 MHz, it has a flat frequency response with a 0 dB transducer factor, allowing voltage measurements to be read as current, directly without any correction. The probe can be easily and quickly clipped around the cable under test and the RF currents measured using an oscilloscope, spectrum analyzer, or EMI receiver. Its large aperture (25.4 mm) can accommodate most cables and can handle power lines with currents up to 50 amps.

  • Pressure Sensor Interface

    USB2251 - Validyne Engineering

    The USB2251 Pressure Sensor Interface provides real-world data acquisition for your PC via the USB port. 8 calibrated variable reluctance pressure sensor inputs are accepted by the USB2251. No external signal conditioning is required.The USB2251 includes a connector panel for sensor cables, calibration constants for each sensor , configuration and data acquisition software. The USB2251 produces a floating-point value for all readings, directly in engineering units.The USB2251 can record pressure readings up to 5000 samples per second. Combined with the fast response of the Validyne VR pressure sensors, the USB2251 is ideal for transient pressure studies. The USB2251 is compatible with the following Validyne variable reluctance pressure sensors: AP10, DP103, DP10, DP45, DP15 DP360, DP215, and DP363. Each sensor is calibrated with the USB2251 at the factory and is ready to make measurements.

  • 28-CH PPI Module

    ND-6058 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • 15-CH Isolated Digital Output Module

    ND-6056 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • 8-CH Relay Output Module

    ND-6063 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • Relay Output & Digital Input Module

    ND-6060 - ADLINK Technology Inc.

    ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.

  • Universal high voltage reference divider

    PRESCO AG

    Universal high voltage reference divider. One single unit for all voltages. Saves valuable laboratory space and set-up time. single unit vor all voltages meets IEC 60-2 for AC and DC voltages lighting impulse up to 500kV switching impulse up to 350kV impulse voltage ratio < 1% light. impulse voltage 0.5% front chopped light. imp. 2% Rated Voltages lighting impulse up to 500kV Universal High Voltage Reference Divider for Lighting Impulse Voltage of 500kV lighting impulse voltage 500kV front- chopped lighting impulse voltage 500kV switch impulse voltage 350kV AC voltage 200kVRMS DC voltagge 250kV Measurement Uncertainty according to IEC 60-2 Universal high voltage reference divider. One single unit for all voltages. According to IEC 60-2. light. imp. voltage 0.5% front chopped light. imp. 0.3% switching imp. voltage 0.5% time parameter t1, t2 3% AC voltage 0.5% AC phase 5mrad DC voltage 0.5% Unit Step Response Data partial resp. time < 12ns Universal high voltage reference divider for lighting impulse voltage of 500kV. Partial response time < 12ns experimental resp. time < 15ns partial resp. time < 12ns setting time < 150ns overshoot beta < 10% Impedances and Ratios scale factor with standard attenuator: 6300 Universal high voltage reference divider. One single unit for all voltages high voltage capacitor = 200pF high voltage resistor = 600E scale fac. without att. = 630 scale fac. with stan. att. = 6300 Technical Data About Dividers a technical paper about reference measuring system for lightning and switching impulse voltages.

  • High Speed Digital Analog

    JGB Consulting, Inc.

    The Automatic Test Equipment is designed to provide R&D and the Production floor with a high quality, reliable and easy to use Test Station comprised of COTS equipment from industry leading instrument manufactures. The measurement switching has low thermal offset allowing for micro volt measurements. The switching also accommodates both stimulus and measurement up to 5 Amps. Also to provide High Speed and Static Digital Stimulus and Response that covers LVDS, 3.3V, TTL, CMOS and Industrial logic families. For Serial communications there are SPI, I2C, RS232/485, USB and Ethernet. The system has nine programmable DC power supplies that are capable of powering both the UUT and the UUT interface separately. The system can interface with a variety of UUT’s via an ITA. Each system comes with the Imperial Test Executive, National Instruments TestStand, CVI, LabView and .NET Runtime.

  • High Performance High Power DC Electronic Load

    IT8900A/E Series - I-TECH Electronic Co., Ltd

    IT8900A/E series high performance high power DC electronic load provides three voltage ranges 150V/600V/1200V, stand-alone power from 2kW to 54kW. IT8900A/E series, with ultra-wide voltage and current range, controlled by an independent master unit. The power expands to 384kW by master-slave paralleling. Ultra-high power density, 6kW is with only 4U height. IT8900A/E series has eight (A series) / four (E series) working modes, faster loop response and current rising and falling speed, as well as dynamic mode, OCP test, OPP test, automatic test and battery test functions. Built-in CAN, LAN, GPIB, USB, RS232 and analog interfaces, etc., IT8900A/E series has full protection function, which can be applied to power battery discharge, DC charging station, on-board charger (OBC), power electronics and other power electronics products.

  • DevOps Testing Services

    ImpactQA

    The use of DevOps testing practices is aimed at bringing improved collaboration across teams and better changes in business response rate. ImpactQA follows an extensive skill set for structuring the right QA capabilities for DevOps. We are living in a fast-paced environment which comes with a shorter testing window. The inclusion of shift-left approach and an efficient team of development engineers permit quicker testing execution and improved code quality. Our continuous testing and crowd testing techniques are powerful testing methods that assist in upholding a DevOps environment within an enterprise. At ImpactQA, we deploy a systemized arrangement that regulates better time-to-market via DevOps testing solutions. Our motto is to bring augmented operational efficiency that is motivated through our DevOps testing professionals with their far-reaching expertise in Continuous Integration (CI) testing & Continuous Deployment (CD). We offer end-to-end automated solutions for sustaining Continuous Testing (CT) that functions with CI & CD tool

  • High Power DC Electronic Loads

    63200A - Chroma Systems Solutions, Inc.

    Rated power : 3kW 24kW, max. 480kW (parallel)Voltage range : 150V, 600V, 1200VCurrent range : 2000A max. per unitCC, CR, CV & CP operation modesCR+CC, CR+CV, CC+CV complex modesUp to 20 units master/slave parallel controlDynamic synchronous control in static and dynamic loadsUser defined waveform (UDW)CZ mode for turn on capacitive load simulationExternal loading current simulationAuto frequency sweep up to 50kHzReal time power supply load transient response simulation & Vpk+/- measurementUser programmable 255 sequential front panel input statusUltra high precision voltage & current measurementPrecision high speed digitizing measurement/data captureVoltage, current & Pmax measurement for OCP/OLP testTiming & discharging measurement for batteriesInstant overpower loadingShort circuit simulationSmart fan controlFull protection: OC (adjustable), OT, OP (adjustable) protection & OV warningStandard USB, optional Ethernet and GPIB interfaces

  • Post Silicon Validation Solutions

    Test Evolution Corporation

    Post-silicon validation (PSV) of first silicon tends to be an ad hoc process, stitching together protocol testers from various manufacturers to create test cases and debug issues. While IC’s are getting to market, the process is far from ideal. Leveraging the tools and methodology of pre-silicon verification into post-silicon validation is a key enabler to higher productivity. Test IP-based PSV is a paradigm shift from the way post-silicon validation is currently done. Individual protocol testers, scopes, miscellaneous equipment from various vendors, and on-chip logic are cobbled together in an attempt to create meaningful stimulus, response checking, and debugging.The problems with these ad hoc solutions:Protocol boxes from multiple vendors generally do not work together well. Each has its own driver software, programming model and debugging tools.Tool flows from pre-silicon to post-silicon to production and back are nonexistent. This makes writing tests challenging and thus generally limited in robustness. Also, debugging suspected problems is difficult across more than one interface.

  • Microprocessor Multifunction TRMS Power Meter + Harmonics Analyzer

    8100 C - KUSAM-MECO

    INPUT :• Input Voltage Range :Voltage: 55 ~ 300V AC, or 300 ~ 600V AC, 45 ~ 65Hz.P.T. Ratio Programmable upto 9999 / KV.• Input Voltage Over Range :Voltage : 200 % Continuous, 300 % of rating for 10 sec.• Input Current Range :Current : 110 % of rating. 0-1A or 0 - 5AC.T. Ratio programmable upto 9999 / 5A.Input Current Over Range:Current : 400 % Continuous, 2000 % of rating for 10 Sec.• Input Frequency : 45 Hz ~ 70 Hz.• Input Burden :Voltage 0.25 VA / Unit, Current 0.25VA / Unit, at 50 / 60HzOUTPUTDC Current: 0 20 m A DCLoad resistance drive: output drive 10 V DC maximum.DC Voltage: 0 -10 V DCLoad resistance drive: output drive 5mA maximumOutput Protection: No damage even if output is Open or Short Circuit.Output Response Time : £ 1 Sec.Digital Output : RS485 Output, Isolate Type with MODBUS RTU mode., 4800, 9600,19200Baud Rate, User Selectable.

  • Modular DC Electronic Load

    63600 - Chroma Systems Solutions, Inc.

    Max. Power : 100W x 2(Dual), 300W, 400WVoltage Range : 80V, 150V, 600V5 module mainframe Max. 2000W, load modules up to 400W/eaUp to 10 channels in one mainframe, fit for testing multiple output SMPS0.4V @ 80A (Typical) low voltage operating characteristicsFlexible CC, CR, CV and CP operation modesCZ mode for turn on capacitive load simulation (up to 50,000uF capacitance emulation)Parallel mode for high current and power application up to 2kWMulti Channel synchronous controlReal time power supply load transient response simulation and Vpk+/- measurementUser programmable 100 sequential front panel input status for user-friendly operatingOver current protection (OCP) testing functionPrecision voltage and current measurementPrecision high speed digitizing measurement/ data captureVoltage, Current and Pmax measurement for OCP/OLP testingTiming measurement for batteriesShort circuit simulationSelf-test at power-onFull Protection : OC, OP, OT protection and OV alarmEthernet, USB and GPIB interfacesUser Defined Waveforms

  • Digital Panel Mount Load Cell Meter

    MODEL DPM-3 - Transducer Techniques, Inc

    The DPM-3 is a smart Plug & Play TEDS IEEE 1451.4 compliant Digital Panel Mount Load Cell meter. Just plug in a TEDS compatible Load Cell or Torque Sensor and the DPM-3 will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the DPM-3 can be set up by simple front panel push buttons. The DPM-3 can be scaled to a full 5 digit display from 0 to 99,999 counts to read directly in engineering units such as grams, ounces, pounds, etc. The DPM-3 samples 60 readings per second (50 for 50Hz operation) for fast control response and true peak/valley reading capability. The meter has an adaptive digital filter that can automatically select the best time constant for minimum noise, yet respond rapidly to an actual change in signal level. The peak and valley values can be displayed by a push of a button on the front panel. Auto-tare allows the meter to be set to zero for any input signal level. Available options include dual relays, analog output, serial communications, and low voltage power supply.