Filter Results By:

Products

Applications

Manufacturers

Showing results: 76 - 90 of 92 items found.

  • UV Man Spectrometer

    HORIBA, Ltd.

    UV Raman (with laser wavelengths below 400nm) can be used to probe specific sample properties, and benefit from experiment properties different from typical visible Raman measurements – for example, greatly increased Raman scattering efficiency, modified laser penetration within the sample, and resonance coupling to different chemical moeities. However, UV analyses come with a number of technical challenges, that require considered instrument design to allow UV Raman to be a truly useful tool for the researcher.

  • Preclinical Imaging Modalities and Solutions

    Bruker Corporation

    Bruker offers advanced preclinical imaging solutions for a broad spectrum of application fields, such as oncology, neurology, cardiology, inflammation, infectious diseases, cancer research, functional and anatomical neuroimaging, orthopedics, cardiac imaging and stroke models. Our range of techniques includes MRI (Magnetic Resonance Imaging) , PET (Positron Emission Tomography), SPECT (Single Photon Emission Computed Tomography) micro-CT (Micro Computed Tomography), optical imaging and magnetic particle (MPI) imaging.

  • Electroacoustic Analysis System

    CRY6125 - Hangzhou JiGao Electroacoustical Science and Technology Co.,Ltd

    CRY6125 series electro-acoustic device tester is a full-featured electro-acoustic device tester with anti-noise function. Measure the performance indicators of microphones, electret microphones (microphones), microphones, receivers, earphones, headset microphone assemblies, communication caps, speakers / speakers, buzzers and other electroacoustic devices. Such as: sensitivity (SPL), impedance, distortion (THD), resonance frequency F0, quality factor Q, equivalent volume, audio power amplifier, etc., the measurement frequency can reach 10Hz ~ 65kHz .

  • Pneumatic Horizontal Shock Response Spectrum Test System

    KRD15 series - CME Technology Co. Ltd.

    KRD15 series is the state-of-the-art shock response spectrum tester that adopts compressed gas energy to provide impact energy, push the shock hammer to impact the resonance plate, and generate high energy shock. Comparing to traditional pendulum shock response spectrum tester, this machine has the advantages of high energy, stable performance, high reliability, good repeatability, easy adjustment, safety and environmental protection. It is mainly applied in the industries of aerospace, aviation and ships.

  • Electroacoustic Analysis System

    CRY6125 - CRYSOUND

    CRY6125 Electroacoustic tester is a full-featured electroacoustic device tester with resistance to environmental noises. It is designed to measure the performance indicators of microphones, electret microphones (MIC), transmitters, receivers, earphones, headset microphone assemblies, communication helmets, speakers/loudspeakers, buzzers and other electroacoustic devices, such as sensitivity (SPL), impedance, distortion (THD), resonance frequency F0, quality factor Q, equivalent volume, and audio power amplifier, etc. Its measurement frequency can be up to 10 Hz - 65 kHz.

  • Fluorescence Lifetime Imaging Microscopy (FLIM) Camera

    Toggel - Lambert Instruments BV

    Lambert Instruments today announced the introduction of its next-generation fluorescence lifetime imaging camera: Toggel. This new camera makes fluorescence lifetime imaging microscopy (FLIM) and fluorescence resonance energy transfer (FRET) faster and easier with its excellent light sensitivity, sharp images and fast image acquisition. With Toggel, Lambert Instruments aims to minimize measurement duration, automate image acquisition and simplify data analysis. These factors are of great importance to many of its customers in cell biology, cancer research and high-throughput screening.

  • Press-type Vibration Tester

    9363-PC-ESS - King Design Industrial Co., Ltd.

    This machine complies with the IEC, JIS and other 5-100Hz low-frequency specifications; applied to test the post-assembly products at end of the production line. Use resonance amplification, the product’s flaws can be screened out in advance. The operation is convenient, fast and effective.Apply Japan-imported motor; durable and safe in operation.Bellow-type damper: use special damping material that can effectively absorb vibration; allowing the test to be performed without affecting floor structure.Motor drive system is embedded in the seat; good in vibration block-out; rigidity is strong. Follow specimen to design fixture.

  • SERS (Surface Enhanced Raman Scattering) Substrate & SERS Reader – Mini Chemistry Analytic Pack

    BaySpec, Inc.

    The porous carbon SERS substrate provides not only high signal enhancement due to its strong broadband charge-transfer resonance for large chemical enhancement (as opposed to electromagnetic enhancement in traditional metal-based SERS substrates), but also extraordinarily high reproducibility or substrate-to-substrate, spot-to-spot, sample-to-sample, and time-to-time consistency in SERS spectrum (which is not possible with traditional metal-based SERS) due to the absence of "electromagnetic hot spots" by making the entire surface of the substrate "chemically hot", high durability due to no oxidization, and high compatibility to biomolecules due to its fluorescence quenching capability.

  • Electroacoustic Analysis System

    CRY6151B - CRYSOUND

    CRY6151B is a full-featured electroacoustic tester newly launched by CRY Sound. It is powerful and stable. It can measure the performance indicators of headphones (USB, Bluetooth, anti-noise), microphones (electret, MEMS, moving-coil type), headphone and microphone assemblies, receivers/headphone speakers, speakers/loudspeakers (common, Bluetooth), loudspeaker crossover devices, and other electroacoustic devices, such as sensitivity (SPL), impedance, distortion (THD), resonance frequency F0, left and right headphone balance, left and right headphone position, phase polarity, microphone current and voltage, SNR, microphone directivity, speaker's TS parameters, telephone receiving and sending loudness ratings, etc. Its test frequency range can be up to 20 Hz - 20 kHz.

  • Portable 2 Channel/4 Channel FFT Analyzer

    CF-9200/9400 - Ono Sokki

    The CF-9200 and CF-9400 are an all-in-one portable FFT analyzer. All FFT analysis operations can be performed with the integrated hard keys and capacitance type touch panel without requiring an external PC for analysis. The new, exclusively developed 100kHz high-performance analysis front-end system incorporating a 24-bit A/D converter enables easier and more reliable analysis of noise and vibration generated by plant lines, pumps, motors, automobiles, railway vehicles, home electrical appliances and devices, and electrical and electronic parts than previous models. The CF-9200 and CF-9400 also offer solutions for field workers in their FFT analysis, including the resonance and frequency characteristics of mechanical structures in a vibrating environment with electromagnetic vibrators and impulse hammers.

  • Large-Displacement Low-Frequence Vibration System

    9363-LN-100 - King Design Industrial Co., Ltd.

    This tester is designed to assess the damage made to product packaging and internal objects caused from transporting environment; to discover the packaging flaw and product’s early failure from a long-term cumulative vibration fatigue; avoid man-made transporting damage and improve product’s reliability and quality of delivered products. With the use of high-performance foot absorber, the resonance effect to floor caused by the bounce test may be waived; and can reduce the pile’s destruction to industrial plants. Two displays can make comparative display on both frequency and rpm at the same time; thus no need to switch in order to read these two values. The dual-control mode of time accumulator and counter can avoid human error resulting from the conversion. Easy to operate; no need for complicate training program.

  • Electroacoustic Analysis System

    CRY6151 - CRYSOUND

    CRY6151 Electroacoustic Analysis System is a full-featured electroacoustic device tester launched by CRY Sound. It has a history of 10 years. It is powerful and stable. It can measure the performance indicators of headphones (USB, Bluetooth, common), microphones (electret, MEMS, moving-coil type), headphone and microphone assemblies, receivers/headphone speakers, speakers/loudspeakers (common, Bluetooth), communication helmets, loudspeaker crossover devices, and other electroacoustic devices, such as sensitivity (SPL), impedance, distortion (THD), resonance frequency F0, left and right headphone balance, left and right headphone position, phase polarity, microphone current and voltage, SNR, microphone directivity, speaker's TS parameters, telephone receiving and sending loudness ratings, etc. Its test frequency range can be up to 20 Hz - 20 kHz.

  • High-acceleration Shock Tester

    DP-1200-18 - King Design Industrial Co., Ltd.

    The precise-type high-acceleration shock tester can provide all half-sine short wave specification specified in JESD22-B110. To meet them, merely change different shock rubber-pad on shock seat. The wave is complete with high repeatability, able to provide user accurate test result.Conform to different test specs such as JESD22-B110 and IEC spec.High repeatability on consecutive shock; acceleration +/- 10%; run time +/- 15%; speed deviation +/- 10%.Table’s four corner-points uniformity P160mm +/- 10%.Can add spring system to reach the requirement of extra high acceleration specification.Using high-efficiency vibration-absorbing seat pad can block out possible floor resonance and protect the factory structure.Easy in operation; no complicate training course required.Module shock rubber-pads are applied per different standards independently. And the rubber-pad lifetime can be prolonged.

  • Force Limited Vibration Testing

    National Technical Systems

    In vibration testing of high value aerospace hardware, over testing of light, high performance structures is a great concern. Discrepancies between the mechanical impedances and the force capabilities of the mounting structure and the vibration shaker can cause catastrophic structural and functional problems to test item. The effectiveness of the radar depends on it retaining its structural integrity over the entire surface of the antenna and that all its electronics are a) tested at, or near levels they will experience in its service life and b) the resonance of various parts of the radar follow those of the model. Consequently, the vibration test lab required 60 data channels to accurately verify the design of the instrument and its ability to withstand launch, cruise and deployment loads. To avoid over testing, NTS used Force Limiting Test Process using four force transducers to prevent exceeding total load of 1000 pounds.

  • HV AC Voltage Test Systems

    Fivestar HV Testing Equipment Co., Ltd.

    FSHV offers three different types of AC voltage test systems, the conventional type is AC test transformer design, mainly for testing objects of medium & low capacitance products, particularly for tests requiring stable voltage even if the load changes under voltage (corona, wet & pollution tests) or when the load is inductive (like inductive voltage transformers). Another is AC resonant test systems, according to series resonance circuit XL=XC (2πfL=1/2πfC), by setting F frequency of power supply or L inductance of reactor, generate a pure sinusoidal waveform of the test voltage, and the required input power is only 1/Q. Variable frequency type operates in a frequency range from 20Hz to 300Hz, ideal for field commissioning test of power cables and GIS/GIL. Variable inductance type outputs continuous AC voltage of power frequency (50/60Hz), mainly for factory testing of high and ultra-high voltage cables, power transformers, GIS, etc.

Get Help