Filter Results By:

Products

Applications

Manufacturers

RTD

- variable-resistance sensor measuring temperature by fluctuations in resistance.


Showing results: 181 - 188 of 188 items found.

  • Temperature Loop Control Setup

    ULP-27 - Unitech Scales And Measurements Pvt. Ltd

    Unitech’s Temperature Control Loop Setup is basically a PC based PID controller setup used for closed loop and open loop analysis of temperature process system. The setup comprises of RTD temperature Sensor. The water flows through the Rotameter and Process tank to which a heating coil is fitted. The heater is controlled by a Thirstier drive. The Thirstier drive is connected to PID controller. The manual control valve can control the water flow. The system is mounted on a tabletop model with all necessary Piping. Water at approx. 100 LPH has to be supplied to a system externally. The electronic panel comprises of ADC/DAC card with RS-232 interfaces.

  • Temperature Input Module For Remote I/O

    NI

    The Temperature Input Module for Remote I/O features a features a thermocouple input range of ±100 mV and a voltage input range of ±5 V. It also has an adjustable filter time for improved measurement quality and optional external CJC or PT100 RTD measurements.A remote I/O system consists of an EtherCAT bus coupler and individual modules mounted on a DIN rail. You control the Temperature Input Module for Remote I/O from a real‐time controller, such as a CompactRIO Controller or an Industrial Controller. You can use remote I/O hardware to add low‐cost I/O for simple tasks while your controller handles advanced tasks such as image processing, motion control, and high‐speed or specialty measurements.

  • Telemetry

    ESI Technology Ltd

    Single channel system, offering wireless transfer of a single analogue signal, either 4-20mA or DC voltage. Mixed signal radio telemetry solution. Analogue I/O: 2x 2-40mA or DC Voltage. Digital I/O: 2x volt free or optional pulse counting required. Multi-channel radio telemetry system, 4 Analogue and 8 digital inputs. Significant signal connectivity and data transfer in a standard package.12 I/O channels allow greater signal monitoring capability SENSOR LINK Compact wireless telemetry link for any strain gauge sensor or RTD. Transmissions distance 1 to 300 meters. Licence free radio operation.16 bit ADC resolution.

  • Power Meters and Calibration Cells

    Sciencetech, Inc.

    The Solar Reference Cell consist of a 20 x 20 mm monocrystalline silicon Photovoltaic Cell encased in a 92 x 70 x 16 mm metal enclosure with a protective quartz window and a temperature sensor. The temperature sensor is a 100 ohm platinum Resistance Temperature Detector (RTD).The Solar Reference Cells come with a Certificate of Calibration and compatible set of connecting cables. The following parameters of the reference cell are certified: Isc, Imax, Voc, Vmax, Pmax, Area, Fill Factor and Efficiency. The certification is accredited by NIST to the ISO-17025 standard and is traceable both to the National Renewable Energy Laboratory (NREL), and to the International System of Units (SI). A compatible cable set is also supplied with each Solar Reference Cell.

  • 4-Channel Datalogging Thermometer

    Extech SDL200 - Extech Instruments Corporation

    The SDL200 records data on an SD card in Excel format. 4-Channel datalogging with 6 Thermocouple types (J, K, E, T, R,S) and 2-Channel datalogging with RTD (Pt100Ohm) probes. Displays [T1, T2, T3, T4] or differential [T1-T2] readings. Offset adjustment used for zero function to make relative measurements. Stores 99 readings manually and 20M readings via 2G SD card. Records readings with real date and time stamp. User programmable sampling rate from 1 to 3600 seconds. Min/Max, Data Hold, Auto Power Off. Complete with 6 AA batteries, four general purpose Type K bead wire temperature probes, SD card, and hard carrying case.

  • REM-11120, 4-Channel Thermocouple, 1-Channel Voltage, Temperature Input Module for Remote I/O

    784750-01 - NI

    4-Channel Thermocouple, 1-Channel Voltage, Temperature Input Module for Remote I/O - The REM‑11120 is a temperature input module for remote I/O. Remote I/O systems are low-cost, modular systems for simple machine control and measurements. A remote I/O system consists of an EtherCAT bus coupler and individual modules mounted on a DIN rail. You control the REM‑11120 from a real-time controller such as a CompactRIO Controller or an Industrial Controller. You can use remote I/O hardware to add low-cost I/O for simple tasks while your controller handles advanced tasks such as image processing, motion control, and high-speed or specialty measurements. The REM‑11120 also has an adjustable filter time for improved measurement quality and optional external cold junction compensation (CJC) or PT100 resistance temperature detector (RTD) measurements.

  • Digital Multimeters

    Tektronix, Inc.

    *5½-digit resolution to 8½-digit resolution DMMs*6ppm basic voltage measurement accuracy on the 8½-digit DMM for calibration laboratories*Fast, 1 Msample/s sampling speed to capture complex, low level current profiles from IoT devices or other wireless devices*Sensitivity of 1 µΩ and 1 pA to test low power devices for research, design, and manufacturing test*A wide range of measurement functions such as DC and AC volts, DC and AC current, two- and four-wire Ohms, continuity, frequency, period, RTD, thermistor, and thermocouple temperatures, diode test, and capacitance*Numerous interface options including LAN/LXI, USB-TMC, GPIB, and RS-232 for data acquisition and automated testing*Intelligence to execute tests and create customized measurements with minimal PC interaction*Measurement expansion up to ten channels

  • Multifunction Calibrator 15 ppm Basic Accuracy

    MC142 - Powertek LLC

    Multifunction calibrator MC142 is a precision voltage, current and power calibration source serving as a measurement standard in calibration laboratories and production lines; where verification of electrical measurement equipment & sensors is required. It can be used for calibration and adjustment of meters measuring voltage, current, power, resistance, capacitance and frequency. Internal harmonic and non-harmonic signals make it possible to test electrical performance of meters using signals with various crest factors. Frequency modes enable selection of frequency, amplitude and duty cycle of the output signal. These are suitable for basic calibration of digital and analog oscilloscopes along with transient recorders. The calibrator is equipped to measure temperature with TC and RTD temperature sensors. Its built-in multimeter can be used independently or simultaneously with the calibrator output. Testing of transducers of various types, regulators and sensors can be performed, without the necessity to use any other measuring instrument.