Filter Results By:

Products

Applications

Manufacturers

Particulate

subatomic or minute speck of matter


Showing results: 46 - 57 of 57 items found.

  • Particle Sensor

    HPM Series - Honeywell Sensing & Control

    The Honeywell HPM Series Particle Sensor is a laser-basedsensor which uses the light scattering method to detectand count particles in the concentration range of 0 g/m3to 1,000 g/m3 in a given environment. A laser light sourceilluminates a particle as it is pulled through the detectionchamber. As particles pass through the laser beam, the lightsource becomes obscured and is recorded on the photo orlight detector. The light is then analyzed and converted toan electrical signal providing particulate size and quantity tocalculate concentrations in real time. The Honeywell particlesensor provides information on the particle concentration forgiven particle concentration range.

  • Zeta Potential Analyzers

    Brookhaven Instruments Corporation

    Almost all particulate or macroscopic materials in contact with a liquid acquire an electronic charge on their surfaces. Zeta potential is an important and useful indicator of this charge which can be used to predict and control the stability of colloidal suspensions or emulsions, for example. The greater the zeta potential the more likely the suspension is to be stable because the charged particles repel one another and thus overcome the natural tendency to aggregate. The measurement of zeta potential is often the key to understanding dispersion and aggregation processes in applications as diverse as water purification, ceramic slip casting and the formulation of paints, inks and cosmetic

  • Emission Measurement Systems

    HORIBA, Ltd.

    HORIBA develops and manufactures products and systems for testing of all types of engines: heavy-duty to small utility, onroad systems to non-road, marine to locomotive, automotive to aeronautic. Our extensive product line includes analyzers, analytical systems, dilution/ sampling systems, dynamometers and automation systems to assist engineers to evaluate and advance: exhaust gas and particulate emissions, engine performance, fuel economy, fuelcell reformer efficiency, other parameters of engine and vehicle.

  • On-board Emissions Measurement System

    OBS-ONE PM unit - HORIBA, Ltd.

    OBS-ONE PM unit is the industry-leading on-board Particulate Matter (PM) measurement system. It collects PM on a filter paper, using a partial flow gravimetric sampling method, while simultaneously measuring real-time PM. A key feature of this design is the use of a venturi flow meter which enables reliable proportional sampling and accurate exhaust gas flow measurement under transient flow conditions. Combine the GAS unit and PM unit to perform certification tests on heavy duty and non-road vehicles.

  • Ultrasonic Exhaust Flow Meter for Real-time Measurement of Vehicle/Engine Exhaust Flow

    EXFM-ONE - HORIBA, Ltd.

    EXFM-ONE employs an ultrasonic method for measuring exhaust gas flow rates directly from a vehicle or engine. The unit can be used for various applications such as real time mass measurement of raw exhaust gas combined with MEXA-ONE (Motor Exhaust Gas Analyzer), or for Particulate Matter/emission measurement combined with partial flow dilution system such as MDLT (Partial Flow Dilution Tunnel) or BMD (Bag Mini Diluter). Fuel consumption evaluation is also available when EXFM-ONE is paired with an optional air-to-fuel ratio (AFR) analyzer.

  • On-board Emissions Measurement System

    OBS-ONE GS Unit - HORIBA, Ltd.

    OBS-ONE is the latest Portable Emissions Measurement System designed for engine/vehicle certification under real road conditions.It measures concentrations of emissions (CO, CO2, THC, NOx, NO2), particulate matter, air-to-fuel ratio, exhaust flow rate, GPS data, environmental conditions (atmospheric temperature, humidity and pressure) and calculates mass emissions.OBS-ONE features the highly adaptable, intelligent operating platform called “HORIBA ONE PLATFORM” which integrates other ONE series product data and optimizes test cell operation.

  • Automotive Diagnostic& Analysis System

    MaxiCOM MK808BT - Autel

    Featuring the powerful Cortex-A9 processor, and a 7.0 inch LCD capacitive touchscreen, based on the Android multitasking operating system, and combined with the ability to quickly read and clear DTCs for all available modules of the majority of the makes and models on the market, the MaxiCOM MK808BT is your ideal auto diagnostic and service tool. MK808BT provides you with superior special functions, including Oil Reset, EPB(Electronic Parking Brake), SAS (Steering Angle Sensor), BMS (Battery Management System), and DPF (Diesel Particulate Filter).

  • Specialty Products

    MaxiCheck MX808TS - Autel

    Together with the ability to quickly read and clear DTCs for all available modules of the majority of the makes and models on the market, MaxiCheck MX808TS provides you with superior special functions, including Oil Reset, EPB (Electronic Parking Brake), SAS (Steering Angle Sensor), BMS (Battery Management System), DPF (Diesel Particulate Filter) and IMMO. In addition to OBD II diagnostics and special service, MX808TS enables you to carry out complete TPMS functions, including TPMS health check, sensor activation & programming and TPMS relearn.

  • Chemiluminescence 03 Analyzer

    Model T265 - Teledyne Advanced Pollution Instrumentation

    The Model T265 is the only commercially available US EPA Federal Reference Method for Ambient Ozone Monitoring according to the latest US EPA regulatory rules for O3. The instrument uses Chemilumescence with Nitric Oxide (NO) as a reagent, making is safe, stable, and effective for all applications. The NO-CL method for Ozone has several advantages over the conventional UV absorption technology, including the avoidance of positive and commonly found interferrents such as VOCs, fine particulates, Mercury, turpines, ClO2, and others. If these pollutants are present in the atmosphere, it can cause UV absorption analyzers to give an artificially high Ozone measurement. The innovative T265 combines speed of response, sensitivity and stability of our proven nitrogen oxide analyzer, with a simple user interface, to provide reliable ozone measurements under the harshest conditions.

  • Particle Counters

    PCE Instruments

    A particle counter is a useful tool for monitoring indoor air quality (IAQ) in clean rooms and workplaces, as a particle counter measures the concentration of particles in the air. While a particle counter won't identify specifically what kinds of dusts or particulates are present in the air, a particle counter will identify how many airborne particles of a certain size are present in the environment. A conclusion is then drawn based on the known materials in the area and the corresponding airborne particle sizes of those materials. Here at PCE, We can offer you a wide range of dust particle analyzers to suit your needs.

  • Automated Filter Tester

    8130A - TSI Inc.

    The Automated Filter Tester Model 8130A continues to be the best solution for testing particulate respirator filters, disposable filtering face pieces, and a wide assortment of filter media. The TSI filter testers have been used in quality control and manufacturing by leading filter and filter media manufacturers and test centers around the world for more than 20 years. Based on TSI's established model 8130, the world's most-used filter tester, model 8130A now offers higher sensitivity and resolution - up to 99.9999 percent efficiency - at a lower cost of ownership due to the new serviceable photometers inside. The model 8130A features a high degree of automation and self-diagnostics that greatly simplifies operation, increases throughput, and improves overall measurement performance. Whether looking for a stand-alone tester to check a few filters per day or need to integrate a tester in an automated, high-volume production line, the model 8130A is up to the challenge.

  • Sand and Dust Testing

    National Technical Systems

    NTS operates some of the largest and most accurate sand and dust testing chambers available in the industry. We can accommodate parts in excess of 8 ft3 (0.25 m3) and comply with the requirements of various regulatory standards. While sand or dust circulate at up to 40 mph (65 kph) we can modify the test according to your special requirements, including running at temperatures of up to +200°F (+95°C). A calibrated “hopper” which assures that an adequate amount of contaminant is entering into circulation manages the input to the chambers. In addition to measured inputs, NTS employs an electronic beam, which determines that there is the right mixture of sand or dust and air in the test medium at any given time. This enables our technicians to adjust for loss in real time, and make corrections to ensure that the test article is exposed to the harmful particulate matter for the requisite amount of time.

Get Help