Filter Results By:

Products

Applications

Manufacturers

Model

construction of a concept.

See Also: Modeling, Modelling, Modelers, Human Body Model, Charged Device Model


Showing results: 436 - 450 of 3994 items found.

  • High Temperature Self-Supporting Furnace Extensometers (1200 C)

    Model 3448 - Jinan Testing Equipment IE Corporation

    Epsilon developed this unique high temperature extensometer for testing metals, ceramics, and composites at the high temperatures produced by furnaces and induction heating systems. A combination of features make these extensometers easier to use and better in performance than other similar high temperature extensometers.The units are held on the specimen by light, flexible ceramic fiber cords. These make the extensometer self-supporting on the specimen. No furnace mounting brackets are required. The side load on the test sample is greatly reduced because of the self-supporting design and light weight of the sensor. Most materials testing furnaces with a side cut-out for an extensometer will readily accept a Model 3448. For induction heating systems, a different ceramic cord placement allows the extensometer to easily pass between the coils.The combination of radiant heat shields and convection cooling fins allow this model to be used at specimen temperatures up to 1200℃ (2200°F) without any cooling. An optional tiny air fan does enhance stability at the highest temperatures and is recommended for the highest accuracy and for tests with small elongations. The fan comes with a magnetic base for support so it can be mounted at any convenient location near the extensometer. Fan cooling is not generally needed for induction heated systems. High purity alumina ceramic rods are used. These are available in lengths as required to fit your furnace. A spare set is included with every extensometer. Specify chisel, vee chisel or conical contact points as desired.Most units operate equally well in tension and compression. Thus tensile, compression and cyclic tests like low cycle fatigue can all be performed with a single unit.For vacuum furnaces, special models are available. Epsilon can also provide a radiant heat transfer cooled version. This requires that the extensometer module be surrounded by a water cooled enclosure with a front slot for the ceramic rods.

  • Paramagnetic O2 Analyzer Optional CO2 Sensor

    Model T802 - Teledyne Advanced Pollution Instrumentation

    The Model T802 O2 uses the proven paramagnetic measurement principle, coupled with state of the art microprocessor technology, to provide accurate and dependable measurements of Percent-Level O2.Paramagnetic technology is non-depleting, which means that there are no consumable parts, and ensures a consistent performance over time. The selectivity of the paramagnetic measurement for oxygen means that there is little or no interference from other common background gases. The T802 offers a stable and inherently linear measurement of oxygen, making it possible to calibrate the analyzer by checking only two points. There is no requirement for a reference gas during operation.

  • Extensometers for Indirect Tensile Testing of Asphalt

    Model 3911 - Jinan Testing Equipment IE Corporation

    For indirect tensile testing, such as for resilient modulus, these extensometers measure the lateral deformation of specimens. They are self-supporting on the sample and clip on in seconds. The traditional way this deformation has been measured was prone to errors caused by slight rocking of the sample as it is loaded. The self-supporting design of the Model 3911 eliminates this problem. This unit will handle the dynamic pulse requirements of resilient modulus testing.The speed of mounting makes test set-up much faster than with the older method. The pivot mounting used ensures that the specimen contact pads meet the often uneven asphalt surface as well as possible. The measuring range options available allow a wide range of testing, yet can easily measure the sometimes very small displacements required.The Model 3911 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.

  • High Elongation Extensometers

    Model 3800 - Jinan Testing Equipment IE Corporation

    The main body of this unique extensometer remains stationary during testing, held in position by the adjustable magnetic base included. Only the very light, small traveling heads move as the sample elongates during a test. These attach to the sample with small spring clips. Each head pulls a cord out from the extensometer as the head moves. These models use high precision, low friction potentiometers, and, as a result, have a wide range of factory selectable outputs. The extensometer is driven by an excitation voltage and has output proportional to the input. They can be provided with high level outputs (approximately 2-8 VDC) or ones that mimic strain gaged devices (2-4 mV/V). When set to mimic strain gaged extensometers, the Model 3800 can be used with virtually any signal conditioning electronics designed for strain gaged sensors. The potentiometers employ a hybrid wire wound around conductive plastic, which provides excellent long term stability. The output from the extensometer is readily interfaced with most existing test controllers, and may be directly input to data acquisition systems and chart recorders. Please let us know at the time of order what type of output and connector you require.

  • UV Fluorescence Sulfur Dioxide Analyzer​

    Model T100 - Teledyne Monitor Labs

    The Model T100 uses the proven UV fluorescence principle, coupled with a state of the art user interface to provide easy, accurate, and dependable measurements of low level SO2.Exceptional stability is achieved with the use of an optical shutter to compensate for PMT drift and a reference detector to correct for changes in UV lamp intensity. A hydrocarbon ‘kicker’ and advanced optical design combine to prevent inaccuracies due to interferents.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel using NumaView™ Software, or via RS232, Ethernet, or USB com ports, either locally or by remote connection using the included NumaView™ Remote PC Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.The Model T100 comes with NumaView ™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView ™ Software. ​

  • Electrostatic Chuck Optimizer

    Model 640 - TREK, INC.

    Trek’s Model 640 Electrostatic Chuck Optimizer system is a diagnostic tool which enables evaluation and optimization of waveforms/voltages for electrostatic chucks/clamps in order to minimize de-clamp time, maximize clamp force, and achieve optimum wafer processing for ESC systems. Model 640 combines two amplifiers (for two-phase voltage combinations) and a waveform generator, which can be independently programmed and configured to investigate, research, and discover the perfect power supply and waveform recipe to efficiently drive an ESC application. An electrostatic voltmeter (ESVM) is included to monitor residual voltage from the clamping/de-clamping process.

  • Autocompute LCR-Q Meter Sorter

    Model 4912 / 4912PR - Aplab Limited

    - Microprocessor based Fully Automatic L, C, R, Q and D measurement- Autoranging with Direct Digital Readout- 4 Terminal Measurement Technique- No Tuning or Balancing- Series or Parallel Equivalent Measurement- Absolute Value and Nominal Value with Percentage Tolerance- Single / Multiple Parameters Check During Component Sorting- Feather Touch Keys with Audio Feedback- Thermal Shut Down for Overheat Protection- Special Mechanism for Fast and Easy Insertion and Removal of Test Component- Low Cost and Portable- Component Sorting on Absolute or Nominal Value Basis with a Percentage Tolerance- Aplab Model 4912PR is Remote Programmable Auto Compute LCR-Q Meter Sorter, Which can be Programmed through GPIB, RS232 or SPIB Interface

  • 2-Channel 3.6 GHz or 4-Channel 1.8 GHz 12-bit A/D with DDC - 6U VPX

    Model 58641 - Pentek, Inc.

    - Ideal radar and software radio interface solution- Two 1-Channel mode with 3.6 GHz, 12-bit A/Ds- Four 2-Channel mode with 1.8 GHz, 12-bit A/Ds- Programmable one-channel DDC (digital downconverter)- 4 GB of DDR3 SDRAM- PCI Express (Gen. 1 & 2) interface up to x8- µSync clock/sync bus for multiboard synchronization- Optional user-configurable gigabit serial interface- Optional LVDS connections to the Virtex-6 FPGA for custom I/O- Ruggedized and conduction-cooled versions available- Synchronize up to twelve modules with Model 9192 System Synchronization and Distribution Amplifier- 1U Rack-mount

  • 1-Channel 3.6 GHz or 2-Channel 1.8 GHz 12-bit A/D with Virtex-6 FPGA - 6U VPX

    Model 57640 - Pentek, Inc.

    - Ideal radar and software radio interface solution- Supports Xilinx Virtex-6 LXT and SXT FPGAs- One 1-Channel mode with 3.6 GHz, 12-bit A/Ds- Two 2-Channel mode with 1.8 GHz, 12-bit A/Ds- 2 GB of DDR3 SDRAM- PCI Express (Gen. 1 & 2) interface up to x8- µSync clock/sync bus for multiboard synchronization- Optional user-configurable gigabit serial interface- Optional LVDS connections to the Virtex-6 FPGA for custom I/O- Ruggedized and conduction-cooled versions available- Synchronize up to twelve modules with Model 9192 System Synchronization and Distribution Amplifier- 1U Rack-mount

  • 1-Channel 3.6 GHz or 2-Channel 1.8 GHz 12-bit A/D with DDC - 6U VPX

    Model 57641 - Pentek, Inc.

    - Ideal radar and software radio interface solution- One 1-Channel mode with 3.6 GHz, 12-bit A/Ds- Two 2-Channel mode with 1.8 GHz, 12-bit A/Ds- Programmable one-channel DDC (digital downconverter)- 2 GB of DDR3 SDRAM- PCI Express (Gen. 1 & 2) interface up to x8- µSync clock/sync bus for multiboard synchronization- Optional user-configurable gigabit serial interface- Optional LVDS connections to the Virtex-6 FPGA for custom I/O- Ruggedized and conduction-cooled versions available- Synchronize up to twelve modules with Model 9192 System Synchronization and Distribution Amplifier- 1U Rack-mount

  • 4-Channel 200 MHz A/D with 1532 DDCs, Kintex UltraScale FPGA - 6U VPX

    Model 58865 - Pentek, Inc.

    - Jade Xilinx Kintex UltraScale FPGA Products and Navigator Design Suite Software Video- Jade Xilinx Kintex UltraScale FPGA Family Brochure- Complete software radio receiver solution for extremely high channel-count applications- Uses Xilinx Kintex UltraScale KU035 FPGAs- Four 200 MHz 16-bit A/Ds- Eight wideband DDCs (digital downconverters)- Up to 1524 narrowband DDCs- Sample clock generation and synchronization to an external system reference- Ruggedized and conduction-cooled versions available- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe

  • 2-Channel 200 MHz A/D with 766 DDCs, Kintex UltraScale FPGA - 6U VPX

    Model 57865 - Pentek, Inc.

    - Jade Xilinx Kintex UltraScale FPGA Products and Navigator Design Suite Software Video- Jade Xilinx Kintex UltraScale FPGA Family Brochure- Complete software radio receiver solution for extremely high-channel-count applications- Uses Xilinx Kintex UltraScale KU035 FPGAs- Two 200 MHz 16-bit A/Ds- Four wideband DDCs (digital downconverters)- Up to 762 narrowband DDCs- Sample clock generation and synchronization to an external system reference- Ruggedized and conduction-cooled versions available- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe

  • High Temperature Un-Cooled Extensometers (700 C)

    Model 7642 - Jinan Testing Equipment IE Corporation

    These extensometers use a high-temperature capacitive sensor and do not require any cooling. They will operate up to the maximum temperature limit of most environmental chambers used in materials testing. The Model 7642 is ideal for testing composites, metals and high temperature polymers in tensile, compression or cyclic testing. All units can be displaced in both compression and tension. The extensometer is supplied with the advanced DT6229 controller. The standard output is 0-10VDC analog signal, factory calibrated with the extensometer. This system provides a number of functional enhancements, including high speed digital output, built in calibration and tare functions, analog and digital filters, and more.

  • High-Speed High-Voltage Power Amplifier

    Model 20/20C-HS - TREK, INC.

    The Model 20/20C-HS is a DC-stable, high-speed, high-voltage power amplifier used in industrial and research applications. It features an all solid- state design for high slew rate, wide bandwidth and low noise operation. The four-quadrant, active output stage sinks or sources current into reactive or resistive loads throughout the output voltage range. This type of output is essential to achieve an accurate output response and high slew rate demanded by a variety of loads such as highly capacitive or reactive loads. It is configured as a non-inverting amplifier.

  • High-Speed High-Voltage Power Amplifier

    Model 10/40A-HS - TREK, INC.

    The Model 10/40A-HS is a DC-stable, high-speed, high-voltage power amplifier used in industrial and research applications. It features an all-solid-state design for high slew rate, wide bandwidth and low-noise operation. The four-quadrant, active output stage sinks or sources current into reactive or resistive loads throughout the output voltage range. This type of output is essential to achieve an accurate output response and high slew rate demanded by a variety of loads such as highly capacitive or reactive loads. It is configured as a non-inverting amplifier.

Get Help