  • Low Power Wireless Gas Detector

    CX - Teledyne Gas & Flame Detection

    Model CX sensors are equipped with standard analog 4-20mA, and Modbus™ RTU RS-485 outputs and can be used with SmartWireless Site Sentinel CX/CXT controllers. The CX is a very low power device making it an ideal choice for a battery powered detector (optional) in applications where power is unavailable or not economically feasible.CX gas detection sensors are easily and economically deployable in both permanent and temporary installations. These low power sensor assemblies utilize electrochemical technology for a long list of toxic gases.​​​​​​​​​​​​​​​​​​​​

  • Fixed Gas Detectors

    700 Series - Teledyne Gas & Flame Detection

    The sensor electronics are completely protected and immune to water ingress and corrosion. The sensor elements are all plug-in components and can easily be replaced in the field. Operator interface is non-intrusive via a small handheld magnet. Configuration and routine calibration is intuitive and menu driven with fully scripted instructions. Sensor status is displayed on a built-in alphanumeric LED display. The 700 Series intelligent sensor modules feature dual redundant outputs, a linear 4-20 milliamp analog signal and a Modbus RS-485 serial output.

  • Program Controlled Safety Tester

    HopeTech

    program-controlled safety tester includes CHT9910 / 9912/9922; it has AC / DC withstand voltage test and insulation resistance test function; it has 6 groups of test modes and can realize programmable test.AC / DC voltage output 10V ~ 5KV / 6KV, insulation resistance test range: 100KΩ ~ 99GΩ, meanwhile, it has arc detection and over power detection functions. Optional RS485 interface, you can easily experiment with instrument networking through MODBUS communication protocol.

  • Temperature & Humidity Transmitter

    HTO - Chuan Sheng Electronics Co., Ltd.

    - CO2 measuring element: NDIR Sensor 2- CO measuring element: Electrochemical sensor- Temperature/Humidity sensing element : CMOS sensor- Analog output option:4~20mA or 0~10V- Communication output option:RS485 Modbus RTU- Configured by PC with free software via USB cable (option)- Present value offset adjustable- Inside buttons for adjust output parameters- LCD backlight color to Indicated CO/CO concentration 2- Temperature measuring range can be -50~100℃ via USB console port to setting

  • Dual Gas Detector

    MGS-550 - Bacharach, Inc.

    Bacharach’s advanced MGS-550 Dual Gas Detector can utilize any combination of sensor technologies, including electrochemical, semiconductor (MOS), catalytic bead or infrared, in a single platform for unparalleled detection capability. It meets ASHRAE 15 and EN 378 requirements. The MGS-550 can easily be connected to any central control system using the current and volt analog output or the Modbus RTU interface. With three user assignable relays, it can also function as a stand-alone unit without the need to wire alarm devices back to a central system.

  • 6 Digits Process Meter

    A6-PR - Chuan Sheng Electronics Co., Ltd.

    A6-PR 6 Digits Process Meter has been designed with high accuracy measurement, 6 digit display, flexible I/O functions and communication port for process measuring application.There are also build in 4x External Control Inputs, and can option 4x Relay outputs, 1x Analog output and 1x RS485 (Modbus RTU Mode) communication port with multi-functions such as control, alarm, re-transmission and communication for a wide range of industrial applications.There was designed the zero tracking and stable tracking function in programming level.According to the application, user can set the function to get the suitable reading.

  • Compact Ultrafast 50-50,000 sccm Mass Flow Controller/Meter

    C-Series - MKS Instruments

    The C-Series Mass Flow Controller (MFC) is a compact, fast-response model using a Micro-Electro-Mechanical Systems (MEMS) based flow sensor for non-corrosive gas applications. It is available in Full Scale flow rates from 50 sccm to 50 slm (N2 equivalent) with a control range from as low as 0.1% of Full Scale up to 100% of Full Scale and is also available as a flow meter. Analog (0 to 5 VDC) or digital (RS485 or Modbus TCP/IP) communications interfaces are available. Required power supply voltage is 24 VDC nominal.

  • Master And Slave

    Smart I/O - Imperious Technology Inc.

    An I/O server is a software which controls and monitors one or more PLCs /RTU's using various communication protocols.Our I/O servers are built on highly optimized Windows 32bit platform. They are capable of handling very large scale SCADA systems with minimal impact on CPU usage, resulting in effective timing and usage of available hardware.Currently, we have Master and Slave solutions for DNP3 and Modbus (ASCII, RTU, TCP). Please select the appropriate tab above for more informaiton.If you are looking for a specific I/O Server, please contact us with your needs.

  • Digital Panel Meter

    VAM - Chuan Sheng Electronics Co., Ltd.

    VAM Voltage & Current Meter has been designed with high accuracy dual channels(isolated) measurement, dual display and communication of 0~600V and 0~10A for DC/AC/TMRS. In compact size(48 x 96mm)● Build in mathematic function such as Addition / Subtraction / Multiplication / Division / high or low selector in 2 channels input to meet various testing equipment inquiry.They are also build in 4 Relay outputs, 1 Analogue output and 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of industrial applications.

  • 4 2/3 Strain Gage Meter

    CS2-SG - Chuan Sheng Electronics Co., Ltd.

    CS2-SG Strain Gauge Indicator has been designed with high accuracy measurement, display and communication of DC signal 0~1.0/~4.0mV or 0~10.0/~40.0mV as like as Load Cell or Strain Gauge.The meter supports Field Calibration function. It can be calibrated with sensor(Load Cell/Strain Gauge) to meet machinery structure.They are also building in 4 Relay outputs, 3 External Control Inputs, 1 Analogue output and 1 RS-485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of machinery and testing equipments applications.

  • 4 2/3 Strain Gage Meter (1/32 DIN)

    CS3-SG - Chuan Sheng Electronics Co., Ltd.

    CS3-SG Strain Gauge Indicator has been designed with high accuracy measurement, display and communication of DC signal 0~1.0/~4.0mV or 0~10.0/~40.0mV as like as Load Cell or Strain Gauge.The meter supports Field Calibration function. It can be calibrated with sensor(Load Cell/Strain Gauge) to meet machinery structure.They are also building in 2 Relay outputs, 1 External Control Input, 1 Analogue output or 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission or communication for a wide range of machinery and testing equipments applications.

  • Gas & Flame Detection System

    Syntel - Teledyne Gas & Flame Detection

    Syntel is an addressable loop system suitable for use in zone 1 and 2 hazardous areas. The complete addressable loo is fault tolerant operating normally with a short or open circuit. Syntel does not have a CPU, so there is no common failure point. It includes a standard OPC interface and can also be supplied by Modbus allowing easy integration with third party systems.Syntel stores alarm and calibration information in distributed non-volatile memory, hence there is no reliance on a centralized system.Syntel is ideal for installations where there is the possibility for future expansion. The system architecture allows very low cost expansion as cable runs to a central location are not needed.

  • Multi-Function Power Transducer

    TD2418B - Chitai Electronic Corporation

    The TD2418B is a micro-process based transducer with a 16 bits CPU (Center process unit) and equipped with full-digitized measuring, calibrating and output functions.TD2418B not only can take the place of several static con-verters and measuring instruments (V, A, W, PF, VAR, WH, VARH, Hz) by single unit, but also have some special function such as Maximum measuring, Minimum measuring and comparator output. In communication, we use the most convenient and the easiest RS232 or RS485 as our standard output port, besides, we adopt Modbus Protocol, one of the most popular protocol in the world, as our standard protocol.

  • Networked Absolute Inclinometer

    T7 - U. S. Digital

    The T7 is available in several interface and protocol options. The physical interface can be RS232, RS485 or US Digital's CAN (Controller Area Network). The protocol can be either US Digital's serial protocol or Modbus RTU. The RS232 version supports a single T7 with up to 100 ft of cable. For users that need longer cable lengths or multiple T7s on a single bus, the RS485 or US Digital CAN (Controller Area Network) version can be used. The USD-CAN protocol allows a network of up to sixty-four T7s to be connected to a single host. Power for each T7 is supplied over the CAN network cable. The host accesses the USD-CAN T7s through US Digital's low cost CANA-232/CANA-485 adapter module. This module allows the host to access each T7 on the network using simple, easy serial port commands, just like the RS232 version. The RS485 version supports up to 32 T7s on the bus.

  • Multifunctional Meter

    CPM-80 - Chuan Sheng Electronics Co., Ltd.

    CPM-80 multifunction power analyzer provide high accuracy single phase and three-phase energy measuring and displaying, energy accumulating, power quality analysis, data logging and data communication. CPM-80 series meters are able to measure bidirectional, four quadrants kWh and kVarh. It provides maximum/minimum records for power usage and power demand parameters. Hardware standard built in a RS485 Modbus communication port , 4 Digital inputs, 2 Relay outputs, LCM and 2MB flash for data-logging. In addition , also provide TOU , voltage and current THD, harmonics up to the 63rd and auto wiring change via software .