PoliSpectra® Quad -
HORIBA, Ltd.
Horiba’s OEM Polispectra Quad spectrometer is an integration of four VS70 spectrometers built around Horiba JY Type-IV flat-field aberration-corrected holographic concave gratings. This high throughput VIS spectrometer with 4 fiber inputs provides simultaneous acquisition of 4 channels at high speed with minimal crosstalk. The main electronics board is designed to read the two CCDs on the system simultaneously and provides 1-8X binning capability. This OEM system is a unique and innovative approach to drastically reduce the cost per channel.
-
Series RKE -
Kepco, Inc.
These lightweight (less than 7 lbs.), compact (less than 160 cubic inches), fully enclosed/shielded power converters deliver either 24, 36 or 48 volts d-c, to run distributed power systems, motors, actuators or heaters. Their universal a-c input (85-265V a-c) is at home with either 115V a-c or 230V a-c, though they produce significantly more output at the higher input voltage, and should be run from 200-240 volt mains wherever possible.
-
Labodam
Labodam Octane Number and Cetane Number Testers are portable devices for rapid petroleum products quality monitoring in fields and lab environment conditions. Glass detector has a built in element sensitive to fuel sample temperature detection. The instrument electronic computing module processes detector signals, performs all necessary calculations, and constantly tests the main function modules. It is ideal used in the determination of octane, cetane numbers, our point depressants and break down time in the oil and petroleum industries.
-
Ducommun Inc
Ducommun millimeter wave products include ACH, ARH and ALC series circular, rectangular gain horn antennas and lens corrected horn antennas for system applications. Low side lobes, ridged configuration and low cost are the main features of these antennas. The standard gain value and half power beamwidth at mid-frequency point of each waveguide band are 23 dBi and 9 degrees, respectively. Other gain values are available as customer order. These antennas cover the frequency range of 18 to 110 GHz.
-
CMM-60 -
Sonel S.A.
The CMM-60 multimeter allows you to record data thanks to the Trend Capture function of the built-in memory as well as the possibility of transferring data and analysing the results achieved in the CMM-60 Multimeter Software. The device facilitates the diagnostics of potential problems covering the operation of electromechanical devices, industrial automation, motors and distribution of electricity. Precise indications, safety during work in industrial conditions, convenience of use and early detection of irregularities in the operation of machines and devices are the main benefits of having this device in your equipment.
-
TA-241 -
Tech-Aid Products
AZ-241 Adapter Panel is designed to meet manufacturer's requirements. This panel will allow by the book testing of the air data computer when interfaced with the main air data test fixture. The Scott-T transformer is optional or can be customer supplied. Without the Scott-T your API can read the altimeter resolver directly.
-
Lisun Electronics Inc.
EMI receiver system. It is a main test system for EMI (Electro Magnetic Interference) testing. The EMI-9KB is produced by the full closure structure and strong electro-conductibility material, which has high shielding effect. Due to the new technology for the EMI Test System, it solved the instrument self-EMI problem.
-
AVJoG -
CableJoG Ltd
*A two box solution to testing AV panel installations. *Each box only 150mm square.*Easy to use with only one button operation. *LCD display for test results. *All major AV connectors present, no need for extra adaptors. *6V battery or Mains use.
-
CX-IPX56B -
Shenzhen Chuangxin Instruments Co., Ltd.
Drop rain rain chamber Uses: This equipment is main to test the physical and other related properties of the products in the environment of simulated rain, such as electronic and electrical products, lamps, electrical cabinets, electrical components, automobiles, motorcycles and their parts and components. After the test, through the test result to determine
-
Tabor Electronics Ltd.
Low power supply rails, a main part of the PXI, cPCI and PCI equipment, are a common cause for an inability to produce high voltage output. Tabor Electronics’ new amplifiers convert the supply rails to higher voltage suitable for signals up to 40Vp-p, thus solving thit problem.
-
CIS -
MeterTest Ltd.
The CIS current integrated source was designed to provide a stable alternating current source for the electricity meter test equipment, and in laboratories. The output current is isolated and independent from the mains voltage. Different CIS versions are available depending upon the values of output power and output current required.
-
Neutronics Manufacturing Co.
Sonel (Poland) Digital Insulation Resistance Tester, Range : 0-5kV/5TeraOhms, Battery-cum-Mains Operated, Voltage increment in Steps of 50v & 100V upto 5kV, Memory storage upto 11880 records, Data Transfer to PC/Laptop by USB Port, Free Software, PI & DAR Measurements.
-
IBEKO Power AB
CAT circuit breaker analyzers and timers are advanced standalone or a PC controlled instruments for circuit breaker maintenance. Typical application areas of CAT instruments are medium and high voltage substations at electric power generation, transmission, and factories of switchgear. Also, industrial environments and electric power distribution are suitable application areas for these circuit breaker testing instruments.DV Power CAT circuit breaker testing instruments are portable and lightweight. They are designed for performing mechanical operations intended for circuit breakers testing according to standards IEC 62271-100 and IEEE C37.09.These instruments measure:the timing of main contacts, pre-insertion resistor contacts, auxiliary contacts operations,coil currents,motion parameters,voltage recording,main circuit resistance,arcing contacts wipe,and any relevant analog signal.Motion transducer channels provide measuring a displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time, and average velocity. Even more, CAT circuit breaker analyzer optionally has a built-in micro-ohmmeter. Hence, it provides the main circuit resistance measurement and dynamic resistance measurement. Dynamic resistance measurement is an effective method for arcing contacts condition assessment.
-
1176 -
Draper Tools Ltd
Checks battery charge level and alternator output level. 880mm of insulated cable with test probe and earth (crocodile) clip. For 12V DC systems only. Display packed.Warning: For testing DC circuits on vehicles within the voltage range only. Not suitable for testing mains supply AC circuits.
-
CDN -
EMCTEST
The CDN M5 is intended to inject common mode disturbance signals to power supply of mains lines (unscreened) in the frequency range from 150KHz to 230MHz. A variety of calibration adapters and other accessories are available as an option. RF Standard connector: BNC type, AC socket 4mm safety bananas.