Filter Results By:

Products

Applications

Manufacturers

Magnet

Attract iron and are surrounded by a magnetic field.


Showing results: 181 - 195 of 207 items found.

  • Non-Contact Type Magneto-Electric Rotation Detector

    MP-9820 - Ono Sokki

    MP-9820 is a magneto-electric-rotation detector using an internal hall element, a permanent magnet, DC amplifier, and voltage regulator in its compact body. Using MP-9820 in combination with detection gear enables deriving stable rectangular waveform from ultra low speed all the way through high speed. (1 Hz to 100 kHz)MP-9820 finds wide range of applications and rotational measurement objects by using with TM-3100 series tachometer and FV-1500 FV converter.

  • Fixed Gas Detectors

    700 Series - Teledyne Gas & Flame Detection

    The sensor electronics are completely protected and immune to water ingress and corrosion. The sensor elements are all plug-in components and can easily be replaced in the field. Operator interface is non-intrusive via a small handheld magnet. Configuration and routine calibration is intuitive and menu driven with fully scripted instructions. Sensor status is displayed on a built-in alphanumeric LED display. The 700 Series intelligent sensor modules feature dual redundant outputs, a linear 4-20 milliamp analog signal and a Modbus RS-485 serial output.

  • Phase Sequence Indicators (Contact Type)

    865 PR - Standard Electric Works Co., Ltd

    ● The 865 PR is a detector with LEDs to show the de-    tection better visible than neon.         ● Three functions in one unit, including open phase,     phase sequence and 3 phase motor rotation.● Designed for checking a wider range of 3 phase         power source from 100V to 600V.● Indicates R.S.T LEDs which frequency range from 40Hz to 400Hz.● Wide range detection of motor frequency range from 2Hz to 400Hz.● Fixed magnets for convenient measurement.

  • Gaussmeter

    GM2 - Alpha Lab, Inc.

    The Model GM2 Measures the strength and polarity of magnetic field up to 30kG when using a standard probes, or 800 gauss (resolution 0.01 gauss) if an HS probe is used. Functions include DC, AC and peak hold along with a user-adjustable alarm which has three modes of operation. DC background field can be subtracted out either by pressing "Relative Zero" or by manually adjusting the offset. The meter includes battery, AC adapter analog output jack and calibration certificate. If a standard probe is used, resolution is 0.1 gauss up to 19,999.9 gauss, which is stronger than the field of any permanent magnet. This 5 digit display allows measurement of tiny difference in strong fields. Above 20kG the meter autoranges to a 30kG range.

  • Partial Discharge Detection and Localization System for Power Transformers

    AE-150™ - ndb Technologies Inc.

    The AE-150™ is designed to detect and localize Partial Discharge activity by correlating acoustic and electric sensors’ data. The AE-150™ has many acquisition modes, each used for detecting and locating Partial Discharge activity in a transformer. The AE-150™ unit is mounted on the transformer tank using its powerful magnets that also hold four acoustic sensors. Acquired data is sent to Mirador-Tx software where all advanced positioning functions are implemented. This cutting-edge software allows easy data interpretation, reporting and monitoring.

  • Automatic Hysteresis Graph Test System

    DX-4DMT - Dexing Magnet Tech. Co., Ltd

    X-4DMT automatic hysteresigraph system accords with the standard permanent magnet test system, GB3217-92, used to measure the major and minor hysteresis loops, demagnetization curves, recoil hysteresis loops and initial magnetization curves in different temperature of ferrite, AlNiCo, SmCo, NdFeB and quenched material, and gives the magnetic parameter, Br, Hcb, Hcj, (BH)max, Hk and so on, and could meet different requirements on test function, precision, power capability, reliability, efficiency, price, local environment from laboratory to enterprise's production line.

  • Magnetic Rotary 3 Click

    MikroElektronika D.O.O.

    Magnetic Rotary 3 Click is a compact add-on board for accurate magnet-position sensing. This board features the AS5147, an SPI-configurable high-resolution rotary position sensor for fast absolute angle measurement over a full 360-degree range from ams AG. The AS5147 position sensor suppresses the influence of any homogenous external stray magnetic field, equipped with a revolutionary integrated dynamic angle error compensation (DAEC™) with almost zero latency. It also comes with onboard headers reserved for incremental and commutation signals of their respective A/B/I and U/V/W signals alongside embedded self-diagnostics, including magnetic field strength too high, magnetic field strength too low or lost magnet, and other related diagnostic features. This Click board™ has been designed to support BLDC motor commutation for the most challenging automotive applications.

  • Magneto-Electric Rotation Detector

    MP-981/AP-981 - Ono Sokki

    The MP-981 is a magneto-type detector using a hall element which is suitable for revolution (r/min) measurement from low speed to high speed.Magneto-type detectors use an internal hall element, a permanent magnet, DC amplifier, and voltage regulator and respond to flux, so that a rectangular wave form is derivable from much lower speed all the way though high speed.In addition, a signal indicator is provided in spite of the detector's compact design, making verification of operation and mounting position possible.Meanwhile, the AP-981 is the water and acid proof type, which conforms to Class ' of JIS C0920.

  • Phase Indicators

    Kyoritsu Electrical Instruments Works, Ltd.

    New technology permits safe testing, without the need of direct contact between probes and live wires. The insulated crocodile clips can clip insulated cables from 2.4 to 30mm. Phase rotation is indicated by the rotary illumination of LEDs and logical audible tones. The instrument can be fixed to a metal panel via the magnet on the back side. Wide measuring range for 3 phase installations from 70V to 1000V AC. Super brightness function permits clear LED''''s indication also in sunshine. Complies with IEC 61010-1 CAT IV 600V and CAT III 1000V.

  • 8 Function True RMS Multimeter

    Extech EX360 - Extech Instruments Corporation

    The EX360 is a Compact Electrical True RMS MultiMeter with a Built in Non Contact Voltage Detector. Featuring highly accurate True RMS measurements, LoZ for the prevention of false readings caused by ghost voltages, .5% basic accuracy, a 1000V AC/DC volt range, resistance up to 40MΩ, continuity beeper with visual alert, smart data hold, peak hold, auto power off with disable, relative mode for capacitance zero and offset adjustment. Additionally, the EX360 excels in frequency and capacitance measurement. Complete with test leads, 9V battery, holster with tilt stand and built-in magnet.

  • Fluxmeters

    Ferrites India

    Flux meter has been the established standard for the measurement of magnetic flux density for determining total flux in a magnet or magnetic assembly. Its use was curtailed except in a few specialized areas because of many factors such as the difficulty in setting up light beam flux meter or ballistic galvanometers, limitations on the ohmic resistance of search coils, the requirement of some degree of operator skill in reading the flux meter etc. The development of the integrating type Digital Flux meter has virtually cancelled the hitherto negative aspects of fluxmeterology and has found a broad niche for many magnetic measurement applications.

  • Angle Position On-Axis

    ams AG

    The magnetic rotary position sensor product family detects the absolute angular orientation of an on-axis two-pole magnet rotating over the center of the IC. The absolute angular position can be provided in various formats, including PWM, ABI and UVW, or directly read through the host interface. According to the application’s requirements, resolutions from 8-bit up to 14-bit are available. This technology can be employed in high-accuracy angle position detection, high-speed rotation systems and brushless DC motor control. Any rotary magnetic position sensor can replace either absolute or incremental optical sensors, other magnetic and inductive technologies, potentiometers or magnetic switches.

  • Vector/Magnitude Gaussmeter

    VGM - Alpha Lab, Inc.

    The Vector Gaussmeter displays the true magnitude of the field at any location as well as the X, Y, Z components of up to 800 gauss. Also separately displays peak values of X, Y, Z, and magnitude. There is a sound alarm that determines the locations where the field magnitude exceeds user-set threshold. Because magnitude is measured, the orientation of the sensor (E-W, N-S, and up-down) is not important; this is unlike a 1-axis gaussmeter. With the VGM the user can set the alarm to 15 gauss (for example) and it will sound (simultaneous with a red light) whenever the field exceeds 15 gauss for at least 5 milliseconds. Using the meter this way, it is easy to make a map of the 15 gauss line (or for whatever threshold is set) around a strong magnet. When using the alarm, of a steel part can be rapidly scanned to show if any areas exceed the set threshold. Then the "peak hold" function can be interrogated, showing the peak values of X, Y, Z (including polarity) and magnitude that occurred during the scan. Peak hold also has a 5 millisecond response time.

  • Zero Gauss Chamber

    ZGC - Alpha Lab, Inc.

    The model ZGC zero gauss chamber reduces the environmental magnetic field (Earth field) to near zero inside the chamber. Any gaussmeter probe which is less than 9.4 mm or 0.370" diameter can be placed inside. The meter is then "zeroed", which means that it will read zero whenever the probe is subsequently placed in zero field. By using a zero gauss chamber, any offset error is therefore eliminated. The model ZGC is unique in that it contains a degausser (demagnetizer). This is situated between the inner and outer mu-metal shields. When the degauss button is pressed, any accidental magnetization of the chamber, no matter how strong, is erased. Accidental magnetization is a major problem with most zero gauss chambers and it has limited their use. If a magnet comes too close, the chamber will become "permanently" magnetized and will have an internal field that is typically 0.2 to 0.5 gauss. The chamber must then be degaussed because the Earth field is also around 0.5 gauss, so a magnetized zero gauss chamber will not significantly reduce the field.

  • Magnetic Field Meter

    Tenmars Electronics Co., Ltd.

    1. Can measure DC and AC(40-500Hz) magnetic field.2. DC N/S polarity of magnetic field display.3. After machine component are processed, remain the magnetism to measurement.4. Magnetic application products, the intensity of magnetic field measurement.5. After processing the stress with stainless steel material, remain the measurement of the magnetism6. Magnetic force measurement of the magnetisable material.7. Various steel products brought magnetic measurement naturally.8. Electrical home appliances products, the magnetic field intensity measurement of the motor9. Magnetic field intensity measurement of the permanent magnet.10. Exceed the leakage magnetic field of conducting the magnetite to measure

Get Help