Showing results: 901 - 915 of 2327 items found.
-
NEO TELE-TRONIX PVT. LTD
The meter is used for testing cables under load condition. Available in various specifications and models, it is of great use in power generation sector.
-
Shimadzu Corp.
The servo actuator system applies static test force loads on structures at high precision to obtain their mechanical characteristics on an experimental basis.
-
Isotek
IsoTek’s unique Direct Coupled Design system offers extremely low impedance high current clean power for the hardest of loads.
-
SY081 -
Synectic Electronics
The SY081 Strain Gauge Indicator is a hi-resolution 24bit load indicator. The meter can measure scaled loads on a variety of tranducers. It can display weight, pressure and also torque and offers 10 channels, and 7 point linearisation. The meter is easy to calibrate by applying a known load, or you can enter the mV/V of the load cell from a calibration certificate. The SY081 has a shunt calibration option and a fine adjustment facility to correct for drift over time in transducers.
-
Teledyne Marine Impulse-PDM
When designing an underwater cable harness, there are some factors which need to be considered, and we have produced the following list as a guide for customer information:Component considerations:- Electrical requirements- Mechanical considerations- Quality requirements- Reliability- Design redundancy (contact count)- Connector selection (type and form)- Locking requirements- Backpotting requirements- Waterblocking in moldings- Cable specification- Cable jacket material and compatibility with elastomers- Abrasion resistance- Stiffness profile at termination- Connector format (straight or right angle)- Molding format (straight or at an angle)- Clearance allowance for molding and cable routing- Elastomer compatibility (eg oil filled units)- Metalwork selection re: corrosion and cathodic delamination- Surface finish for metalwork as appropriateOperational considerations:- Operating depth profile (not just max. depth)- Tensile loads- Torsional loads- Bending loads- Bend control requirements (to limit bending at termination)- Deployment and recovery loads- Dynamic loading-Flow turbulence effects.
-
Part No. LPBD100 -
Teledyne Defense Electronics Relays & Coax Switch
The LPBD100 is a dual-output 100 Vdc plastic relay. The relay output-switch contacts are normally closed and will conduct the load current until a voltage is applied to the relay input. With 4 volts or more at the relay input, the output-switch contacts open and the relay no longer conducts. The LPBD100 assembly contains two independent, completely isolated relays.MSL 6 Available options include:LPBD100 0.25Adc, 100Vdc Load; 4-7Vdc Control;
-
40-160-001 -
Pickering Interfaces Ltd.
The 40-160 module has a choice of 10 x SPST, 20 x SPST or 10 x DPST Power Relays, suitable for switching inductive/capacitive loads up to 10A at 250Vac.Power Relay Modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids.It is suitable for applications requiring switching of either mains voltage or DC current.
-
40-160-002 -
Pickering Interfaces Ltd.
The 40-160 module has a choice of 10 x SPST, 20 x SPST or 10 x DPST Power Relays, suitable for switching inductive/capacitive loads up to 10A at 250Vac.Power Relay Modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids.It is suitable for applications requiring switching of either mains voltage or DC current.
-
Taylor Dynamometer, Inc.
Each of the four models available offers excellent dynamic response due to the low moment of inertia and high pulse torque. Advanced control capabilities allow for motoring or absorbing to provide variable road load simulations and simulated terrain. Also equipped with a positioning encoder, our AC Chassis Dynamometers allow a top recommended speed of 90 mph (145 kph) at full load.
-
40-660-001 -
Pickering Interfaces Ltd.
Model 40-660 is a 10-Channel Power Multiplexer, suitable for switching inductive/capacitive loads up to 10A at 250VAC. It is available with a choice of 1-pole (10A) or 2-pole (8A versions). Model 40-665 is a higher density 18 Channel Power Multiplexer with the same specification as the 40-660. Power Multiplexer Modules are intended for switching heavy AC or DC loads or for slave switching large external relays, contactors and solenoids.
-
National Technical Systems
Compression testing is a very common testing method that is used to establish the compressive force or crush resistance of a material and the ability of the material to recover after a specified compressive force is applied and even held over a defined period of time. Compression tests are used to determine the material behavior under a load. The maximum stress a material can sustain over a period under a load (constant or progressive) is determined.
-
40-665-001 -
Pickering Interfaces Ltd.
Model 40-660 is a 10-Channel Power Multiplexer, suitable for switching inductive/capacitive loads up to 10A at 250VAC. It is available with a choice of 1-pole (10A) or 2-pole (8A versions). Model 40-665 is a higher density 18 Channel Power Multiplexer with the same specification as the 40-660. Power Multiplexer Modules are intended for switching heavy AC or DC loads or for slave switching large external relays, contactors and solenoids.
-
HBM, Inc
HBM force sensors and force transducers measure static and dynamic tensile and compressive loads - with virtually no displacement. Your force load cell can be supplied in the most varied of designs and classes of accuracy. Typical force measurement application areas include bench testing, e.g. force measurement to check material quality and automation technology, e.g. for monitoring quality during reshaping or bonding operations.
-
HG-2-1000 -
Shenzhen Chuangxin Instruments Co., Ltd.
Digital push and pull force gauge is a universal portable force device, testing push and pull load. It is small, light, easy to take, multi-function, high precision. Applicable for all products doing push and pull load test, insert and pull out force test, destroy test, etc. It also can be combined with the machine and clamp to make up a small tester for different purposes.
-
SC Series -
Entes Elektronik
SC Series Thyristor Switches are used in systems which contain fastswitching inductive loads. The capacitors, which will be used to provide capacitive power to the system, can be switched on and off with a switching time shorter than 20 ms (1 period) by using SC Series Static Contactors, thereby providing a more effective compensation for fast-switching loads such as tack welding machines, cranes and arc furnaces.