Showing results: 391 - 405 of 2327 items found.
-
EE-120A-3 + EE-500V-3 -
EMSYST Ltd
The Phantom Load is able to generate three-phase voltages and currents with unprecedented stability and measurement accuracy. The amplitude and phase-shift of each current and voltage is individually adjustable. The generated values of voltage, current, power, power factor, phase shift, THD and frequency are indicated on the LCD display.
-
17-77 -
Testing Machines, Inc.
The model 17-77 Top Load Compression Tester meets international standards and corporate testing methods for compression strength requirements for a variety of materials and products. A new enhanced microprocessor design with servo motor provides precision force and position control for repeatable instrument performance.
-
500 Series -
HITEC Sensor Solutions Inc.
The Miniature S-Beam Load Cell is a bi-directional Aluminium strain gage based transducer with high performance and builtin temperature compensation. This design provides better than ±0.1% (full scale) non-linearity and includes overload protection in both tension and compression directions. Options include IEEE1451.4 TEDS capability.
-
S94572B -
Keysight Technologies
The software enables power amplifier distortion measurements under varying load conditions that are controlled across the entire modulation bandwidth. When design verification and robustness evaluation require testing the device away from the optimum loading condition, this application provides powerful insight into device performance and degradation.
-
REOLOAD 310 -
REO Ltd.
A three phase load bank rated for 48kW, with fan cooling. The front panel layout includes a switch panel for configuring the separate resistor modules to give the required resistance and current range. There are also digital panel meters for displaying the phase voltages and currents. An interface for PLC control is also provided.
-
ITC75300 -
Integrated Technology Corp.
The ITC75300 is a 400 amp version of the ITC75100 which performs ruggedness testing of power MOSFET’s, IGBT’s and diodes that conforms to MIL-STD-750 method 3470 by stressing them to controlled energy levels, accomplished by the devices driving an unclamped inductive load. Improved Test Specifications allow complete control of test parameters.
-
IT8700 Series -
I-TECH Electronic Co., Ltd
IT8700 series programmable DC electronic load adopts removable modules design, supports up to 16 channels with mainframe extension transient mode up to 25 kHz, which improves your test efficiency, with high resolution and accuracy. Users can freely choose in the 8 load modules according to the number of channels and power requirements, controlled by mainframe control panel, or controlled by host computer software via built-in LAN / RS232 /USB / GPIB interface. IT8700 is with adjustable slope, list function, automatic test and other functions, and can be applied to multiple or single output AC/ DC, DC / DC power converters, chargers and other power supply electronic components performance test, also can be used in ATE test system, solar cells, LED, communications testing, aerospace and other fields.
-
Creative Design Engineering, Inc.
*Type: Table Top*Wafer load: Manual *Wafer size: 2" to 8", 152mm x 152mm*Mini Environment: N/A*Probe Changer: N/A*Aligner: N/A*Size: 12" x 19" x 10"*Range: 1m/ to 10M/*Accuracy: 0.5%*Repeatability: 0.02% *Static Repeatability: 0.1% dynamic
-
63000 -
Chroma Systems Solutions, Inc.
The 63000 series programmable DC electronic loads are reliable, precision instruments primarily designed to test switching power supplies, A/D power supplies, power electronic components, adapters, 3C batteries and chargers. Its maximum 350W rated power makes it suitable for testing numerous types of lower power devices.
-
TBOH02 -
TekBox Singapore Pte. Ltd.
The TBOH02 is a self powered, precision active load. It does not need a separate supply voltage and operates as low as 2V. Its features include constant resistance and constant current mode. A 10 turn potentiometer with dial, a range switch and a precision reference enable accurate setting of current or resistance. Furthermore it can be controlled by an external voltage.
-
Ohm Loads Powertek Inc.
The DC SERIES load banks are designed for connection to DC Power Supplies , Aircraft Power Converters, Telecom Rectifiers, Batteries, Fuel Cells or any other DC power source. The DC SERIESis ideal for integration into racked test systems or bench - top testing. These standard models are easily configured for other voltage and current ratings.
-
XT9812 -
Xitron Technologies Inc.
Vitrek’s XiTRON XT9812 Programmable DC Electronic Load is designed for LED Driver or DC Power Supply Applications. There is a special circuit that has been designed primarily for the LED driver. The design utilizes high performance semiconductors with high speed and high accuracy, and resolutions of 0.1 mV and 0.01 mA (the basic accuracy is 0.03%, the basic current rise speed is 2.5 A/us).
-
MightyWatt R3 -
kaktus circuits
The All-New MightyWatt revision 3 turns your Arduino Uno R3 or Arduino Zero (M0/M0 Pro) into an electronic load capable of dissipating 70 Watts in a very small form factor. Ideal for testing power supplies, batteries, solar cells, fuel cells or power amplifiers. MightyWatt R3 has a research-grade electronics and is aimed not only at hobbyists but also at professionals.
-
Ohm Loads Powertek Inc.
The AC SERIES load banks are designed for connection to any 120VAC or 240VAC single-phase, 120VAC/240VAC split voltage, or 120/208VAC three-phase WYE source. The AC SERIES is ideal for integration into racked test systems or benchtop testing of aircraft power inverters, small generator sets, UPS units and any other AC power source. These standard models are easily configured for other voltage and power ratings.
-
Junxy Energy
Traditional commissioning is a daunting task. Since formal system operation doesn’t begin until the system is commissioned, the commissioning team experiences intense pressure to complete the commissioning process quickly. Commissioning can involve high expense and requires staffs from different departmental disciplines to work together. For these reasons data center commissioning has almost uniquely been associated with large data centers (over 20,000 ft2 or 1,858 m2). In the recent past, many data center managers chose to roll the dice and perform little or no commissioning, relying only on start-up data to press ahead with launching the new data center. Given the reality of 24x7 operations, however, the alternative of exposure to major system failures and accompanying downtime is no longer an economically viable option. Commissioning has now become a business necessity. JUNXY series AC & DC rack mounted load banks can be used to introduce heat loads and to allow for simultaneous testing of both electrical and cooling systems.