Showing results: 661 - 675 of 838 items found.
-
Anton Paar GmbH
The TORC (Thermo-optical Oscillating Refraction Characterization) technique applies decades of know-how in optical instrumentation to thermal analysis in a novel and unique way. The technique requires minimal sample preparation at maximal tolerance for sample properties. You can determine the coefficient of thermal expansion, glass and phase transitions as well as polymerization for various samples: liquids, gels, pastes, and certain solids. For example: cured and uncured resins, adhesives, glues, etc. can easily be characterized. Both thermal and time-dependent processes can be monitored with minimal effort.
-
Nexera-e -
Shimadzu Corp.
The comprehensive 2D-LC methodology is a paradigm shift in liquid chromatography separation analysis. By combining two independent separation modes orthogonally in combination with a dual-loop/dual-valve alternate switching design, the highest possible peak capacity is achieved for LC chromatography separation. The new Nexera-e enables separation of even the most complex mixtures, providing a new level of knowledge and understanding of sample analytes. This is especially beneficial to the analysis of pharmaceutical impurities, proteolytic digests, food extracts, natural products and synthetic polymers.
-
ThreeParticle -
Becker 3D GmbH
Imagine 3D simulation would be easy to learn in a few days, entry barriers would be minimal, and applications almost limitless. This is already a reality with our revolutionary ThreeParticle ™ software . In a single simulation platform, the Discrete Element Method (DEM) can be used to simulate multi-physical systems with complex particle shapes, including multi-body dynamics (MBS), structural mechanics (FEM) and liquids (CFD) - without coupling to external packages. The simple and intuitive operation via a new user interface is the daily routine of simulation.
-
Extech 39240 -
Extech Instruments Corporation
Extech's 39240 is a waterproof stem thermometer. This stem thermometer is pocket sized with a digital display featuring 0.1° resolution and min/max recording. It measures temperature in frozen solids and liquids using the 2.75 in. (70 mm) stainless steel stem. Temperature measurements from -40 to 392°F (-40 to 200°C). MAX/MIN recall of high and low temperatures as well as Data Hold and Auto power Off features. Complete with one LR44 button battery and protective cover.
-
Agilent Technologies
Clinical microplate instrumentation provides high efficiency and performance for your clinical diagnostic workflows. From ELISA microplate readers and washers, to multifunctional liquid handling, multimode detection and automated microscopy, Agilent BioTek microplate instruments and software are designed for ease of use in setup and operation, while providing powerful analysis for quick, high-quality results. For even greater automation and higher throughput, microplate stackers, handlers and automated incubators transform a benchtop instrument into a walk away automated system.
-
Titan Enterprises Ltd
Titan’s oval gear (OG) range of flow meters operate on the basic positive displacement technique in that they take a discrete volume of liquid and pass it from the inlet to the outlet without loss or slippage. By nature these devices perform better at higher viscosities as the increasing fluid thickness reduces the leakage rate even further and extends the useful operating range to lower flow rates. The oval gear design allows these flowmeters to operate with a very low differential pressure, only millimetres of head in some cases.
-
MKS Instruments
The 1150C Vapor Source Mass Flow Controllers are pressure based measurement and control systems designed to meter and control vapor from low vapor pressure liquid and solid sources directly, without the need of a carrier gas using viscous flow through a choked orifice.
-
IC Software- MagIC Net -
Metrohm AG
MagIC Net is the software to control your Metrohm ion chromatograph and any modules for liquid handling, sample preparation, and automation connected. Intuitive operation, comprehensive system monitoring, and straightforward data management make MagIC Net, what it is: the preferred software for state-of-the art ion chromatography.
-
NEX CG II -
Applied Rigaku Technologies, Inc
NEX CG II, a powerful second-generation energy dispersive X-ray fluorescence (EDXRF) spectrometer, delivers rapid qualitative and quantitative determination of major and minor atomic elements in a wide variety of sample types — from oils and liquids to solids, metals, polymers, powders, pastes, coatings, and thin films.
-
ifm efector, inc.
*Pressure sensors for the detection of the system pressure in machinery and plant*Reliable monitoring of liquids and gases in pipes*Level and limit level monitoring on tanks and containers*Temperature sensors with high precision over the whole temperature measurement range*Devices with clearly visible LED display with alternating red-green indication
-
6013 -
AMETEK Drexelbrook
When selecting electrode sensors an important factor is to consider the specific characteristics of the liquid involved, the lengths required to obtain the desired control of levels, and the physical nature of the container.B/W Controls' line of electrodes has been developed to provide a practical, economical solution to almost every conceivable application and installation problem.Our electrode sensors are available in several varieties: solid rod (rigid), wire suspension, and standard gland plugs for high vibration applications. In addition, we offer custom options made per customer’s requirements.
-
DeltaTRAK
The Circular Temperature Chart Recorder’s external stainless steel probe allows you to measure the temperature of air, gas, liquids and semi-solids. The temperature chart recorder has a quartz clock movement, motorized chart advance and temperature accuracy of ±2°F (±1°C). The chart recorder comes in °F or °C models and runs on 120V or 220V AC, 50/60 Hz. A rear compartment houses 8 AA alkaline batteries, providing up to 48 hours of continuous recording in the event of a temporary power loss.
-
WIKA Alexander Wiegand SE & Co. KG
Float switches in (the process) industry are used for the point-based limit level detection of one or several levels. They work independently of foaming, conductivity, dielectric, pressure, vacuum, temperature, vapours, condensation, bubble formation, boiling effects and vibrations and are suitable for almost all liquid media. The switching operation is contact-free, free from wear and needs no supply voltage. The simple and proven functional principle of the float switch enables a very wide range of applications, from general industrial applications through to use in process plants or in the shipbuilding industry.
-
Cognex Corporation
The compact size of the Cognex In-Sight 2000 Mini expands the number of potential application for vision sensors and allows users to deploy vision sensors into more areas of their operation. In-Sight 2000 Mini models are 68% smaller by volume than standard In-Sight 2000 vision sensors, so they can fit into tight spaces. In-Sight 2000 Mini models also come standard with a liquid lens autofocus module, enabling faster job changeovers and the ability to change focus when the sensor is mounted in inaccessible places. Key features include:
-
AW Gear Meters
Lake Variable Area flow meters, often referred to as rotameters, measure flow rate of a liquid or gas by relating linear displacement of an internal “float” or sharp-edged orifice plate (Lake) to a corresponding flow rate. As flow rate increases, the orifice area that the flow moves through also increases – thus, the term “Variable Area.” Variable Area meters either allow flow through a peripheral orifice formed between a tapered wall and a float as in the traditional rotameter, or an annular orifice and an internal tapered metering pin in the Lake Monitor.