Showing results: 631 - 645 of 2176 items found.
-
-
-
Konica Minolta Sensing Americas, Inc
One of the most important tests in light measurement is the assessment of the total radiant power or luminous flux of light sources using integrating spheres. An integrating sphere’s inside surface is coated with a diffusely reflecting material which guarantees complete integration and homogenization of the emitted radiation. The integrated light is then measured at the detector port.
-
TY-9610 -
Wuxi Tianmu Instrument Technology Co., Ltd.
1, Optical SystemStructure: Pa type - RungeRaster: Radius of curvature: 750mmIncident slit width: 20 μ mExit slit: high-precision photolithography of the entire slit, according to different elements set up 30u-75u slit width.Detector: Photomultiplier tube ( PMT ) detector2, all digital excitation light source1. Fully digital intelligent composite light source DDD technology, which can automatically adjust the excitation parameters of light source according to the excitation characteristics of different materials, and truly realize full digital control. 2. Using the all-digital control mode, high-energy pre-combustion technology ( HEPS ), ultra-stable energy release stimulates the sample in an argon atmosphere. 3. The application of all-digital light source improves the measurement accuracy and similarity of the sample, improves the sample excitation speed, improves the spark stability, and makes the sample have better reproducibility. The maximum discharge current reaches 400A .
-
MIM -
Applied Scientific Instrumentation
ASI Modular Microscope components consist of tube lenses along with adapters and accessories that either are primarily used in the collimated light space or adapters that are to be used on the image side. Collimated light adapters use the 38mm diameter C60-RING system to connect components. Focus-side adapters attached to lens tubes with either a 30mm diameter coupling to the I.D. of the C60-TUBE, or with a 50mm coupling on the O.D. of the lens tube.
-
Materials Analysis Technology Inc.
Optical microscopy is used to display the surface morphology of samples by 2D intensity contrast due to deflection and reflection of visible light shined on areas of interest. Its resolution is about half of the incident wavelength, which is ~0.2 μm for visible light (wavelength of 400-700 nm). Such resolution limits the maximum magnification to X1000, and thus optical microscopy provides preliminary inspection of sample surface structure.
-
Apogee Instruments, Inc.
Apogee offers two types of quantum sensors. The Full-spectrum Quantum Sensors feature an improved detector that provides accurate measurements under all light sources, including LEDs, right out of the box. The Original Quantum Sensor is less expensive and great for measuring all light sources except certain LED colors, where post-measurement correction factors need to be applied to achieve accurate readings.
-
AccuMAX™ Series -
Spectronics Corp
Single detector with dual sensors measures both ultraviolet and visible light. Complies with ASTM specifications for MPI and FPI. Specially engineered for NDT applications. The AccuMAX XRP-3000 radiometer/photometer kit uses a dualwavelength UV-A/VIS sensor detector to measure both ultraviolet and visible light. Featuring automatic zeroing, integration and signal hold, the unit provides accurate readouts for UV, visible irradiance or radiance.
-
IRDL708 Series -
Amperis sl
The IRDL708 thermal imaging cameras are the new developed uncooled detector cameras, which have high resolution of 640x480 pixels, multi-rotary touch screen, normal and infrared image fusion, high brightness LED light, recording in H.264 format or normal format, images in JPEG format, light and sound alarm, voice and text annotations, network interface, built-in laser pointer, etc.
-
CoolOne -
HORIBA, Ltd.
For spectroscopy and microscopy experiments in the UV/Vis/NIR region of the spectrum, a photomultiplier tube (PMT) is the ideal detector for quantitative low light level measurements. A PMT is extremely sensitive, with very wide dynamic range so it can also measure high levels of light. PMT’s are also very fast so rapid changes in optical signals can be reliably monitored. As a practical matter, PMT’s are durable, long-lived, and economical.
-
Autolink AL619 -
Autel
The ABS/SRS + CAN OBDII DIAGNOSTIC TOOL AutoLink AL619 is built to help you determine why the Malfunction Indicator Light or the ABS / SRS warning light is on. Featuring ABS/SRS system diagnosis, TFT color display, built-in speaker, troubleshooter code tips, the tool is truly ultimate in power and affordability.Vehicle Coverage: please refer to Support & Updates > Knowledge Base > Vehicle Coverage for details.
-
HU-200TB-EH -
HORIBA, Ltd.
HU-200TB-EH is a laser-type turbidity meter that can measure turbidity of membrane filtered water, etc. with a resolution of 0.0001 degrees. A high-sensitivity turbidty meter with a minimum resolution of 0.0001 degrees at a measurement range of 0.0000 to 2.0000 degrees, which uses a long-lasting semiconductor laser as the light source and employs a transmission 90-degree scattering light method.This is best suited for sensitive measurement of turbidity on surface water.
-
Shimadzu Corp.
MALDI is the abbreviation for "Matrix Assisted Laser Desorption/Ionization." The sample for MALDI is uniformly mixed in a large quantity of matrix. The matrix absorbs the ultraviolet light (nitrogen laser light, wavelength 337 nm) and converts it to heat energy. A small part of the matrix (down to 100 nm from the top outer surface of the Analyte in the diagram) heats rapidly (in several nano seconds) and is vaporized, together with the sample.
-
28056 -
Parallax Inc.
The Lightware SF000/B is an ultra-small and light open-frame LIDAR laser rangefinder designed for size and weight constraint applications. Using a time-of-flight system to make very fast, accurate distance and speed measurements. Accuracy is not affected by the color or texture of the surface, nor the angle of incidence of the laser beam. The SF000 is virtually immune to background light, wind and noise, making it an ideal sensor to detect unexpected obstacles.
-
mks Ophir
Photodiode sensors have a high degree of linearity over a large range of light power levels: from fractions of a nanowatt to about 2 mW. Above that light level, corresponding to a current of about 1 mA, the sensor saturates and reads erroneously low. Therefore, most Ophir PD sensors have a built-in and removable attenuator allows measurement of up to 3 W without saturation.