Filter Results By:

Products

Applications

Manufacturers

Light

Visible spectrum of electromagnetic radiation from 400nm to 700nm.

See Also: Illumination, Lighting, Lightning, Lightwave, Daylight, Streetlight, Luminescence


Showing results: 2041 - 2055 of 2177 items found.

  • New Car Alternator Charging Tester

    Hangzhou Xun Anda Electrical Co., Ltd.

    1. Test application: 12V/6V batteries test and 12V Starting /Charging system test.2. Test battery type: regular liquid, AGM battery, GEL battery,VRLA battery3. CCA test range: 40~2000CCA (SAE).4. Voltage test range: 1.5-15V.5. Display SOH (state of health), SOC(state of charge).6. Test for multiple battery standards: SAE, DIN, EN, IEC, CA.7. Graphic LCD display with back light, LCD brightness adjustable.8. Multigle language operation: English, Chinese, Germany, French, Spanish. 9.internal resistance

  • Manual Vision Measuring Machine

    Sinowon Innovation Metrology Manufacture Ltd.

    High precision marble base and pillar ensures the high stability of vision measuring system; High precision toothless rod and fast moving locking device ensures repeatability error is less than 2um;High precise working stage with 0.5um optical linear scales ensures the accuracy is less than 2.5+L/200um;High definitive detent zoom lens and high resolution color camera ensures clear image without distortion;With programmable surface 4-ring 8-division LED Cold Illumination and contour LED telecentric illumination and built-in intelligent light adjustment, it can automatic control the brightness in the 4-ring 8-division.

  • Radiation Testers

    MRC ltd.

    The Ranger is a small, handheld, digital survey meter which offers excellent sensitivity to low levels of alpha, beta, gamma, and x-rays. It has built in efficiencies for common isotopes to calculate activity in Bq and DPM. It has a backlit display and a count light and abeeper that sounds with each count detected. Other features include selectable alert levels, an adjustable timer, and an optional wipe test plate. Internal memory and the free Observer USB Software allow you to download your data, set computer alarms, and calibrate your instrument! The Bluetooth and Observer BLE enables saving, sharing,and automation of surveys and RadResponder compatibility

  • Power Line Purpose Tester

    LX-221A+ - Shenzhen Lian Xin Technology Co., Ltd.

    ·Meet UL, VDE, CSA, SAA, T-MARK, KS. IRAM, CCC and other countries’ standards .·Used to test single – ends ,double –ends ,three-ends power supply cords.·Auto and continuous test in COND,Insulation Resistance ,Leakage Current, Line-to-line Hi-pot(inside HV), Leaking copper(outside HV), relative length,·Auto test the fine and detective goods, tested qualified ones can be be ejected by ejector pin and marked , automatic cutting defective products, and alarmed with voice prompt and light,·Provide with RS 232 interfaces, can communicate with PC, easy to upgrade,·Provide personalized customization according to different requirements.

  • Transmission Meters

    Shenzhen Linshang Technology Co., Ltd.

    As a leading window film transmission meter (window tint meter) manufacturer, Linshang Technology provides a variety of window film meters to measure transmission rate, rejection rate, SHGC for materials such as automotive film, thermal insulation film, architectural film, thermal insulation glass, etc. There are mainly portable solar film transmission meters LS160 series, LS162 series, LS163 series, desktop demonstration window tint meters LS101, LS180, LS181, L182, split transmission meters LS110A, LS110H. Whether you want to measure UV or IR rejection (940nm, 1400nm) or visible light transmittance, you can find a suitable window film meter here.

  • Digital Panel Meter

    VAW - Chuan Sheng Electronics Co., Ltd.

    VAW DC Multifunction Power Meter provide high accuracy measurement, display and communication of DC voltage, Current, Power, Energy(import / export), and Run Hour. They are also building in 4 Relay outputs, 1 Analogue output, 1 Pulse output , 2External Control Inputs and 1 RS485(Modbus RTU Mode) interface with versatile functions such as remote I/O, alarm and communication for DC power applications like as solar, wind power system or portable electronic device consumption testing.For the power saving, VAW has built in an innovation timer to switch down the light and power of LED. It makes sense to build the meter in a green power system.

  • LED Test Programmable DC Electronic Load

    IT8912E Series - I-TECH Electronic Co., Ltd

    IT8900 series high accuracy LED specific testing electronic loads can simulate the real output of LED lights with different characteristics.Their specific circuit can realize CR-LED mode, adjustable frequency, duty ratio PWM dimming output port (frequency: 20Hz-2KHz), I-pp/I-max measurement function can test current ripple and start up surge current of LED constant flow source. Voltage and current testing speed can reach 50KHz. IT8900 series provides CR-LED / CC / CV + CC / CR /CW and other working modes, built-in USB / RS232 / GPIB communication interface. Widely used in LED driver power dimming test.

  • LED Burn-In Test

    LXinstruments GmbH

    Burn-in system, based on LXI instrumentation, for concurrent testing of up to 80 DUTs in a climatic chamber. Devices to be tested include modern light emitting diodes and LED modules.The system consists of 2 control cabinets, each with 40 independent supply and measurement channels. Each channel can be configured individually via the operator software (current or voltage, including the relevant limit values). The software supports logging of current and voltage values for each DUT on all 80 channels with a sampling rate of <1s. Additionally, the software and system also support digital I/O channels, e. g. for controlling the climatic chamber. Inputs for connecting temperature sensors are also provided.

  • TOV Test System

    Shanghai Guantu Technology Co., Ltd.

    1. Safety protection: traffic light indication status, emergency stop and interlocking of the test product door2. Equipped with a computer, set the TOV power supply parameters through the software interface, and automatically test3. Equipped with alarm function, equipped with emergency brake switch, equipped with safety cover and door switch4. The computer interface displays real-time voltage and current data5. Automatically draw voltage and current waveforms, and can save the waveforms as BMP format pictures, which is convenient for editing experiment reports.6. Automatically record test time, test current, test voltage, etc., and save the recorded data to files7. Installation method: cabinet installation.

  • Relaying Current Transformer Analyser

    Eltel Industries

    *Measures Ratio, Excitation Characteristics, Polarity, Winding Resistance, Remanance, and Insulation Resistance of secondary winding. * Determines Composite Error. * Used to test un-mounted CTs or CTs that are mounted but isolated inside the power system equipment. * Conducts a whole series of tests automatically, thus speeding up the time to commission CTs and relaying systems. * Battery powered test set - light weight & fully portable. * Provides a graphical presentation of the CT excitation characteristics. * Determines the IEC 10/50 knee point and the point of maximum permeability, ANSI 45 degree Slope Point. * Detects shorted turns or insulation problems within the test CT, thus avoiding commissioning of faulty equipment.

  • Crank Angle Measurement System

    CP-5110B Detector/CA-6000B Amplifier - Ono Sokki

    CP / CA series are systems that detect the rotation angle of the engine crankshaft composed of CP-5110B Fiber Optic Crank Angle Detector, CA-6000B Crank Angle Amplifier and CP-5120 / 5130 Slit disk.CP-5110B Fiber Optic Crank Angle Detector makes it possible to detect the crank angle required for various engine performance tests such as combustion analysis with high accuracy and high response. As it has a light projecting and receiving method with an optical fiber, it provides outstanding vibration and noise resistance without a built-in electric circuit in the detector.CA-6000B Crank Angle Amplifier inputs a signal of crank angle detector and outputs a TTL level angle signal and a 1P / R pulse signal.

  • Duplex Double Test Insertion/Return Loss Test Station

    JW8302 - Shanghai Joinwit optoelectronic Tech,co.,Ltd

    JW8302 Duplex double test Insertion/Return Loss Test Station is a professional equipment to test CWDM device, multi-wavelength device, PLC, fiber optical patch cord and other passive optical devices. It is a new-generation precision optical instrument of JOINWIT who combined with so many years  experience in optical passive detection. It equipped with VFL or 850 light source , supporting threshold determination, automatic multi-wavelength detection, system integration, secondary development, upper computer solution, etc. Double LC interface or other different interfaces can be tested simultaneously which is convenient for testing and improves efficiency; The  VFL function could automatic on and off, no need to replace the connector.

  • Resistors

    Vishay Intertechnology, Inc.

    A passive two-terminal electrical component that implements electrical resistance as a circuit element. In electronic circuits, resistors are used to reduce current flow, adjust signal levels, to divide voltages, bias active elements, and terminate transmission lines, among other uses. High-power resistors that can dissipate many watts of electrical power as heat may be used as part of motor controls, in power distribution systems, or as test loads for generators. Fixed resistors have resistances that only change slightly with temperature, time or operating voltage. Variable resistors can be used to adjust circuit elements (such as a volume control or a lamp dimmer), or as sensing devices for heat, light, humidity, force, or chemical activity.

  • Radiation Detectors

    PCE Instruments

    A radiation detector is a device for measuring nuclear, electromagnetic or light radiation. A nuclear radiation detector identifies nuclear radiation by measuring the emission of ionizing radiation of alpha particles, beta particles and gamma rays. Also referred to as a geiger counter, a nuclear radiation detector consists of two main elements: the processing electronics and the geiger tube. The geiger tube is filled with low-pressure inert gas like helium, argon or neon. If radioactive radiation occurs, the inert gas is ionized. An anode within the geiger tube registers the quantity of ionized particles numerically correlating with the strength of the radioactive radiation. The radioactivity measurement is then displayed on the LCD screen of the geiger counter or nuclear radiation detector.

  • Wide Range Mini IR Thermometer

    Extech 42510A - Extech Instruments Corporation

    The 42510A Compact thermometer measures temperature from -58 to 1200°F (-50 to 650°C) with 0.1 degree resolution for readings up to 999.9 degrees. Adjustable High/Low set points with audible alarm alerts user when temperature exceeds the programmed set points. Adjustable emissivity for better accuracy on a variety of surfaces. Built-in laser pointer identifies target area. Backlighting illuminates display for taking measurements at night or in areas with low background light levels. 12:1 distance to target ratio. Data Hold and Min/Max, Over range indicator and Auto power off functions. Complete with 9V battery and pouch case.

Get Help