Showing results: 301 - 315 of 5968 items found.
-
NI
PXI DeviceNet Interface Modules have an onboard microprocessor and optically isolated physical layer to communicate with a DeviceNet network system as a master (scanner) or slave device. The modules ship with a high-level API that provides complete access to a DeviceNet network and features easy access to device data and streamlined explicit messaging. PXI DeviceNet Interface Modules are ideal for prototyping DeviceNet systems, PC-based control, embedded control systems, PC-based human machine interface (HMI), and DeviceNet network management utilities.
-
2210 -
The Eastern Specialty Company
TESCO’s new Desktop Test Interface Station (Catalog No. 2210) provides metering professionals with exceptional testing flexibility. The Test Interface Station is ergonomically designed for meter technicians working in a lab or a desktop, yet still rugged for field use. The Test Interface Station includes a zero insertion force (ZIF) meter socket, voltage selection, form selection, open/closed-link selection and bi-directional cabling to power a load box/test kit & connect test standard potentials. When combined with a test kit/test standard and powered via 120 VAC, the Test Interface Station creates a single position, stand-alone, meter accuracy testing device for various socket based meters (both mechanical & solid-state).
-
ICS Electronics
ICS's Serial to Analog Interfaces are designed to provide isolated analog and digital drive signals to control power supplies and other devices. Available in rack mountable Miniboxes™ and IN OEM board versions. All of ICS's Serial to Analog Interfaces are fully IEEE-488.2 compliant and HP-IB compatible.
-
ProDAQ 3000 Series -
Bustec Ltd.
The ProDAQ 3000 Series includes interfaces and controllers. ProDAQ VXIbus slot-0 interfaces make the connection from PC to VXIbus mainframe, providing access to VXIbus instruments. Users can build test and measurement systems by connecting instruments via standard computer interfaces to an existing computer. ProDAQ VXIbus slot-0 controllers provide a fully-customizable platform for embedded applications and support 2eVME and 2eSST transfers between controllers and instruments. Users can configure the ProDAQ 3000 Series of Controllers for use as a VXIbus processor module in non-slot-0 applications.
-
APCI-7300-3 -
TEAM SOLUTIONS, INC.
*PCI interface to the 32-bit data bus. *Asynchronous communication adapter, 1-port serial interface*1 socket for SI modules*Modular structure through SI modules*Configurable as: RS232, RS422, RS485, with or without isolation, or 20 mA Current Loop (active, passive) with isolation*Addressing through software
-
2200 -
The Eastern Specialty Company
TESCO’s new Field Test Interface Kit (Catalog No. 2200) provides metering professionals with exceptional testing flexibility. The Field Test Interface includes a zero insertion force (ZIF) meter socket, voltage and form selection, and connection points to link it with a TESCO Field Test Kit (Catalog No. 621, 630 or GA Series). When combined with a Field Test Kit and powered via inverter (commonly used on service trucks), the Field Test Interface will then power the Field Test Kit to create a single position, stand-alone, meter accuracy testing device for various socket based meters (both mechanical & solid-state). Power for the Field Test Interface can also be supplied by customer potential via TESCO Field Test Kit (no need for the inverter).
-
INTERFACE UTI -
Smartec bv
The Universal Transducer Interface (UTI) is a sensor-to-time signal converter, based on a period-modulated oscillator. Sensing elements can be directly connected to the UTI without the need for extra electronics to interface all different sensor type. The UTI can operate in 16 different modes. To obtain accurate results in any of the modes, one reference element of the same kind as the sensor is required.
-
P61 -
Validyne Engineering
The Validyne model P61 is a digital differential pressure transmitter designed for industrial pressure measurement applications. The on-board microprocessor provides high accuracy and improved stability in changing thermal environments. Communication and power via USB interface provides remote zero and span adjustment as well as digital pressure readings in engineering units. Drivers and software for the USB interface are included.
-
TestMatick Ltd.
Any user interface testing should be planned in details.It should include both manual and automated tests in order to be efficient.
-
PCCextend 125 HIB -
Sycard Technology
For those applications that require access to the CardBus PC Card interface that can't use a standard extender card, Sycard provides the PCCextend 125 HIB (Host Interface Board) which allows full access to all 68-signal and power pins on the PC Card host. Standard 0.1" headers allow the user to connect standard 34- pin ribbon cable to test or prototype hardware.
-
CF extend 180HIB -
Sycard Technology
For those applications that require access to the CompactFlash™ interface that can't use a standard extender card, Sycard provides the CF extend 180 HIB (Host Interface Board). The CF extend 180HIB allows full access to all 50-signal and power pins on the CompactFlash™ host. Standard 0.1" headers allow the user to connect standard 26-pin ribbon cables to test or prototype hardware.
-
Astronics Corporation
Connect your PC laptop, desktop and tablet computers to avionics databuses with pocket-sized Ballard USB interfaces. Ease of use, versatility and comprehensive databus functionality have made these rugged adapters the industry favorite for avionics test, analysis and simulation in the lab and in the field. Avionics labs routinely integrate Ballard interface cards and full-featured network appliances into their test setups for powerful and reliable databus connection.
-
NI
The PXI Ethernet Interface Module equips PXI systems with high-bandwidth Ethernet-based connectivity with up to 40 Gb/s data rates per port. Featuring compatibility with industry-standard network and automatic cable polarity detection, this module is ideal for high-performance data transfer and vision applications on the PXI platform. Additionally, the PXI Ethernet Interface Module has independent bandwidth to support up to four GigE Vision cameras without PoE.
-
Model 4865B -
ICS Electronics
* Adds a GPIB Interface to Instruments with a VXI-11 or Raw Socket Ethernet Interface.* Transparent data transfer handles ASCII and binary data.* Controllable with any IEEE-488.2 GPIB Controller* VXI-11 protocol supports control, abort and reverse channels.* Raw Socket protocol includes substitute command strings for GPIB Device Trigger, Device Clear and Interface Clear.* Auto-Find feature simplifies instrument linkage* Reuses existing test software with new Ethernet instruments.* Easy configuration with the 4865B's internal webserver.* Drop in replacement for the original Model 4865 with 2x to 5x speed increase.* 1 U high rack mount kit mounts one or two 4865Bs.* Includes universal 115/230 VAC Power Adapter.
-
C Series -
NI
C Series Vehicle Multiprotocol Interface Modules use hardware-selectable NI-XNET Transceiver Cables (TRC) to communicate High-Speed/Flexible Data‑Rate CAN, Low-Speed/Fault Tolerant CAN, and/or LIN. Using the NI-XNET driver, you can create applications that require real-time, high-speed manipulation of hundreds of CAN and/or LIN frames and signals. The NI-XNET device-driven DMA engine enables the onboard processor to move frames and signals between the interface and the user program without CPU interrupts, minimizing message latency and freeing host processor time. C Series Vehicle Multiprotocol Interface Modules work well in applications such as hardware-in-the-loop (HIL) simulation, rapid control prototyping, bus monitoring, and automation control.