Impedance Meters
measure the rate of voltage to current in a circuit at a specified frequency.
See Also: LCR Meters
- Applied Instruments, Inc.
product
Satellite Signal Level Meter
Super Buddy
Complete more installs faster and better using the Super Buddy satellite finder meter. Be "sure of your bird" with the positive ID feature or use the automatic scan to identify the unknown satellite. The Super Buddy's geo-sensitive "Field Guide" shows you just the birds visible to your install -- ALL of them, with their individual transponders. The Super Buddy even gives the elevation and azimuth for whichever satellite you select.
-
product
FC(Fuel Cell) Impedance Measurement System
KFM2150 System
The KFM2150 system is a fuel cell impedance measurement system configured with an FC impedance meter KFM2150 and an electronic load PLZ-4W series. Combination of KFM2150 and PLZ-4WA series (0V input type) supports impedance measurement for single cell of fuel cell.In addition to impedance measurement with AC impedance method, KFM2150 system provides IR measurement with current interrupt method.Application software enables test for each characteristic of fuel cell such as I-V characteristics, Constant Current characteristics, Current Interrupt method and Cole-Cole plot by the AC impedance method. Moreover, each test can be performed in a specified order.
-
product
Attenuators And Pulse Limiters
A bidirectional attenuator, i.e. the attenuation and power capability specification is valid for both directions. There is a large variety of applications for this attenuator: The measuring range of a spectrum analyzer can be increased. Any kind of meter can be protected against overload; it can be used to control the linearity of a meter reading. It can minimize measurement uncertainty caused by mismatched impedances. During an EMI receiver calibration an attenuator directly at the pulse generator output is inevitable.
-
product
Impedance Meter
ZM-100
Monacor International GmbH & Co. KG
Impedance meter for measuring the impedance (Z) of individual loudspeakers and loudspeaker lines.
-
product
LCR Meter
MCR8000 Series
MCR8000 Series is a LCR meter also called impedance analyzer with high precision and high quality. With new 32-bit core, as good as first class equipment. 7 inche true color TFT display. 20Hx-5MHz testing frequency, frequency point continuously adjustable.
-
product
LCR Meter
ET/QuadTech 1910/1920
The 1920 1 MHz LCR Meter is the most popular and designed to perform capacitance and impedance measurements on a variety of electronic components and materials over a frequency range from 20 Hz to 1 MHz. The1920 features programmable bias voltage from 1 mV to 2 V for biasing capacitors and other semiconductor devices during measurements.
-
product
ST2817B+ LCR Meter (50Hz to 100kHz, 10 points))
ST2817B+ LCR meter is a high-performance and cost-effective measuring instrument. It can automatically measure the inductance L, capacitance C, resistance value R, impedance modulus |Z|, quality factor Q and loss tangent value D and other component parameters. The instrument combines powerful functions, superior performance and simple operation, which can not only meet the needs of high-speed measurement on the production site, but also meet the needs of precision testing in quality inspection, measurement, scientific research and experiment departments.Applications: Passive component / Other component
-
product
Multifunction Electrical Installation Meter
AMPI-520
The AMPI-520 digital meter is designed to measure impedance in short-circuit loops without tripping the differential protection, it also measures the protection tare, earth resistance, continuity and phase sequence check.
-
product
Contact Voltmeter
CVM-780
The CVM-780 Contact VoltmeterTM combines the ease of use of a digital voltmeter with the high input impedance and low input capacitance of a true electrostatic voltmeter in a small, portable, battery operated package.Being a true electrostatic voltmeter, not a field meter means that it reads real voltage, without confusing it with electrostatic field strength, which can be distinctly different.
-
product
Dielectric Test Fixture
16451B
The 16451B is used to evaluate the dielectric constant of solid dielectric materials accurately, and complies with ASTM D150. The 16451B employs the parallel plate method, which sandwiches the material between two electrodes to form a capacitor. An LCR meter or an impedance analyzer is then used to measure the capacitance created from the fixture.
-
product
Capaciter Tester
KS-1600
Konstar Electric Industrial Co., Ltd
It is a dial instrument, and has the stable function and high reliability. It is driven by the battery. The instrument makes use of the indicator plate(102*79mm), thus displays clearly.This instrument can test the data of on-line capacitive resistance and on line impedance. It is an excellent instrument and an ideal tool for the people in labs, factory and household. When testing the mounted capacitor, it does net need to be completely out of power nor do the meter, and the meter can be testing continuously.
-
product
LCZ LCR Meter
SS1062A
LCZ LCR meters are a high-grade component test instrument upgraded from SS106X series, with 4 output impedance modes and measuring results compatible with other well-known LCR meters.
-
product
50Hz-100kHz LCR Meter
11022/11025
Chroma Systems Solutions, Inc.
0.1% basic accuracyTransformer test parameters (11025), Turns Ratio, DCR, Mutual Inductance0Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, 100kHz test frequencies21ms measurement time (≥100Hz)Agilent 4263B LCR Meter commands compatible4 different output resistance modes selectable for non-linear inductor and capacitor measuringHigh resolution in low impedance(0.01mΩ) and high accuracy 0.3% till 100mΩ rangeAdjustable DC bias current up to 200mA (constant 25Ω) (11025)1320 Bias Current S...show more -
product
Standard Air Capacitor Set, 1pF To 1000pF
16380A
The 16380A is a standard capacitor set consisting of four precision capacitors - 1pF (16381A), 10pF (16382A) 100pF (16383A), 1000pF (16384A). These capacitors are primarily used for performance tests of Keysight's 4-terminal pair LCR meters and impedance analyzers. Refer to the instrument's operation/service manual for the method of using these standards.
-
product
High Precision LCR Meter
MCR-5000 series
MCR5000 series is a multifunctional LCR precision meter used for testing various electronic components. Adopt 4.3-inch TFT LCD display, simple display, elegant layout. It is a high speed, wide band, 5 bit test resolution impedance measuring instrument with 40hz-200khz multipie frequency points and 0.1% accuracy, which can meet the requirements of component parameter detection in various occasions. Is a high - quality cost-effective tester.
-
product
100Hz-50kHz LCR Meter –
11021/11021-L
Chroma Systems Solutions, Inc.
The Chroma 11021/11021-L are the most cost-effective digital LCR Meters available, providing 100Hz, 120Hz, 1kHz, and 10kHz test frequencies for the 11021 and 1kHz, 10kHz, 40kHz, 50kHz test frequencies for the 11021-L. The standard RS232 interface, optional GPIB & Handler interfaces, high speed and stable measurement capabilities enable the Chroma 11021/11021-L for use in both component evaluation on the production line and fundamental impedance testing for bench-top applications.
-
product
Voltage Voltmeter
Voltstik
The Voltstik is a distribution voltage voltmeter designed for use on lines and in substations. This meter is employed onto a line by using a hot stick and universal chuck adapter. It is capable of measuring voltage phase to phase, and phase to ground. This high impedance instrument is an excellent choice for solving multiple problems associated with operating a medium voltage system. Its key applications are defined under three groups, safety confirmation of the voltage present, troubleshooting voltage problems, and phasing.
-
product
Vector Network Analyzers
RF VNA to a Broadband VNA, from a Premium VNA with the highest performance and no compromises to a Value VNA that offers solid performance with suitable measurement speeds for an R&D environment. No matter what your application, Anritsu has your VNA needs covered. Choose with confidence from the pioneers in VNA measurements, introducing the Wiltron 310 Impedance Meter in 1965, and introducing the first broadband VNA, spanning 40 MHz to 65 GHz, in 1999. The first to cover a span from 40 kHz to 125 GHz from a single coaxial connector.
-
product
LCR Meters
Sanwa Electric Instrument Co., Ltd
LCR meter is a type of electronic test equipment used to measure the inductance (L), capacitance (C), and resistance (R) of an electronic component. In the simpler versions of this instrument the impedance was measured internally and converted for display to the corresponding capacitance or inductance value.
-
product
Liquid Test Fixture
16452A
The 16452A provides accurate dielectric constant and impedance measurements of liquid materials. The 16452A employs the parallel plate method, which sandwiches the liquid material between two electrodes to form a capacitor. An LCR meter or an impedance analyzer is then used to measure the capacitance created from the fixure.
-
product
Transmission Measuring Set
Model 2031 / 2031A
- Compact Two in One Instrument with Level Oscillator & Level Meter- Selectable Spot Frequencies upto 4KHz- Digital dB Meter to Measure Level from-60dBm to +20dBm- Under / Over Range Indication- Built-in Rechargeable Battery- Lo-Batt Indication- Easy to Operate, Light in Weight & Portable- Selectable Spot Frequencies from 200Hz to 4000Hz- Extra Switchable Input & Output Impedance of 1120 ohms)
-
product
Open Termination, 4-Terminal Pair
42090A
The 42090A is an open termination and is primarily used for performance tests of Keysight's 4-terminal pair LCR meters and impedance analyzers. Refer to the instrument's operation/service manual for the method of using this standard.
-
product
Bench Meters
LCR Meters
The measuring objects of LCR Meters are the parameters of impedance components, including resistance R, inductance L, quality factor Q, capacitance C and loss factor D. The selection of digital bridge should consider the highest frequency, test accuracy, test speed and DCR test function of the tested device.
-
product
Earth Contact Resistance Tester
SCR ELEKTRONIKS have developed an equipment namely Earth Contact Resistance Tester to test the appliance. To ensure the safety of operator it is essential that the Earth path (connection) should offer minimum impedance to by pass short circuit Current to Earth. This is ensured by measuring Resistance of the Earth path by passing heavy Current say 25 A. The Earth Contact Resistance Tester essentially comprises of a Variable Current source with digital Ammeter to measure the Current supplied....show more -
product
LCZ LCR Meter
SS1061A
LCZ LCR meters are a high-grade component test instrument upgraded from SS106X series, with 4 output impedance modes and measuring results compatible with other well-known LCR meters.
-
product
Battery Impedance Meter
Operation is fast and simple. Just press the spring-loaded probes onto the two poles of the battery. After 1.5 seconds, the unit beeps (indicating good contact) and displays the battery voltage and either the number of siemens or milliohms, depending on the knob setting. The display continues to show these numbers after the probes are removed; it resets only when the probes are pressed onto the next battery. The impedance and voltage of any battery between 1.2 and 60 volts can be read. Because o...show more -
product
HIGH FREQUENCY DC BIAS
6565 SERIES
The 6565 HF DC Bias Unit is intended to be used with a Wayne Kerr 6500 analyzer, either the 6500B Precision Impedance Analyzer or the 6500P HF LCR Meter. Its function is to provide a source of DC bias current through the Device Under Test (DUT) while the analyzer is making AC measurements. Each 6565 unit can provide up to 10 A of DC current, and up to six 6565 units can be connected in parallel to supply a maximum 60 A. A digital ammeter on the front panel allows the user to see the dc bias current value and an indicator LED shows when the bias current is enabled.
-
product
High Current Short Circuit Loop Impedance Meter
AMZC-310S
Measurement of very small short-circuit loop impedances (with resolution of 0,1mΩ) using the current of 150A under 230V, maximum 280A under 440V, or measurement using the current of 23A under 230V, maximum 42A under 440V
-
product
Time Domain Reflectometer
TDR-420
TDR-420 is a hand held Time Domain Reflectometer designed to identify and locate faults in power, telecommunications and teletechnical cables. TDR-420 reflectometer allows to measure the length of the cable and determine the distance to damage or impedance variation in the range of 4 m to 6000 m in conductors with metal wires. The shortest measuring range of 7 meters and a dead zone of 0.6 meters allows to locate damages at a very close distance from the place where the device is connected.
-
product
CP500X, 500 MHz, ±60 V, 10X Attenuation, Single-Ended Passive Oscilloscope Probe
784253-01
The CP500X is a coaxial passive probe with fixed 10X attenuation for oscilloscopes that provide 1 MΩ input impedance. It is 1 meter in length. The CP500X attaches to BNC connections on both the signal input and instrument sides.
-
product
Multifunction Electrical Installations Meter
MPI-520
The MPI-520 multifunction meter is dedicated to perform diagnosis of electrical installation according to IEC 61557 standards. Digital meter MPI-520 is designed to measure impedance of a short cicuit loop also without triggering RCD, parameters of RCD, insulation resistance, earthing resistance, continuity and also for phase sequence testing. Furthermore to measure and logging of AC voltage and current, frequency and power.Wide range of standard accessories enable to perform all necessary measurements and safety test. Highly professional portable multifunction meter with memory of measured parameters.