Showing results: 76 - 90 of 858 items found.
-
19070 -
Chroma Systems Solutions, Inc.
The Sentry 19070 Hipot Tester series provides 2 models to choose from. The Sentry 19071 for AC Hipot testing; and the Sentry 19073, which combines both AC and DC Hipot with insulation resistance (IR) measurements into a single compact unit.
-
FLIR CM78 -
Teledyne FLIR
The FLIR CM78 is a True RMS industrial clamp meter for the electrician who works on high-powered equipment and temperature systems and needs a safe, capable combination tool. An integrated IR thermometer provides fast non-contact measurements on panels, conduits, and motors. FLIR Tools Mobile connects the FLIR CM78 to your compatible smartphones and tablets via Bluetooth®, and METERLiNK® technology wirelessly integrates electrical readings on your infrared image with FLIR thermal cameras.
-
FLIR GF77a -
Teledyne FLIR
The FLIR GF77a is the first uncooled autonomous leak detection camera from FLIR designed specifically to visualize methane gas. This affordable, fixed-camera solution provides upstream and midstream gas processors, producers, or operators the features they need to continuously monitor for potentially dangerous, invisible methane leaks. Small and lightweight, the FLIR GF77a is packed with FLIR-patented features, such as High Sensitivity Mode (HSM), for improved gas visualization. The GF77a can help oil and gas companies maintain valuable capital equipment, avoid product loss, meet emissions reduction metrics, and ensure safer work practices.
-
ST60 TO-18 -
Dexter Research Center, Inc.
A single-channel silicon-based thermopile provides lowest cost solutions in a small active area of 0.61mm x 0.61mm in a small TO-18 package. Time constant of 18ms with Nitrogen encapsulation gas. Delivers a very low Temperature Coefficient of Responsivity of -0.04%/C. This detector has a very short thermal shock response to ambient temperature change.
-
ST120 TO-5 -
Dexter Research Center, Inc.
A single-channel silicon-based thermopile provides lowest cost solutions in a small active area of 1.2mm x 1.2mm in a TO-5 package. Time constant of 25ms with Nitrogen encapsulation gas. Delivers a very low Temperature Coefficient of Responsivity of -0.04%/C. This detector has a very short thermal shock response to ambient temperature change.
-
S25 TO-5 -
Dexter Research Center, Inc.
A single-channel silicon-based thermopile that offers the smallest single element active area size at 0.25mm x 0.25mm in a TO-5 package. Delivers a fast 18ms time constant in Argon encapsulation gas and even faster with Neon gas at 9ms. Delivers a very low Temperature Coefficient of Responsivity of -0.04%/C.
-
M5 -
Dexter Research Center, Inc.
A thin film-based thermopile offering very low noise and a small 0.5mm diameter active area in a TO-5 package. This is one of the lowest noise thermopiles you can buy and provides a time constant 28ms time constant with Argon encapsulation gas.
-
DR34 Compensated -
Dexter Research Center, Inc.
A one-channel compensated thin-film thermopile in a TO-5 package. The active area and compensating element area are 3.16mm x 0.4mm each. Internal aperture minimizes channel-to-channel crosstalk and thus increasing sensitivity.
-
ST150 With Diffractive Lens -
Dexter Research Center, Inc.
A single-channel silicon-based thermopile with integrated diffractive lens and internal baffle that delivers a very low Temperature Coefficient of Responsivity of -0.04%/C with a high output voltage, 19.5 FOV and a quick time constant of 38ms. This Low-cost detector comes in a TO-5 package and has a very short thermal shock response to ambient temperature change.
-
M34 -
Dexter Research Center, Inc.
A thin-film thermopile in a TO-5 package with an active area of 3.16mm x 0.4mm that offers low noise output.
-
1SC Compensated -
Dexter Research Center, Inc.
A thin film-based single channel thermopile detector that offers thermal compensation to minimize effects of sudden ambient temperature change during the initial five seconds of change. The 1SC Compensated comes in a TO-5 package with a medium sized 1.0 x 1.0mm active area. Compensation is achieved through the integration of two additional half-sized thermopile elements. Internal aperture is standard and precisely defines active area for applications with FOV and/or spot size requirements.
-
1M -
Dexter Research Center, Inc.
A thin film-based thermopile with a 1.0mm diameter active area with good signal-to-noise ratio in a TO-5 package and a moderate time constant of 32ms with Argon encapsulation gas.
-
ST60 TO-5 -
Dexter Research Center, Inc.
A single-channel silicon-based thermopile provides lowest cost solutions in a small active area of 0.61mm x 0.61mm in a TO-5 package. Time constant of 18ms with Nitrogen encapsulation gas. Delivers a very low Temperature Coefficient of Responsivity of -0.04%/C. This detector has a very short thermal shock response to ambient temperature change.
-
ST60 LCC -
Dexter Research Center, Inc.
A single-channel silicon-based thermopile in a LCC package for surface mount assembly in a small active area of 0.61mm x 0.61mm. Time constant of 18ms with Nitrogen encapsulation gas. Delivers a very low Temperature Coefficient of Responsivity of -0.04%/C. This detector has a very short thermal shock response to ambient temperature chang
-
ST60 With Diffractive Lens -
Dexter Research Center, Inc.
A single-channel silicon-based thermopile with integrated diffractive lens and internal baffle that provides lowest cost solutions in a small active area of 0.61mm x 0.61mm in a TO-5 package. Time constant of 18ms with Nitrogen encapsulation gas and a 9 FOV. Delivers a very low Temperature Coefficient of Responsivity of -0.04%/C. This detector has a very short thermal shock response to ambient temperature change.