Filter Results By:

Products

Applications

Manufacturers

IR

electromagnetic radiation of wavelengths 700nm to 1mm which are longer than visible light but shorter than microwaves.

See Also: Infrared, Long-Wave InfraRed, Short-Wave InfraRed, NIR, FTIR, MWIR, LWIR


Showing results: 436 - 450 of 858 items found.

  • Gas Filter Correlation CO Analyzer

    Model T300 - Teledyne Advanced Pollution Instrumentation

    DescriptionFeaturesSpecificationsApplicationsDownloadsMaintenanceThe Model T300 measures low ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 14 meters. The energy loss through the sample cell is compared with the span reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing extreme sensitivity.

  • Hyperspectral Image Processing Software for THz Imaging Data

    ImageLab - Menlo Systems Gmbh

    ImageLab is a one-of-a-kind image processing tool developed by our partner EPINA for the analysis of data from various spectroscopic imaging techniques such as THz, optical, UV/VIS, IR, Raman, or mass spectrometry. Based on multivariate statistical methods it enables the user to analyze and classify acquired hyperspectral images, to merge them with maps of physical properties and to overlay them with conventional high-resolution color photos. Visualization of the image data and highlighting of analytical information round up the software package to an indispensable instrument for in-depth analysis of spectroscopic image data. ImageLab is now part of Menlo Systems’ imaging extension TERA Image. Ask us for possibilities to upgrade your THz imaging system with our unique software tool!

  • LightRanger 4 Click

    64206 - Parallax Inc.

    Parallax speeds the process of Propeller 2 development through our partnership with MikroE, who has created a family of 850+ Clicks for most I/O functions you may envision. For each of the Click boards stocked by Parallax, you will find a documented Spin 2 code example on our Propeller GitHub Object Exchange. Connect your Click boards to the Propeller 2 Evaluation Board or P2-EC Edge Breakout Breadboard using the #64008 P2 to MikroBus Click Adapter. Light Ranger 4 click is an accurate distance measurement Click board™ based on a ToF (Time of Flight) measurement principle. The FlightSense™ enabled VL53L1X rangefinder module from STMicroelectronics is a complete measurement stack on the chip. It is surprisingly easy to work with, as this highly integrated range finder module exposes only I2C interface, XSH and INT pins to the host controller. It features the invisible Class1 laser emitter, used to emit a narrow band of a harmless modulated light beam in the IR range (940 nm), physical infrared filters and optics to achieve the best ranging performance in various ambient lighting conditions with a range of cover window options. It can measure distances up to 4000mm, with up to 50 Hz ranging frequency.

  • Mid-Range Gas Filter Correlation CO2 Analyzer

    Model T360M - Teledyne Advanced Pollution Instrumentation

    The Model T360M CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 1.28 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range, making this instrument an ideal choice for CO2 reporting requirements associated with dilution CEMS.

  • Si1145 UV / Ambient Light / Proximity Sensor

    SEN-36002 - Playing With Fusion Inc

    SEN-36002 is a highly integrated carrier board designed for the Si1145 UV, Ambient Light and Proximity sensor IC from Silicon Labs. This sensor has 100mLUX resolution, and has a dynamic range of 1 LUX to 128 kLUX with IR correction. This means that whether your application is indoors in poor lighting conditions or outside in full sunlight, this sensor has you covered. In addition, we added a high power LED (150mA max, 20 degree) to take full advantage of the proximity sensing capability of this IC - something you won't see on most competitive carrier boards. Integration is easy with 4 x 4-40 sized mounting holes at the corners of the PCB and signal translation to handle interface voltages from 3V to 5V. The board is interfaced via an I2C interface and function pins have been broken out to a 0.1" pin header. The INT pin is also broken out for interrupt capability.

  • Electrical Testers

    Actron

    Actron is an industry leader in electrical testers for your car or home repair projects. Pick your choice of Actron’s digital multimeters to help pinpoint problem areas and determine which components need repair or replacement. Find shorted and open wiring with the help of our circuit testers. Troubleshoot fuel injectors, solenoids, and digital sensors with the Actron Automotive Logic Tester. Use Actron IR thermometers to check AC systems, brakes, catalytic converters, cylinder heads, and overheating electrical components. Use the Actron Videoscope to inspect hard to reach areas. Measure and set spark plug timing on older vehicles, tractors, lawn mowers and more using Actron timing lights. Find bad batteries and faulty charging systems with Actron Battery Load Testers. Our Remote Starter Switches allow one person to conduct tests while cranking or starting the engine.

  • High Voltage Switching Systems

    HXV Series - Cytec Corp.

    HXV products are high voltage systems intened for Hi-pot / IR or High voltage switching. They can be configured to drive from 32 to 128 switch points per chassis and can be configured as multiplexer (1xN) or Matrix (NxM) configurations. Stand HXV chassis are used for signals up to 5000 VAC rms ( 7400 V peak ) and can carry up to 5 amps of current. Custom systems can be built up to 25KV. Most of the modules used in these systems are 1xN multiplexers or 2x4 matrix modules that can be combined to form larger multiplexers or matrices. Connector options for standard HXV include 5 way banaba jacks / binding posts, Shrouded Banana Jacks or SHV ( High voltage BNC) if you need to use a high voltage cable with a grounded shield for safety applications. Control options include 10/100BaseT Ethernet LAN, RS232, GPIB or optional manual control. Standard HXV systems use high voltage reed relays. Custom HXV systems up to 25KV use application specific relays and connectors from a variety of vendors based on required specifications.

  • Multi Interface USB Adapter

    SUB-20 - Dimax

    SUB-20 is a versatile and efficient bridge device providing simple interconnect between PC (USB host) and different HW devices and systems via popular interfaces such as I2C, SPI, MDIO, RS232, RS485, SMBus, ModBus, IR and others. It is also a full "any to any" converter between all supported interfaces and I/O features. SUB-20 is a powerful I/O controller with 32 GPIO, 8 Analog Inputs, PWM Outputs, Edge DEtectors, LCD, Leds and push buttons.SUB-20 system includes SW package containing driver, API Library, GUI and Command Line based applications, C,C++,C#,VB.net, MATLAB, LabView sample code and documentation. SUB-20 can be used with PC 64/32 bit running Windows 2000/XP/Vista/Win7/Win8, MacOS, Unix/Linux and DOS.Working with SUB-20 does not require deep knowledge of low layers of the specific interface. All you need to do is to call right API function at the right place. And this is really very easy as API functions are well documented and "exampled". API set is relatively small but comprehensive.SUB-20 is equipped with status Leds, optional LCD and buttons. All this guarantee fast and comfortable development, field debugging and maintenance of applications including option of standalone operation.

  • Mid-Range Gas Filter Correlation Carbon Monoxide Analyzer​

    Model T300M - Teledyne Monitor Labs

    The Model T300M CO analyzer measures low to mid ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.The energy loss through the sample cell is compared with the span reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance from low to high range.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T300M comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software. ​​

  • Gas Filter Correlation Carbon Dioxide Analyzer

    Model T360 - Teledyne Monitor Labs

    The Model T360 CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.​The Model T360 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software​.​​​

  • Ultra-Low Range ​Gas Filter Correlation Carbon Monoxide Analyzer​

    Model T300U - Teledyne Monitor Labs

    The Model T300U Trace-level CO analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. Using IR absorption with a Gas Filter Correlation Wheel, the T300U is designed to allow ultra-sensitive CO measurements while still meeting the requirements for use as a US EPA compliance analyzer.The optical bench is enclosed in a temperature controlled oven, dramatically decreasing instrument noise and drift. The objective and field mirrors in the sample cell are gold plated to maximize signal to noise performance, while a temperature-controlled Nafion dryer on the inlet minimizes water interference caused by ambient humidity changes. Periodically, the T300U seamlessly corrects its baseline by routing the sample through a heated catalytic CO scrubber. This Auto Reference function corrects zero drift and reduces the effect of interferences.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T300U comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software. ​​

  • ​Mid-Range Gas Filter Correlation Carbon Dioxide Analyzer​

    Model T360M - Teledyne Monitor Labs

    The Model T360M CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 1.28 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range, making this instrument an ideal choice for CO2 reporting requirements associated with dilution CEMS.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T360M comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software. ​

  • ​Gas Filter Correlation Carbon Monoxide Analyzer​

    Model T300 - Teledyne Monitor Labs

    The Model T300 measures low ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 14 meters. The energy loss through the sample cell is compared with the span reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing extreme sensitivity. All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information, is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T300 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software​.​​

  • Carbon and Sulfur in Inorganic Materials by the Combustion Infrared Detection Technique

    744 Series - Leco Corp.

    LECO's 744 Series will redefine the way you determine carbon and sulfur in metals, ores and other inorganic materials. Using extensive customer feedback and innovative engineering, our latest instrumentation takes advantage of an immersive software platform that will increase usability and lower the cost-per-analysis.

  • Carbon and Sulfur in Inorganic Materials by the Combustion Infrared Detection Technique

    844 Series - Leco Corp.

    LECO combined our customers' feedback with innovative engineering to develop the CS844, an elemental analyzer designed for wide-range measurement of carbon and sulfur content of primary steels, ores, finished metals, ceramics, and other inorganic materials using the combustion technique. Our exclusive MS Windows®-based software, coupled with a boom-mounted touch interface, gives you complete access to instrument control, analysis settings, diagnostics, reporting, and more—without sacrificing valuable bench space.

Get Help