Showing results: 346 - 360 of 587 items found.
-
Model SST500X500 -
Gopal Electronics
Gopal Make single sheet tester SST is developed as per IEC 60404-3. It can be attached as probe to Ep400 Main unit and user can test specific total loss, specific apparent power, and r.m.s value of magnetic field strength as well as B/h curve in the software.
-
Acoustics for Communications
Audio, acoustics and electroacoustics testing and assistance for your product. * Audio Laboratory equipped with precision instruments from Bruel and Kjaer and others. * Emphasis is on product and component analysis not general acoustics. * TIA, ANSI, IEEE, ITU-T, ETSI, AES, UL, EN, IEC standards expertise.
-
Castle Group Ltd.
Noise Dosemeters are a type of sound meter designed to measure the levels of noise exposure to an individual over a period of time. All of our dosemeters are compliant to IEC 61252: 1993 / BS EN 61262:1997 and offer high quality and reliable personal noise monitoring solutions.
-
Com-Power Corporation
Com-Power's Current Injection Probes are used for RF conducted immunity testing per IEC 61000-4-6, CISPR 16-1-2, RTCA DO-160 and MIL-STD 461. Current injection Probes are to be used only when there is no commercially available CDN for the type of port(s) to be tested.
-
Guangdong Bell Experiment Equipment Co.,Ltd
DGBELL Thermal runaway test machine test the whole vehicle or the complete vehicle-borne ion battery system or the subsystem of vehicle-borne lithium-ion battery system, including a lithium ion battery and an electrically connected lithium ion battery. The applicable standard is UL 2580, IEC 62619.
-
Hilo Test
Hilo-Test manufactures power generators for surge current material and safety tests, in particular for the examination of diverting elements such as gas discharge tubes, varistors, SPDs, and components in which such protective elements are installed, according to according to the IEC / EN 61643-11. Below you will find the right solution.
-
NI
The C Series Functional Safety Module offers SIL 3 certification, according to IEC 61508. The safety logic solver resides inside the module, and you can program it with the included Functional Safety Editor software. The module contains built-in diagnostics that can monitor the status of the hardware and the integrity of the connections. You can use these modules to control critical safety functions in manufacturing assembly and test cells, large physical tests, condition monitoring applications, and process monitoring and control.
-
WIKA Alexander Wiegand SE & Co. KG
Thermocouples are temperature sensors that generate a voltage directly dependent on temperature. Compared to resistance thermometers, they are particularly suited for high temperatures up to 1,700 °C. Instrument designs from mineral-insulated sheathed cable are very resistant against extremely high vibration loads (depending on instrument model, sensor element and wetted materials). The accuracy classes 1 and 2 apply for thermocouples in accordance with IEC 60584 as well as the standard and special classes in accordance with ASTM E230.
-
PS270-1U -
Axiomtek Co., Ltd.
*Input Range: 90 ~ 264VAC Full Range*Output Voltage:**+5V, 18A (0.5A min)**+3.3V, 16A (0.5A min)**+12V1, 16A (1A min)**+12V2, 10A (1A min)**-12V, 0.8A**+5Vsb, 2.5A*MTBF(hours): At 25°C, 100,000h*Safety: TUV, CSA 22.2 NO.60950-1, IEC, UL, NEMKO, CE*Dimensions: 150 x 81.5 x 40.5 mm*Compatible with Axiomtek products: AX61120 / AX60530
-
SCR ELEKTRONIKS
The test system is a special version of the thermal test test system in the sense that the test jig is primarily designed to hold and connect multi pole MCBs for thermal verification so that each pole can be verified to trip within the IEC time band after the MCB has been riveted. This test ensures the trip verification of MCB so as to trip all the 4 poles at once when overload is detected in one single pole. In short, this is a verification-only bench.
-
SORAS LS -
PSE Instruments GmbH
In certification laboratories for photovoltaic modules, steady-state solar simulators are mostly used for stabilization / light soaking tests (MQT 19) and hot-spot endurance tests (MQT 09) according to IEC 61215 and IEC 61730. An initial stabilization is required for all PV modules that undergo a standard test procedure. For the hot-spot endurance test (MQT 09), it is important that the operator has easy access to the front and back site of the module. During the test, it is necessary to shade one cell after each other to take infrared pictures, which requires good visibility of the entire back side. Our swiveling module holding system enables easy access to the front and back side of the module.
-
TEM -
Mess- & Prüfsysteme GmbH
Partial discharge test system for laboratory or on-site measurement according to VDE 0434, IEC 60270 and EN50178 consisting of:*Partial discharge meter TMG*High-voltage coupling capacitors for decoupling of the PD pulses*Partial discharge calibrator TPK for determining the correction factor in the PD test circuit
-
Spark Family -
Larson Davis, Inc.
Spark® series dosimeters are compact, affordable and tamper-proof personal Noise Dosimeter that measures the following to applicable IEC and ANSI standards:*Noise Exposure: Multiple Dose; Projected Dose; Time Weighted Average; (all with 4 user selectable combinations of Exchange Rate, Threshold, Criterion Level and Criterion Time); Sound Exposure Level*Sound Levels:; Leq; Lmax; Lmin; Lpeak/Luwpk, SEL and more*Time and number of events above Ceiling Level (115 dB) and Peak Level (140dB)
-
PS400-XP2 -
Axiomtek Co., Ltd.
*Input Range: 90 ~ 264VAC Full Range*Output Voltage:**+5V, 20A (0.5A min)**+3.3V, 20A (0.3A min)**+12V1, 16A (1A min)**+12V2, 16A (1A min)**-12V, 0.5A**+5Vsb, 2.5A (1A min)*MTBF(hours): At 25°C, 100,000h*Safety: TUV, CS22.2 NO.60950-1, IEC, UL, NEMKO+CB, CE*Dimensions: 150 x 140 x 74 mm*Compatible with Axiomtek products: AX61221/AX61222/AX60501/AX60551/AX60552/AX61400/AX6145/AX6156/AX61492/AX61220
-
DE-5030 -
DER EE Electrical Instrument
Earth resistance range0~12 / 0~120 / 0~1200 Normal operation conditionsBattery voltagein range of "BATT.GOOD" Earth voltage measurementmax. AC 30V Output current3mA Response timewithin 1 sec. Insulation resistancemin. 100M / DC1000V between input terminals and case Withstand voltageAC3700V (50 / 60Hz) for 1 min. between input terminals and case Battery Check Battery1.5V x 4 Safety standardIEC 61010-1 CAT.III 300V IEC 61557, IEC61010-031