  • Leeb Hardness Tester

    THL210 - TMTeck Manufacturing Limited

    LCD display of 128×64 matrix with back-light, showing all functions and parameters. Converts to all common hardness scales (HV,HB,HRC,HRB,HRA,HS). English displaying and easy and convenient menu operation. Powerful PC Software available and USB 1.0 interface and USB with Protective Membrane. 7 types of Impact Device optional, which don't need to be recalibrated when changing them. Memory of 600 groups data(impact times:32~1). Lower limit setting and sound alarm. Material of “cast steel” is added; HB values can be read out directly when D/DC impact device is used to measure “cast steel” work piece. Printer be separated from main unit and copies of testing results can be printed as required. Normal battery AAA and big power store while USB connected and charging controlling circuit. Inbuilt function of Software Calibration.

  • Time Domain Reflectometer

    IRG 4000 - BAUR Prüf- und Messtechnik GmbH

    Cable fault location with the BAUR IRG 4000. The IRG 4000 time domain reflectometer is integrated in BAUR cable fault location systems and is used in combination with the system software for locating cable faults in single and three-phase cable systems. Thanks to the novel operational concept, cable faults can be located more rapidly and easily with IRG 4000. The high-performance industrial PC and improved measurement parameters allow for a precise cable fault location in all cable types. The well-proven and continuously enhanced methods are available for the cable fault location as well as the newly developed Conditioning SIM/MIM** method which makes it even more effective and quick to locate wet cable faults that are difficult to detect. The SIM/MIM technology with 20 reflection measurements per HV pulse allows for selecting the best reflection image for a very precise determination of the fault distance.* Easy operation thanks to intuitive operational concept*Maximum precision with high resolution and sampling rate*Precise fault location methods for every type of fault

  • High Voltage Surge Current Monitors

    HVSCM - Test Electronics

    Designed to be used with the Model HVST High Voltage Surge tester. The Surge Current Monitor allows simultaneously surge testing 20 units. The Surge Current Monitor monitors the current going through each unit under test at the time of the surge. If a unit under test breaks down or leaks, the Surge Current Monitor will identify the bad unit by lighting the corresponding LED. The most important features of the surge tester are its ability to test the entire winding insulation system. A high voltage surge generates turn to turn, coil to coil, and phase to phase voltage stress, as well as ground insulation stress. When used as a dielectric test, accurate voltage readings are essential. The HV Surge Tester monitors the voltage directly across the winding under test. In production testing we expect that most of the time the devices will pass. In the event that one should fail, the failed device would be removed and then all the parts would have ot undergo another surge test. Since most devices pass most of the time, simultaneous surge testing can be a real time saver.

  • Leeb Hardness Tester

    HT6561 - Rinch Industrial Co.,Limited

    Product synopsis1.1 Typical Applications* Die cavity of molds* Inspection of bearing and other mass produced parts on aproduction line* Failure analysis of pressure vessel, steam generator andother equipment* Inspection of installed machinery, permanent parts ofassembled systems and heavy work pieces.* Testing surface of a small hollow space* Material identification in the warehouse of metallic materials* Rapid testing in large range and multi-measuring areas forlarge-scale work piece1.2 Testing Features* Palm size for narrow space.* Test at any angle, even upside down.* Direct display of hardness scales HRB, HRC, HV, HB, HS,HL.* Large memory could store 250 groups including singlemeasured value, impact direction, material and hardnessscale etc.* User recalibration function allowed.* Can communicate with PC computer for statistics andprinting by the optional cable.* Manual or automatic shut down.* Low battery indication.1.3 Technical SpecificationsDisplay: 12.5mm LCD with back lightAccuracy: Display error ±0.8% at LD=900Measuring range: 200-900LConversion: HL-HRC-HRB-HB-HV-HSDMaterials: 9 different common materialsWith RS232C interfaceMemory: 250 data can be stored and re-readableImpact device: D Will handle the majority of hardness testingapplications. Weight: 75gPower supply: 2x1.5V AAA size batteryDimension: 146×65×36mmWeight: 130g (not including batteries)Working temperature: - 10℃~+50℃Storage temperature:- 30℃~+

  • 10KV High Voltage Digital Insulation Resistance Tester

    KM 6213AIN - Kusam Electrical Industries Limited

    • The KM 6213A IN is the KUSAM-MECO premium model of High Voltage Digital Insulation Resistance Testers.• The KM 6213A IN has new added features with a low consumption High Performance processor.• It displays results much faster and has more advanced features.• The KM 6213A IN has Automatic Polarization Index and Dielectric Absorption Ratio Calculations.• Results are displayed on the new High Contrast LCD. It’s mounting angle makes it more readable for all users, in different working conditions.• The user’s manual reflects the new features and added benefits of this instrument.• It has Auto-Off, Auto-Stop, EnerSave™ and is a non destructive tester.• Once you start the tester, it waits for your selection. You can go up and down in voltage to select the voltage at which you want to test the insulation. Once you have selected that voltage, you need to connect the test leads to the Insulation Tester to measure. Then it measures voltage to ensure there is no voltage present on the equipment under test. If there is a voltage present, it will warn you to disconnect the circuit before proceeding. If it’s free of any voltage, then you can proceed with the testing. This ensures that no damage is done to the Insulation Tester KM 6213AIN.• One of the new innovation on this tester is also the way the new unique calibration process works. It’s fully digital, has no moving parts and does not require expensive and complicated jigs or computers systems to be calibrated. It’s cheaper to maintain than any other Digital HV Insulation tester on the market today. The KM 6213AIN is supplied standard with our Premium test Leads Kit, the AL-50.

  • Circuit Breaker Analyzers & Timers

    CAT Advanced Series - IBEKO Power AB

    DV Power circuit breaker analyzer and timer utilizes the latest technological enhancements for safe and fast testing of circuit breakers. The sophisticated design ensures efficient and reliable operations in high-voltage substations and industrial environments.The CAT Advanced series are stand-alone or PC-controlled digital instruments for a circuit breaker testing. The timing channels record closing and an opening of the arcing, resistor, and auxiliary contacts. Also, the main contact channels can measure the resistance value of the pre-insertion resistors (if present in the circuit breaker).With CAT Advanced series instruments, it is possible to record graphs of open and close coil currents. Furthermore, it records displacements of the HV and MV circuit breaker moving parts. Test results can be saved via USB, PC or be printed via 112 mm (4.4 inches) thermal printer (optional accessory) in tabular and graphical form.A circuit breaker test consists of different operational modes and CAT Advanced series supports:Open (O)Close (C)Reclose (O-0,3s-C)Trip free (CO)O-0,3s-COOpen-Close (O-C)Close-Open (C-O)Open-Close-Open (O-C-O)First trip (O)Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by sensing a breaker’s contact position.The auxiliary inputs are used to monitor dry and wet auxiliary contacts. The six coil control analog channels measure and record coil currents simultaneously (OPEN and CLOSE), up to 35 A AC/DC.The additional six voltage analog channels have four selectable voltage ranges available (±1 V, ±5 V, ±60 V and ±300 V AC/DC).A built-in micro-ohmmeter generates up to 500A true DC ripple-free current with an automatically regulated test ramp that provides performing static and dynamic contact resistance measurement.Three transducer channels provide a measuring displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time and average velocity. Also, a user can connect either an analog or a digital transducer to these universal channels.

  • High Voltage, Continuity & Hipot, Cable & Wire Harness Test Systems

    CableEye HVX, HVX-21 - CAMI Research Inc. (CableEye®)

    Fast ● Simple ● Precise Advanced wiring analyzer scans for continuity (opens, shorts), miswires, resistance, capacitance, components (resistors, diodes, LEDs, capacitors) dielectric breakdown, insulation resistance, intermittent connections HVX (Item 829) 1500 Vdc, 1000 Vac HVX-21 (Item 829A) 2100 Vdc, 1200 Vac For diagnostic and Pass/Fail Testing — Permits expanded testing (compared to models in our low voltage product line) for insulation resistance (IRI) and dielectric breakdown (DWV). All CableEye testers are suitable for production, fault diagnosis, QC (Quality Control), assembly, and prototyping of standard or custom cables. Each combines test, fault location, design, documentation, labeling, and database storage in one instrument. Tests can be performed on long cables (with or without connectors) or no cables (e.g. connectors, backplanes, PCBs, components). Standard Features & Benefits:

    • USB certified, PC-based tester for a versatile, fast, robust system with long life-cycle.
    • Multilingual, dynamic, graphic-rich display (netlist & wiring schematic) provides clarity and speeds diagnostics.
    • 128 Test Points, expandable to 1024 providing flexibility as your product line changes.
    • User-selectable voltage to each connection group in the cable simplifies an otherwise complex process, accelerating testing.
    • Programmable Ramp Up, Ramp Down, Dwell Time (same as Test Time), Trip Current, and Trip Delay (same as Soak Time) adds versatility.
    • Current leakage detected during HV test phase provides a measure of insulation resistance up to 1 GΩ (HVX) and 5 GΩ (HVX-21) - any leakage current exceeding a preset limit reveals the presence of moisture, flux, or other contamination on exposed contacts.
    • Real-time screening for intermittent connections for pinpointing elusive faults and improving quality.
    • Automation scripting in a simple, intuitive language allowing non-programmers to reduce operator error by automating repetitive steps.
    • Pop-Up Work Instructions. choose the exact amount of detail, imagery, language and automation you need to ensure your work instructions and tests are carried out flawlessly.
    • Flexible tolerancing: optionally define as percentages or absolute terms, as well as asymmetrically (e.g. +0%/-10%) for improved yields.
    • Barcode-tracking & archival data-logging to achieve error-proof test process and improved traceability & productivity.
    • Print PASS/FAIL labels, test reports (with or without color wiring schematics/netlists) and log reports to satisfy ISO9000 reporting requirements.
    • Compatible with laptop and touchscreen PCs for fieldwork and rack/off-bench mounting.
    Includes: CB29 board set (Item 759) for bare wire connections; comprehensive PC software with Database of >200 standard cables; 2 yr Product Support Subscription comprising Warranty, free tech support, and free software upgrades. Select Add-On Options: Hardware: 128-point Expansion Modules (attach to base); 4-Wire Kelvin Resistance Measurement, 1 mΩ at 1 A; Advanced Measurements; External Measurement Instrument Port (e.g. 10 GΩ Isolation at 100 V); Remote Control Connector for Deadman Switch; Environmental Sensor Software: PinMap™ fixture editor, Connector Designer™ connector editor, or Autobuild™ guided assembly modules camiresearch.com |@CAMI_CableEye |+1.978.266.2655