Showing results: 31 - 45 of 337 items found.
-
B-1020-C -
ROSS ENGINEERING CORPORATION
These supply 120V or 240V AC continuous power for equipment that must operate while at a high voltage to ground or power source. For example, a fiber optic transmitter at the HV level for waveforms to be received and measured or recorded by grounded instrumentation might be powered by an isolation transformer secondary to primary either insulated by potting, oil or air. The low dielectric constant of air insulation provides lower capacitive coupling between the secondary and the primary or ground than would solid or oil insulation. The lower capacitance provides better isolation both at line frequency and especially at high frequency voltages such as lightning or switching transients.
-
SERIES S400 TYPE RX I O/ I OACP -
K&S Engineering and Scientific Ltd
The output is continuously variable from zero to 10 kV by means of the panel mounted regulator. An output trip is fitted which operates when the output exceeds 25 mA switches off the test set and operates a neon overload indicator. Primary protection is provided by two panel mounted fuses. The output is protected by the output trip and a magnetic/hydraulic circuit breaker.
-
RX30/4P -
K&S Engineering and Scientific Ltd
The output is continuously variable from zero to 10 kV by means of the panel mounted regulator. An output trip is fitted which operates when the output exceeds 25 mA switches off the test set and operates a neon overload indicator. Primary protection is provided by two panel mounted fuses. The output is protected by the output trip and a magnetic/hydraulic circuit breaker.
-
PMT10000 -
Power Measurement Technologies Inc.
High voltage, low dissipation factor, gas-filled Standard Capacitors for indoor use in a laboratory or production environment. A three terminal design configuration allows accurate measurements of capacitance and dissipation factor (tangent delta) with little or no effect from test lead or stray capacitance.
-
HTCT-201 / 350 -
Wuhan Huatian Electric Power Automation Co., Ltd.
Specially designed and manufactured for on-line measurement of primary current and secondary current of current transformers and transformers below 35kV, variable ratio, phase difference and polarity judgment.
-
-
KV Hipot Power Test Equipment Co.,Ltd
High Voltage testing is usually performed to qualify the device to operate safely during rated electrical conditions, a way to check the effectiveness of its insulation. The objective sought during the high voltage testing will determine the type and amount of voltage applied and the acceptable current flow.
-
B-1025-1 -
ROSS ENGINEERING CORPORATION
Design and manufacture of electronic and electromechanical devices and systems for our customers' special applications has been Ross Engineering Corporation's specialty for 44 years. Among these devices are our High Voltage Test Loads and Resistance/Capacitance Networks designed to simulate radar, communication, and television transmitter loads for testing up to 300kV DC or AC and 200kW. For example, one Test Load System required 4 separate simulated load networks to complete an 8kV, 14kV, 24/6kV, and 34kV high voltage testing system.
-
B-1013 -
ROSS ENGINEERING CORPORATION
*25kV, 50kV or 100kV Meter with integral line to ground Probe*Phasing or line to line with additional Probe*Optional 6ft or 9ft Collapsible Hotsticks*Voltage source for testing Voltmeters and Probes*Optional test point contamination indicating Megmeter®*High voltage cable clamps or hooks*Heavy duty carrying case
-
CBA-32P -
Zensol Automation Inc.
The CBA-32P is a multifunctional circuit breaker analyzer performing Motion, Timing and Dynamic Resistance Measurements, all in a single test.
-
-
The Motwane Manufacturing Company
For decades, Motwane Voltage Detector has been a standard for international quality and safety ratings. Voltage detectors are used to signal the presence of voltage in a conductor since they make visible what we normally can’t see. Its application lies mainly in safety reasons during research, or when a service operation is under way. Most of the time, the monitored conductors come from low impedance sources whose voltage and energies are considered life-threatening.
-
BI-3 -
Xi'an Multipower Technic Co.,LTD
Before the delivery, the high-voltage breaker should be run in to ensure every breaker with the good mechanical characteristics. The running-in switchgear shall be wiped off the burr of the component by the mutual force and frictions in the no-load operations to amend its shape and to achieve the best cooperation among the components. The concept of running-in has been the mutual understanding of the international leading switchgear manufacturers.
-
YDQW-50KVA/250KV -
Wuhan Sangao Electrical Test Installations Limit Co.
SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test, and for testing all GIS switchgears and GIS components such as insulators, insulating tension pole, GIS voltage transformer and so on, the PD test can be performed under the general environment because of the merits of encapsulation, the PD level of our equipment can be lee than 3pC, and it can be added a HV bushing to perform the withstand voltage test at the same time.Small and compact dimensions resulting in minimum space requirements. Light-wight components. Rugged construction to withstand long transportation stresses. Direct flanging to the test object. High safety for tester because of encapsulation of all HV parts. Large range of application in conjunction with HV bushing for withstand voltage test. Built-in HV measuring capacitor and coupling capacitor. Built-in HV disconnecting switch to separate multipath test object connector to ensure the safety of HV testing.
-
ORTEC
ORTEC offers two types of power supplies for use with NIM instrumentation: power supplies that provide operating voltages for a detector (more properly called detector bias supplies or “HV” supplies) and power supplies that provide the necessary operating voltages for NIM Modular electronic instruments in the form of a NIM “Bin” with associated power supply.