Showing results: 1 - 15 of 37 items found.
-
CP RC -
OMICRON electronics
For HV testing OMICRON’s CPC 100 + CP RC are directly connected to the voltage transformer of the GIS, forming a resonance circuit. This reinforced “Power VT” is an integrated part of the GIS. So the need for draining and refilling any SF6 gas is eliminated. Acting as both the measuring and controlling device, the CPC 100 injects the required energy.
-
GIT GIS -
HV Hipot Electric Co.,Ltd.
GIT GIS High Voltage Test Sets integrate the high voltage boosting, high voltage measurement, high voltage transformer,high voltage coupling capacitors and all components in a sealed space.High voltage generated with two modes:using reactor inductance and test object capacitance to realize voltage resonance test, to obtain a high voltage, high current from test object.The other one is to obtain required high voltage directly from high voltage transformer.
-
JHPD-20 -
Xiamen Jiahua Electrical Technology Co.,Ltd
JHPD-20 detects and diagnoses the partial discharge inside the gas insulated switchgear (GIS). By using the UHF sensor attached on the surface of GIS or inside the GIS and the noise sensor which excludes the disturbance signal, the detector analyzes the GIS operation condition.
-
JHPD-10 -
Xiamen Jiahua Electrical Technology Co.,Ltd
JHPD-10 quickly and accurately detects various kinds of partial discharge signals that occur with insulation defects in GIS. Attached on the surface of GIS the detector collects the inside discharge signal of impure gas, suspension potential and solid insulation material. The diagnostic software analyzes the fault character and locates the fault to avoid electricity accident. The device is for daily patrol inspection with high efficiency and easy operation features. Designed with two UHF signal channels, one detects the partial discharge signal; another excludes the disturbance signal like corona discharge in the air and mobile phone communication.
-
VFT -
Dr. Strauss Messtechnik GmbH
The VFT-Measuring System TR-AS RC for VFT is special designed for high bandwitdth and allows measurements of very fast transients (VTF) in a frequency range from power frequency up to 100MHz directly with help of capacitive sensor, e.g PD-Sensors Installed in GAS-insulated Switchgear (GIS)
-
GTU-800KVA/220KV -
Wuhan Sangao Electrical Test Installations Limit Co.
SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test,and for testing all GIS switchgears and GIS components such as insulators,insulating tension pole,GIS voltage transformer and so on,the PD test can be performed under the general environment because of the merits of encapsulation ,the PD level of our equipment can be lee than 3pC,and it can be added a HV bushing to perform the withstand voltage test at the same time.
-
GTU-1200KVA/600KV -
Wuhan Sangao Electrical Test Installations Limit Co.
SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test,and for testing all GIS switchgears and GIS components such as insulators,insulating tension pole,GIS voltage transformer and so on,the PD test can be performed under the general environment because of the merits of encapsulation ,the PD level of our equipment can be lee than 3pC,and it can be added a HV bushing to perform the withstand voltage test at the same time.
-
GTU-800KVA/800KV -
Wuhan Sangao Electrical Test Installations Limit Co.
SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test,and for testing all GIS switchgears and GIS components such as insulators,insulating tension pole,GIS voltage transformer and so on,the PD test can be performed under the general environment because of the merits of encapsulation ,the PD level of our equipment can be lee than 3pC,and it can be added a HV bushing to perform the withstand voltage test at the same time.
-
YDSW Series -
Shanghai Jiuzhi Electric Co., Ltd.
SF6 insulated Test Transformers are especially designed for testing metal-clad switchgear (GIS) in the factory and in the field, and for testing the other substation equipment. It is also the portable and easy maintenance solution. The SF6 test transformers can be flanged directly to the GIS for testing which make the partial discharge test easy and quick. These systems are particularly suited for on-site tests of GIS after installation. In the factory, they are used to test sub-assemblies and components directly in the manufacturing line.
-
-
Hangzhou Xihu Electronic Institute
Cable PD detecting and positioning system, transformer PD detecting and positioning system, switchgear PD detecting and positioning system, GIS PD detecting and positioning systems.
-
Hangzhou Xihu Electronic Institute
Simulation device of cable PD faults, simulation device of switchgear PD faults, simulation device of GIS PD faults, simulation device of transformer PD faults.
-
Siradel sas
We put our combined expertise in 3D GIS data analysis, visualization and simulation at the service of the development of unique smart solutions to design sustainable urban transformation and connected infrastructure.
-
ROTOMAP GIS -
PASI srl
Software Geo&Soft / Rock Mechanics
-
YDQW-50KVA/250KV -
Wuhan Sangao Electrical Test Installations Limit Co.
SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test, and for testing all GIS switchgears and GIS components such as insulators, insulating tension pole, GIS voltage transformer and so on, the PD test can be performed under the general environment because of the merits of encapsulation, the PD level of our equipment can be lee than 3pC, and it can be added a HV bushing to perform the withstand voltage test at the same time.Small and compact dimensions resulting in minimum space requirements. Light-wight components. Rugged construction to withstand long transportation stresses. Direct flanging to the test object. High safety for tester because of encapsulation of all HV parts. Large range of application in conjunction with HV bushing for withstand voltage test. Built-in HV measuring capacitor and coupling capacitor. Built-in HV disconnecting switch to separate multipath test object connector to ensure the safety of HV testing.