Showing results: 1891 - 1905 of 2943 items found.
-
DRH1 -
DVTest Inc.
Ideal for applications from 2 to 18 GHz
-
-
Syntronic Microwave
The new generation of wide-band and ultra-wideband tuners have output frequencies as high as 4 GHz and 6 GHz. These frequencies are often out of sync with adjacent and peripheral equipment. The IFAT-8000 has an input range up to 8 GHz, can process a BW of 1000 MHz (or lower) and can convert/translate the IF to a frequency and bandwidth that is manageable by downstream assets. As times and applications change, the IFAT can change with the new needs.
-
SA-S -
EMC Test Design, LLC
RF Frequency Range: 1 Hz to 4.2 GHz. Low noise amplifier available above 500 KHz. Wide dynamic range: -151 dBm to +10 dBm. Resolution bandwidths (RBW) of 0.1 Hz to 250 KHz and 5 MHz. Includes a High Dynamic Range Measuring Receiver. 0.25 dB relative accuracy. 0 dBm to -125 dBm, 150 KHz to 1 GHz. 0 dBm to -115 dBm, 1 GHz to 4.4 GHz. Adjustable digital audio filters. Accurate AM and FM measurements
-
Analog Devices Inc.
Analog Devices, the world-class supplier of complete MMIC-based solutions for communication and aerospace and military markets, offers two successive detection log video amplifiers (SDLVAs) that operate over the 0.6 GHz to 20 GHz and 2 GHz to 20 GHz frequency ranges, respectively. They feature power limiter circuitry at the RF input and carry a Class 1A ESD rating (250 V HBM). They are available in miniature connectorized module packaging and are ideal for designers with space and power-constrained applications, including EW and ELINT receivers, DF radar, ECM, IFM systems, and missile guidance.
-
EHM and SHM -
Virginia Diodes, Inc.
VDI offers subharmonically-pumped mixers (SHM) and even-harmonic mixers (EHM) for a variety of applications between 50 GHz and 1700 GHz. These mixers use only planar and/or integrated diodes and provide state-of-the-art performance.
-
DiCon Fiberoptics, Inc.
DiCon’s 100 GHz WDM is designed to multiplex and demultiplex signals in multi-wavelength systems based on the ITU 100 GHz grid. The component uses a thin film filter mounted between a pair of GRIN lens collimators. The 100 GHz WDM is housed in a compact, environmentally stable package that offers superior resistance to humidity and temperature and is suitable for mounting on a printed circuit board or within a module.
-
SMB100B -
Rohde & Schwarz GmbH & Co. KG
The new R&S®SMB100B RF signal generator is all about performance and versatility in a small footprint. Outstanding spectral purity and very high output power combined with comprehensive functionality and very simple operation are some of the impressive features of the R&S®SMB100B. It offers a frequency range from 8 kHz to 1 GHz, 3 GHz or 6 GHz.
-
-
Virginia Panel Corporation
VPC's in-stock Mini Coax patchcords are available in 36" lengths and are rated up to 50 Ohms and 1 GHz. VPC's Micro Coax patchcords are available in 36" lengths and are rated up to 50 Ohms and 3 GHz.
-
DRH18–E -
RFspin s.r.o.
Frequency range: 1 GHz -18 GHz VSWR (max / AVG): < 3:1 / 1.35:1Impedance: 50 O (Ohm)Connector: SMA female / N femalePower (CW / Peak): 50 W / 100 W
-
Communications & Power Industries
• Frequency range 2 GHz to 40 GHz• Power levels up to 2.5 kW CW• Air, liquid and conduction cooling• Multiple stage collectors for improved efficiency• CW (continuous wave) & (pulsed) configurations available
-
R42XXE -
Elmika
The R42XXE Vector Network Analyzers are designed for measuring of S-parameters, VSWR and impedance of waveguide networks in the full frequency ranges of standard waveguides between 33 and 170 GHz. Frequency accuracy is ±0.2%. The measurement range of reflection factor modulus is from 0 to 1. The measurement range of reflection factor phase is from 0 to ±180° for 0.1< |Гx|<1 with accuracy ±7.5 o in 18-75 GHz frequency range and ±9.6° in 75-170 GHz frequency range. The measurement range of transmission factor phase is from 0 to ±180 o with accuracy ±(5+0.1 |Ax|) o for Ax >-50 dB in frequency range to 75 GHz, for Ax >-30 dB - to 170 GHz. Data can be displayed in the rectangular, Smith or polar diagrams. VNA requires Personal Computer with USB interface.
-
SPM Series -
Farran Technology Ltd
Farran offers fundamental (RF ≈ LO), sub-harmonic (RF ≈ 2xLO) and harmonic mixers (RF≈NxLO, where N=2, 4, 6 …) for a wide variety of applications from 26.5 GHz to 500 GHz. All mixers use planar Schottky diodes and provide state of the art performance in a small and lightweight package.High-performance sub harmonically pumped mixers are available in frequencies from 50 to 350 GHz and beyond.
-
16864A -
Keysight Technologies
136 channels, 350 MHz state, 12.5 GHz timing zoom, 2.5 GHz timing, 2 Mb depth standard15-inch (38.1 cm) color, touch-screen display for viewing and quickly navigating large numbers of signals and busesBuilt-in removable SSD drive, USB 3.0 ports and LAN for fast data transfer and storage of large amounts of data1.4 GHz trigger sequencer to ensure high-speed events are captured