Filter Results By:

Products

Applications

Manufacturers

Fluid

freely flowing substance.


Showing results: 331 - 344 of 344 items found.

  • Isocratic Pumps - Single Headed, Positive Displacement Piston Pumps

    ReaXus MX Class - Teledyne LABS

    The economical MX Class consists of single-headed, positive displacement piston pumps incorporating additional features for challenging applications. With pressure capability up to 5,000 psi, the MX Class can be used in both analytical and smallscale preparative HPLC separations. Further applications include demanding metering and dispensing, as well as Sample Injection, Infusion, or Cone Wash for Mass Spectrometers. Standard fluid path material is Stainless Steel.Features include available pressure monitoring with automatic pressure compensation, Pulse Dampener, integrated Prime-Purge Valve, interactive keypad control, and complete PC control and status through RS-232 and Micro USB 2.0 ports. Requiring minimal bench space for the performance, the MX Class will easily integrate into most workspaces.

  • Wafer Bonder

    AML - OAI

    Wafer bonding has found many applications in the field of MST, MEMS and micro engineering. These include the fabrication of pressure sensors, accelerometers, micro-pumps and other fluid handling devices. The process is also used for first-order packaging of silicon microstructures to isolate package-induced stresses. The OAI AML Wafer Bonder facilitates both the alignment and bonding to be performed in-situ, in a high vacuum chamber. For anodic bonding the wafers are loaded cold and heated in the process chamber. For high accuracy alignment the wafers are aligned and brought into contact only after the process temperature has been reached, thus avoiding differential thermal expansion effects which can compromise alignment. The AML Wafer Bonder is excellent for anodic bonding, silicon direct and thermal compression bonding applications. These features enable the bonder to be used with virtually any processing tool.

  • Refractometers

    PCE Instruments

    PCE Instruments carries a number of refractometer models including portable or handheld refractometer, digital refractometer and Abbe refractometer products used in food processing, canning, beekeeping, brewing, winemaking, distilling, pharmaceutical, manufacturing, machining, automotive, oil, petrochemical and water quality industries to measure the percent (%) Brix, salt content (salinity), water content, sugar content, Baumé (°Bé), Oechsle (°Oe), alcohol content or specific gravity (sg) of transparent or semitransparent fluids, liquids, formulas, suspensions, mixtures, dispersions, emulsions, concentrations, pastes and substances such as salt water or seawater, brines, fruits, juices, soft drinks, energy drinks, wines, liquors, condensed milk, jams, jellies, honey, industrial lubricants, antifreeze, ethanol, battery acids, propylene glycol, ethylene glycol, electrolyte solutions, paints, lacquers and chemicals.

  • Displacement Transducers

    Procter & Chester Measurements Ltd

    Pressure: Measures gas or liquid pressure. Pressure is an expression of the force required to stop a fluid from expanding. The transducer generates a signal from the pressure imposed upon it. Torque: Measures the torque (or twisting motion) on a static or rotating system. The static torque element has little movement and therefore more economic to manufacture and purchase. Rotary or dynamic torque is more complicated as the signal needs to be transferred using slip rings, wireless telemetry or rotary transformers/inductance technology so that the strain gauged shaft can continuously rotate. Displacement: Measures distance. The displacement transducers that PCM offer are slightly different to standard units. They have a strain gauge/wheatstone bridge. The benefit here is that if the customer has existing electronics that uses strain gauge/load cell technology, they can use them with these sensors.

  • Scanning Mobility Particle Sizer Spectrometer

    3938 - TSI Inc.

    TSI''s newest Scanning Mobility Particle Sizer SMPS™ spectrometer is widely used as the standard for measuring airborne particle size distributions. This system is also routinely used to make accurate nanoparticle size measurements of particles suspended in liquids. The National Institute of Standards and Technology (NIST) uses a TSI DMA to size 60 nm and 100 nm standard size reference materials. SMPS spectrometer sizing is a discreet technique in which number concentrations are measured directly without assuming the shape of the particle size distribution. The method is independent of the refractive index of the particle or fluid, and has a high degree of absolute sizing accuracy and measurement repeatability. TSI''s Model 3938 is the 3rd generation of SMP, trusted by researchers for over 30 years.

  • High-Flow Dual Head Pump

    ReaXus PR Class - Teledyne LABS

    The rugged PR Class consists of dual-headed positive displacement piston pumps that provide high accurate flows and excellent pressure capability for a variety of uses. Standard fluid path materials are Stainless Steel, PEEK, and optional Hastelloy. The pumps are designed for a wide range of Preparative and Semi-Prep Chromatography as well as SMBC (simulated moving bed chromatography) and many process and industrial applications. With 100 mL/min and 300 mL/min versions reaching pressures up to 4,000 psi the pumps will meet the most demanding LC and process needs.Features include an integrated Prime-Purge Valve interactive keypad control and complete PC control and status through RS-232 and Micro USB 2.0 ports. The PR Class provides the flow rates and pressures required for high throughput separations.

  • Dielectric Breakdown Voltage and Dielectric Strength

    ASTM D149 - National Technical Systems

    This test method covers procedures for the determination of dielectric strength of solid insulating materials at commercial power frequencies, under specified conditions. Unless otherwise specified, the tests shall be made at 60 Hz. However, this test method is suitable for use at any frequency from 25 to 800 Hz. At frequencies above 800 Hz, dielectric heating is a potential problem. This test method is intended to be used in conjunction with any ASTM standard or other document that refers to this test method. References to this document need to specify the particular options to be used. It is suitable for use at various temperatures, and in any suitable gaseous or liquid surrounding medium. This test method is not intended for measuring the dielectric strength of materials that are fluid under the conditions of test. This test method is not intended for use in determining intrinsic dielectric strength, direct-voltage dielectric strength, or thermal failure under electrical stress (see Test Method ASTM D3151). This test method is most commonly used to determine the dielectric breakdown voltage through the thickness of a test specimen (puncture). It is also suitable for use to determine dielectric breakdown voltage along the interface between a solid specimen and a gaseous or liquid surrounding medium (flashover). This test method is similar to IEC Publication 243-1. All procedures in this method are included in IEC 243-1. Differences between this method and IEC 243-1 are largely editorial. Note: The above information is taken directly from the test method Scope published in ASTM D149.

  • Vibration Diagnostics System

    VDS - Crystal instruments

    The Vibration Diagnostic System (VDS) is a vibration data management system designed specifically for the machinery Predictive Maintenance (PdM) community. It harnesses the graphic display capabilities of Crystal Instruments EDM Software for the work of machinery vibration analysts. It allows the user to quickly get to the data for a machine of interest and displays that data in the familiar Tri-axial or Single Axis view. Users can quickly compare other data from the same machine, quickly navigate back into the historical data of the machine, and quickly compare the data to that of other machines in the database. The software supports the construction of Average (a.k.a. baseline) data for a class of machines and allows easy comparison to that data as well. A full suite of cursors designed specifically for PdM analysis is provided for inuitive user interaction with the data.In addition to great graphics, an extensible machine modeling system was developed specifically for vibration analysis. VDS allows users to model machines based on the elements of the machine that can contribute to the vibration energy of the whole. Model bearings, rotors such as motor bars, couplings such as flexible and fluid couplings, account for slip in fluid couplings, model gears and pulley systems, and model turbines by accounting for each stage. The system is wide open, users can create new elements to use within a system. Users that may not want to do all that are provided with a comprehensive library of machine components such as AC and Induction Motors, Couplings, Gears, Pulleys, Pumps, and other components. Single and double gear shafts allows users to model many kinds of gear boxes with an unlimited number of stages. This ability alone lets users model their machines to view and use to keep track of vibration pickup locations, record the forcing frequencies of each part of the system, and attach attributes such as manufacturer and other part information.

  • Ultrasonic & Mass Flow Meters

    GAO Tek Inc.

    GAOTek offers high quality, affordable, secure and accurate Ultrasonic Flow Meters for sale to the United States, Canada and globally. Ultrasonic Flow Meters often have a sending and a receiving transducer for measuring the velocity of fluids to accurately calculate the flow of volume in a pipe by using sound waves, acoustic waves or vibrations with a frequency of >20 KHz. GAOTek offers a variety of top-notch Ultrasonic Flow Meters designed for different environments, from wide pipes to an all liquid environment, such as sea water, oil, sewage, alcohol, et al. GAOTek’s easy to use Ultrasonic Flow Meters come with a built-in printer and a built-in data logger. They provide accurate readings and have an accuracy rate of ±1% at rates greater than 0.2mps. They also offer multi-language menu selections, long lasting battery life for continuous usage, large LCD screens, and a huge storage.

  • General Inclinometers

    Columbia Research Laboratories

    Columbia's SI-701 Series of Inclinometers are electronic tilt sensors based on Force Balance Accelerometer technology. They produce high level low impedance output proportional to the sine of the tilt angle. Model SI-701B is a low cost general purpose sensor that can be up-graded with the addition of the Columbia "HP" torquer system (SI-701BI) for greater accuracy and ruggedness. A bi-axial version of both units (SI-702B) is also available. The Model SI-701BI is designed with an output circuit made for 4-20mA data transmission systems for industrial applications. The model SI-701FND is a fluid dampened premium performance inclinometer designed to produce accurate tilt data in extreme shock and vibration environments. The latest addition in the line is Model SI-701WPBI, a waterproof (to 150 feet) inclinometer which operates from a +15 volt supply with 4-20mA output. A single power supply powers both the sensor and the 4-20mA line driver.

  • Dynamic Imaging Particle Analysis Technology

    FlowCam® 8100 - Fluid Imaging Technologies

    The new FlowCam 8100 particle imaging and analysis system from global laboratory instrumentation manufacturer Fluid Imaging Technologies, Scarborough, Maine, features the company''s most advanced camera with the fastest imaging speed and double the image capture area to increase throughput, increase detection rates, and reveal more images and data. Imaging at up to 120 frames per second, the new FlowCam 8100 automatically detects thousands of individual particles and microorganisms in seconds, takes a high-resolution, digital image of each one detected and measures them in real-time based on their actual size and shape, not by an inference of their size and shape. Sampling at up to 100% efficiency with limited sample volumes as small as 200L, the company said, the FlowCam 8100 measures more than 30 different parameters from basic particle size, count and concentration to color, grayscale and advanced morphological characteristics such as circularity, elongation and fiber curl.

  • Ultrasonic Flowmeters

    Titan Enterprises Ltd

    Titan’s range of inline ultrasonic flow meters, now with ASCII streaming, is a genuine breakthrough in flowmeter technology. Utilising our patented ‘time-of-flight’ ultrasonic technology, the flow measurement devices are able to operate with excellent accuracy over wide liquid flow ranges.Work on developing a viable, accurate ultrasonic meter began in 2001 with a corporate decision to develop the best non-invasive small bore flow meter in the world as part of a long-term strategic plan. One of the foremost fluid engineering establishments (The Cranfield Institute of Technology) was commissioned to develop the device in collaboration with our R&D team at Titan. The resulting patented ultrasonic technology has led to an expanding line of Atrato ultrasonic flowmeters which have the adaptability to provide solutions for a number of OEM issues.Titan’s development of unique algorithms and techniques has resulted in a new generation of ultrasonic flowmeters that work well at low flow and deliver accurate measurements within a wide range of industrial processes.

  • Dual Piston Pumps for Low Pulsation Requirements

    ReaXus LD Class - Teledyne LABS

    The versatile LD Class consists of dual-headed, positive displacement piston pumps, delivering unmatched performance for analytical, flash, and small-scale preparative chromatography applications.The pumps are designed for high flow rate accuracy and low pulsation required for Analytical Liquid Chromatography (HPLC). Standard fluid path materials are Stainless Steel, PEEK, in addition to optional Hastelloy. Other available features include jacketed heads for temperature controlled processes. With 12 mL/min, 36 mL/min, and 100 mL/min versions, reaching pressures up to 6,000 psi, these pumps will meet the performance requirements of demanding HPLC needs.The high performance linear cams, along with automatic pressure compensation, provide precise flow rates for very accurate high pressure and low pressure gradients. Standard features include an integrated Prime-Purge Valve, Pulse Dampener, interactive keypad control, and complete PC control status through RS-232 and Micro USB 2.0 ports. The LD Class provides the precise flow and low pulsation for the most challenging separations.

  • Hydrostatic Test Chambers

    Hydraulic Technology, Inc.

    Test chambers are available to protect personnel during proof or burst testing. A few samples are pictured below. Chambers are manufactured in polished stainless steel with a clear polycarbonate door(s) for visibility during testing. Fluid port(s) are provided inside the enclosure, while all controls remain outside the enclosure for operator safety. In a hurry? Choose from our selection of Quick Ship Test Systems. basic units can ship within 24 hours or less and chamber systems within 2-3 days. we normally stock test chambers with nominal working area dimensions of either 24" wide x 24" deep x 15" high, 36" x 36" x 15", 48" x 24" x 15" or 72" x 24" x 12" with the door opening from the top. specify individual parameters at our customization page. Need a different size or configuration? No problem, simply specify dimensions and features that more accurately meet your particular requirements and we will be pleased to accommodate you. To customize a system to fit your particular application, please visit our customization page or give us a call at (916) 645-3317.

Get Help