Filter Results By:

Products

Applications

Manufacturers

Fixtures

orient and afix UUT.

See Also: Fixturing, Test Fixtures, Mechanical Fixtures, Vacuum Fixtures, Jigs


Showing results: 661 - 675 of 686 items found.

  • Flying Probe Tester

    Pilot 4D L4 - SEICA SpA

    The Pilot 4D L4 represents the best solution for those wishing to fully automate the flying probe test process, eliminating the need for continuous operator presence in order to manage the test system. Thanks to its integrated SMEMA conveyor, the Pilot 4D L4 can be combined with automatic load/unload magazines or lines, executing in-circuit, functional and visual tests of electronic boards in a completely automated mode. This is the ideal solution for medium and even high volume production test needs. The large test area can accommodate 21” x 24” boards (540 x 610 mm) board with split test. The ATE rack can be expanded with up to 1032 analog channels, connectable to an optional external bed of nails test fixture (TPM).

  • Power Cord Bending Tester

    SW-6 - Lisun Electronics Inc.

    SW-6 Power cord bending tester is fully designed according to the IEC standard, and can also be costumer-sized depends on the samples’ type and the costumer’s requirement. Specifications: • Power supply:AC220V 50/60HZ   12KVA • Control mode: PLC with touch screen and Servo motor. • Test Speed: 10~60times/min (Adjustable) • Test Degree: 0~540° (Adjustable) • Counter: 0~999999 (Can be pre-set) • Weight: 5N,10N,20N. 2Sets. (6Position type will have 6 Sets) • Position: 2/6 • Load Current: 0~20A (Adjustable) • Angle plate: Can check the test situation • Sample fixture: Can be costumer-sized. • Can do power line bending test (The User need prepare sample and power supply ), Can record the number of the sample’s work with load.

  • Biconical Antennas

    Schwarzbeck Mess Elektronik

    Biconical Antennas have dipole like characteristics (e.g. circular directional pattern in the H-plane,"8"-shaped in the E-plane, fixed phase center, comparable gain), with an enormous wide bandwidth achieved by the double cone elements. One of the earliest and worldwide most popular biconical antenna designs is the BBA 9106 with balun VHA 9103 B. During the last years a growing need for expanded frequency ranges arised, which led to the design of biconical antennas reaching down to frequencies of 20 MHz and up to 18 GHz and above. A further increase of bandwidth was achieved with qualified 4:1 baluns, providing a typical gain increase of approx. 6 dB at the lower frequency range. The biconical elements can be mounted and dismounted within a few seconds providing perfect contact repeatability thanks to special clamping fixtures. A small wrench made of insulating material is supplied with the balun, it is tied to the balun head and thus always available whenever needed. Biconical antennas can be used for many applications, in which half-wave dipoles have been used traditionally. An enormous reduction of measurement time can be achieved, because the time consuming tuning of the antenna elements to the half wavelength is not needed, an important condition for sweeped broadband measurements. In typical dipole applications several discrete frequencies are measured, in contrast the biconical antenna allows continuous sweeps, where site anomalies are discovered much easier.

  • Calibration & Demag.

    Model 8515-D - Magnetic Instrumentation Inc.

    The Model 8515-D is a medium-energy, high voltage, and capacitor discharge type ringing demagnetizer capable of desaturating Ceramic and Rare Earth magnetic materials. The Model 8515-D is easily adapted to a wide range of production and laboratory demagnetizing requirements. A modern solid-state electronic control circuit, coupled with a rugged, heavy-duty discharge SCR and fixture, make this demagnetizer a highly reliable, low maintenance unit. The electronic voltage control circuit prevents the Model 8515-D from being discharged before the preset energy level has been reached, avoiding incomplete magnet desaturation. An easy to read front panel meter monitors the capacitor voltage. The energy storage level can be easily changed in the field. Integral electrical interlock and fail-safe circuitry provide a high degree of operator safety.

  • 6 Sided Bed of Nails Testers

    BoxProber Family - Test Electronics

    6 sided Bed of Nails circuit board test fixture. Probes top bottom and all 4 sides. Central camming mechanism pull plates inward. Mechanically or electrically actuated options. Designed primarily for testing products in plastics. Side access electrically probes outside panel connectors. The unit will also optically read LEDs and key segments off LCD displays. Solenoids will press buttons and servos will turn selector switches. DC motors are used to adjust multiple turn potentiometers. Microphone will detect audio output tones. Top and bottom of circuit boards can also be probed if removable access panels are available. This unit will also probe all 6 sides of a circuit board. This is typically utilized in applications where connector testing is required.

  • Resistivity Meter

    Model 2180 - Magnetic Instrumentation Inc.

    The unit is compact and lightweight. The basic system is 7″ wide by 2.5″ high and 12″ long. When measurements are needed below approximately 100 micro-ohm-centimeters, the basic system is piggybacked onto a second enclosure that houses a power amplifier with a current gain of ten. The combined unit measures 7″ wide by 5″ high and 12″ long. The combined unit weighs 11.5 pounds. Two short cables interconnect the two enclosures for powering the power amplifier and routing the signals to the fixture or four point probe. The front panel of the basic system includes a 32-character backlit LCD display and a set of function keys. An easy-to-use menu will allow access to user defined parameters such as sample thickness, sample volume, and calibration constants; upper and lower alarm limits, relative measurements, and several others.

  • Universal Cable/Harness Tester

    LX-686 - Shenzhen Lian Xin Technology Co., Ltd.

    The system provides Chinese/English free switch operation interface,.·Up to 1500Vdc/1000Vac Test Voltage ,.·256 Max. Test Points , (Max of all series).·500 Max Files Memory,support USB or PC unlimited expansion,.·Arc detection level 0-9 ,auto prompt.·Adopted high resolution colour 640*480 TFT LCD ,.·Providing Single-End ,Multi-segment ,Standard ,and Spot test of wire..·Auto Scan and Auto Pin Search ,.·The system provides advanced instant open-circuit, short-circuit, continuity test,.·Intermittent Conductance Test,.·Intermittent Open/Short Test ,.·Full Programming Sequence Test ,.·Versatile I/O Ports for application ,.·Statistics and Print Function,.·Provide REMOTE interface, communicate with PLD auto test fixture,.·Provide personalized customization according to different requirements,

  • RF Coaxial Probes & Probe Positioner

    Fairview Microwave Inc.

    Fairview Microwave’s line of coaxial RF probes and RF PCB probe positioner are ideal for use with chip evaluations, signal integrity measurements, coplanar waveguide, substrate characterization, gigabit SERDES and test fixture applications. The RF coaxial probes provide return loss better than 10 dB and a maximum operating frequency of 20 GHz. The probes have a 3.5mm female interface, a pitch of 800 or 1500 micron and they can be cable-mounted. They feature gold-plated contacts and can be used by hand, with or without a probe positioner. Compliant coaxial GSG (or GS) pogo pins allow for a broad range of probing angles. The RF PCB probe positioner can hold coaxial probes, has articulated joints and delivers multi-axis positioner control. This positioner also boasts a magnetic mounting plate with on-off positioner switch.

  • PXI 5A Fault Insertion Switch 5-Channel

    40-196-101 - Pickering Interfaces Ltd.

    The 40-196 is a 10 Channel 5A Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Shorting relays on each channel enable UUT signals to be subjected to external user applied fault conditions or to be shorted to the adjacent signal in the same channel. Relays in line with the signal allow open circuit conditions to be simulated on either side or both sides of a channel signal pair. The switching topology of the 40-196 allows channels to be interconnected so that complex fault insertion systems can be constructed.

  • PXI 5A Fault Insertion Switch 10-Channel

    40-196-001 - Pickering Interfaces Ltd.

    The 40-196 is a 10 Channel 5A Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Shorting relays on each channel enable UUT signals to be subjected to external user applied fault conditions or to be shorted to the adjacent signal in the same channel. Relays in line with the signal allow open circuit conditions to be simulated on either side or both sides of a channel signal pair. The switching topology of the 40-196 allows channels to be interconnected so that complex fault insertion systems can be constructed.

  • Safety Compliance Test System

    EN 60601 - LXinstruments GmbH

    Test system for electrical safety compliance testing of medical products in accordance with EN 60601-1, 3rd edition.The system is equipped with three test fixtures which are connected in parallel order to reduce the number of setup tasks for different variants in the course of day-to-day manufacturing processes. Its purpose is to test medical products, e. g. patient monitors, which are employed at hospitals to monitor heartbeat and oxygen saturation.Based on the integrated electrical safety tester by Associated Research, in combination with an AC power source and a switching matrix, it is possible to fully automate tests like for instance AC/DC high-voltage tests, insulation resistance measurements, earth connection tests and leakage current measurements.The required occupational safety is provided by a high-voltage safety hood in accordance with EN 501191. The entire safety technology, as well as the control PC, is mounted in an aluminum-profile cart.

  • Vibration And Packaging Equipment

    LR Environmental Equipment Co. Inc.

    LR/RAD Drop Testers are available to simulate the impact a package would encounter during handling and shipment. The machine is air actuated to provide a reliable long life. Drop height ranges from 12-60 inches.The Drop Tester is supplied with a variety of standard features to earn its reputation as the industry standard: motor hoist with hand held control box to automatically raise and lower drop arm with package in place, Microswitch to preset drop height for repeatable drops, drop height indicator, remote hand switch actuated and a one inch vertical drop prior to drop arm swing to insure that package is not subject to rotation. LR/RAD Drop Testers are designed so packages may be released from any angle and be assured of landing in the same position. Special fixtures are available to allow for corner and edge drops.

  • Spectrum Analysis

    S95090B - Keysight Technologies

    The S95090B spectrum analyzer (SA) measurement software adds high-performance microwave spectrum analysis to PXI VNAs. With fast stepped-FFT sweeps resulting from optimized data processing, the SA software application provides quick spurious searches over broad frequency ranges. The S95090B software uses the PXI network analyzer's test and reference receivers to complete simultaneous spectrum measurements. Multi-channel SA measurements leverage the PXI VNA's internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The S95090B spectrum analyzer software application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy. Optional external attenuators should be connected with the VNA’s test ports to avoid receiver compression when measuring large signals.

  • Pneumatically Powered Bed of Nails Testers

    Automator Pneumatic Family - Test Electronics

    Designed to provide factory assembly line conveyor based pneumatically actuated full test automation. Interchangeable pneumatics and manual lever options provide operation as a fully automated tester or as a manual bench top tester. These functional interchangeable options allow this fixture to grow with you as your production volumes increase. Test plate changeover is a quick 2 minute job. 4 thumbscrews to change the bottom plate and 4 SHC screws to change the top plate. The top plate drops down and slides out with the connector assembly. The bottom plate lifts up and out. The new plates slide back in. All rear panel connectors are mounted to the aluminum bracket on the top plate. This whole top plate assembly slides out together eliminating wiring hassles. Double sided access plate sets use transfer pins to get the signals from the bottom plate up to the top plate.

  • Lever Handle Bed of Nails Testers

    Automator Manual Family - Test Electronics

    Designed to provide factory assembly line conveyor based pneumatically actuated full test automation. Interchangeable pneumatics and manual lever options provide operation as a fully automated tester or as a manual bench top tester. These functional interchangeable options allow this fixture to grow with you as your production volumes increase. Test plate changeover is a quick 2 minute job. 4 thumbscrews to change the bottom plate and 4 SHC screws to change the top plate. The top plate drops down and slides out with the connector assembly. The bottom plate lifts up and out. The new plates slide back in. All rear panel connectors are mounted to the aluminum bracket on the top plate. This whole top plate assembly slides out together eliminating wiring hassles. Double sided access plate sets use transfer pins to get the signals from the bottom plate up to the top plate.

Get Help