Filter Results By:

Products

Applications

Manufacturers

Showing results: 3361 - 3375 of 3637 items found.

  • Microwave Switches

    SMX-7XXX (Microwave) - AMETEK VTI Instruments

    The AMETEK VTI Instruments SMX-7000 Series of microwave switch cards extends functionality typically reserved for dedicated stand-alone systems into the PXIe from-factor. Single and dual slot configurations provide the ability to mix and match multiple switch configurations including SPDT, SP4T, SP6T and Transfer. Embedded virtual schematic control further simplifies setup and debugging allowing all relays to be engaged independent of application software and device drivers. Ideally suited for medium-to-high density automated test equipment (ATE), the SMX-7000 Series deliver uncompromised measurement integrity ideal for the most demanding aerospace, defense and communication applications.

  • SpaceWire-USB Brick Mk3

    326 - STAR-Dundee

    The SpaceWire Brick Mk3 is a USB 3.0 (also works with USB 2.0 and USB 1.1) to SpaceWire interface device that is suitable for use in all stages of SpaceWire equipment development: initial SpaceWire evaluation, instrument simulation, control system simulation, unit testing, integration support, and EGSE. The SpaceWire Brick Mk3 provides two SpaceWire interfaces, support for high speed data transfer, the capability to inject various types of errors on demand, the ability to transmit and receive time-codes and act as a time-code master, and comes complete with highly optimised host software for low latency transmission of SpaceWire packets directly to and from the host PC.

  • PXI 10A Fault Insertion Switch 6-chan 2-bus

    40-192-012 - Pickering Interfaces Ltd.

    This PXI fault insertion switch uses solid state switching elements and is capable of switching current up to 10A. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test: Open-Circuit. Short-Circuit between UUT connections. Short-Circuit to external signals. Through relays on each channel enable signals to the UUT to be set open-circuit. Fault Insertion Buses allow any channel to be shorted to any other channel and also enable any channel to be connected to an external signal such as Power, Ignition or Ground to simulate fault conditions. The module is supplied with 2 fault buses.

  • Temperature & Humidity Testing

    Environment Associates Inc.

    Environment Associates is outfitted with multiple chambers to suit all types of temperature and humidity testing needs, including: table-top, standard-reaching, fixed or portable walk-in chambers, and if needed, drive-in chambers. All Environment Associates test chambers are equipped with separate data-acquisition equipment for temperature and humidity monitoring. Our temperature and humidity chambers can be readily equipped with specialized data acquisition to digitally record chamber conditions and the test article at multiple data points. Many of our temperature and humidity chambers are equipped with high-performance, maximum-size compressors to produce superior ramp rates equal to or greater than 15°C per minute.

  • Photometers

    PCE Instruments

    Photometers to measure many parameters of water in industry, laboratories, field, gardening Photometers (Monofunction) to measure many parameters of water in industry, laboratories, field, gardening and in the environmental sector. and in the environmental sector. On our photometers website, we have 15 digital monofunctional photometers for the analysis of water (spare parts, reagents, and technical specifications included in the delivery). If needed, we can also offer other equipment for other water parameters. The control of water quality with solid devices is increasingly important, just as checking the quality of drinking water, industrial water and other wastewater. Take advantage of the properties of these photometers to measure various parameters such as chlorine, water hardness, nitrates, etc.

  • Radial Gearing Multipliers

    Mountz Inc.

    Mountz radial gearing torque multipliers are specifically designed to meet the needs of companies servicing plate heat exchangers in HVAC, chemical, dairy, marine, and petrochemical applications. Able to deliver repeatable, accurate amounts of torque, Mountz radial gearing torque multipliers prevent damage to plate heat exchangers during routine service, reducing the risk of expensive unplanned equipment downtime. The low profile heads of Mountz radial gearing torque multipliers allow them to fit into tight access points, helping you work more effectively. With over fifty years of direct industry experience, Mountz tools can be trusted with the costly assets your company relies on.

  • TEM Antenna

    Techimp HQ S.r.L

    TEM antenna is a partial discharge sensor designed to receive electromagnetic (EM) emissions from a PD occurring in the monitored asset (like MV switchgears or LV and MV induction motors fed by power electronic impulses). It is a broadband antenna with a flat response which makes TEM suitable in a number of different applications. It has been optimized to operate in a frequency range typical for PD activity and it was designed to provide maximum sensitivity and high gain. Its compact and robust design (passive sensor) makes TEM the optimal sensor for direct installation on medium voltage Switchgears and motors. It can be virtually applied in any electrical equipment provided that it has apertures or EM transparent surfaces.

  • USB Reusable Temperature and Humidity Data Logger

    DeltaTRAK

    This reusable logger can monitor temperature and humidity in facilities, storage and processing areas, clean rooms, labs, and during transport. It is equipped with an external sharp tip probe, providing the option to monitor internal core temperature. Data is available in PDF or spreadsheet format and used for various purposes, such as process or equipment verification and validation, thermal mapping, and documenting environmental conditions to meet GMP, GDP and regulatory compliance. Reports are analyzed to identify trends and patterns, and management decisions can be made to improve practices in areas such as processing and cold chain logistics. Data is easy to archive for record keeping, audits, and compliance with FDA, CDC, HACCP, FSMA and other regulatory requirements.

  • Earth Resistance Soil Resistivity Tester 2 / 3 / 4 Wire

    Model KM 1320 - Kusam Electrical Industries Limited

    KM 1320 Earth Resistance Soil Resistivity Tester is specially designed and manufactured for measuring earth resistance, soil resistivity, earth voltage, AC voltage. Adopting the latest digital and micro-processing technology, precise 4-pole, 3-pole and simple 2-pole method for earth resistance measurement, importing FFT and AFC technology, with a unique function of anti-interference capability and the ability to adapt to the environment, consistency of repeat testing, to ensure high precision, high stability and reliability for prolonged measure, which is widely used in electric power, telecommunications, meteorology, oil field, construction, lightning protection, industrial electrical equipment and other earth resistance, soil resistivity, earth voltage, AC voltage measurement.

  • 100 Ampere Micro OHM Meters

    Neutronics Manufacturing Co.

    Introduction: Measuring the line loop contact resistance by bridges is not the ideal method as the test current is only a few milli amperes. Thus the value is not the true value of the contact resistance. Model HL- 100 is a direct reading tester,  and uses a test current of 100A DC,  resulting in true v alue and accur ate measurements. Model HL- 100 adopts digital circuit technique and is used for measuring contact resistance of switch control equipments at test current of 100A DC. The measurements are accurate as the test is highly stable.HL- 100 is a new,  fully automatic micro controlled tester that measures contact resistance at 100A DC with built in printer. The advantages of HL-100

  • Frequency Tripling Test Transformer

    SBF - Wuhan Sangao Electrical Test Installations Limit Co.

    Specificationstripping test transformer1.easy to operate, with stable features.2.Can meet the induced voltage withstand request ofTtripping est transfromer,frequency tripling transformer, frequency tripling generator, frequency power generatorproduct features1.Easy to operate, with stable features.2. Can meet the induced voltage withstand request of the transformer, mutual inductor.product parameters1. Output voltage: three phases 380V 50HZ2. Input voltage: single phase 0~300V/0~500V(continuously adjustable) frequency:150HZ3. Output capacity: 5KVA and above.Harmonic distortion:<5%-8%4. No-load running time:≤5minutes5.duration of the measured equipment under rated voltage: 40 seconds

  • RF Milliwatt Meters

    Type NDB-2 and NDB-3 - National RF, Inc

    National RF’s Type NDB-2 and NDB-3 RF Milliwatt Meters are affordable pieces of test equipment for both the RF laboratory and the home experimenter. Both provide a digital reading of RF power in dB reference 1 milliwatt of power into a 50 ohm load (i.e. 0 dBm). The circuitry consists of a low noise logarithmic amplifier that drives a digital A/D converting meter circuit. The lowest power levels that can be read are about –73 dBm (approximately 40 microvolts or .00000003 milliwatts). The maximum power input should not exceed 10 milliwatts (+10 dBm or .010 watts) when inputed without attenuation. An internal attenuator is provided and described in the next section.

  • Crossing Control Bypass Switch

    XCBS-DL - Green Switch Innovations

    The XCBS-DL is permanently wired into each crossing warning system, and can be configured with either a removable or non-removable bypass key. Simply connect the track connection harness to the designated track connection terminals. To prevent unnecessary operation of the crossing warning system, insert the key and select "bypass", rotate the knife switch to "bypass" and the crossing is disabled. When in the "bypass" position, a Dummy Track Load is connected to the track wire connections in parallel with the rails and the crossing approaches are shorted, preventing unnecessary activation when track equipment is working in the crossing approach circuit. The opening of one track lead may be desired to prevent unnecessary activation with intermittent shunting on the crossing approaches close to the crossing.

  • 2-Slot USB/LXI Modular Chassis

    60-104-001 - Pickering Interfaces Ltd.

    This 2-slot USB/LXI modular chassis offers a small lightweight form factor, making it ideal for portable, benchtop, and space restrictive applications. The chassis is designed for desk or rack mounting and features remote control via USB or LXI Ethernet. Remote control over a network enables the switching function of a test system to be located as close as possible to the target equipment. The 60-104 chassis supports one or two 3U PXI modules and accepts Pickering's PXI products, it is the perfect platform to construct small scale applications. Possible systems include switching matrices up to 1104 crosspoints, 396 channel multiplexer or up to 36 channels of programmable resistor/sensor emulation.

  • 4-20mA Output Inclinometer

    LCF-2330 - Jewell Instruments LLC

    The LCF-2330 inclinometer series now includes a 4-20mA output signal option for applications that require long cable runs. This dual axis tilt sensor is fluid damped to minimize noise and vibration interference while also offering a sharp 1 µradian resolution. An internal temperature sensor is available and dual supply, ± 5 Vdc output is an option. The LCF-2330 is an excellent solution for rugged applications such as radar & antenna leveling, weapons platform leveling, barge and offshore platform control, deviation surveys, 2-axis machine tool leveling, bridge structural monitoring, submersible control feedback, offshore platform stability and manufacturing process equipment for the aerospace industry.

Get Help