Filter Results By:

Products

Applications

Manufacturers

Showing results: 3211 - 3225 of 3637 items found.

  • PMC Compatible SpaceWire Interface

    PMC-SpaceWire - Dynamic Engineering

    Utilize SpaceWire to communicate with the European Space Agency and NASA equipment utilizing the ECSS-E-50-12A specification. SpaceWire is configured using routers to create a heirarchical point-to-point system with high speed parallel paths. PMC SpaceWire implements SpaceWire in a convenient PMC format. With PMC you can install the adapter into PCI [PCIBPMC], cPCI [cPCI2PMC], or processor board pmc slots. The SpaceWire specification calls for LVDS signaling and a specific 9 pin micro-D connector. You can connect the PMC-SpaceWire to other SpaceWire compliant devices without electrical interface issues. 

  • Multi-Zone Gas Monitor

    HGM-MZ - IMR Environmental Equipment, Inc.

    The Multi-Zone Monitor provides continuous detection of refrigerant gas levels in up to 16 separate test zones and can be fitted with an optional two channel 4-20 mA current loop board for connection to remote monitoring equipment. Multi-Zone monitors retain a log of previous readings that can be easily accessed for analysis. Four relay contacts are provided that can be programmed to trigger external alarm devices in the event of a system fault, or if a leak (small), spill (medium) or evacuation (large) level of gas is detected, while audible and visual front panel indicators show alarm and fault conditions.

  • PC104 Switches

    Curtiss-Wright Defense Solutions

    Our PC104 switches provide systems integrators with a fast and powerful way to interconnect chassis, cards, and CPUs through switched Fast and Gigabit Ethernet links. These PC/104 Ethernet switches, optimized for size, weight, and power (SWaP)-sensitive embedded military and civilian computer network systems applications, enable reliable local area network (LAN) switching in extended operating temperature ranges and extreme shock/vibration environments. Ideal for connecting computers, cameras, sensors, and command and control equipment, these cards are typically deployed in manned and unmanned system platforms.

  • Substation Alarm ManagerAnnunciation and Data Viewer

    SAM - Applied Systems Engineering, Inc

    Applied Systems Engineering, Inc.''s Substation Alarm Manager (SAM) was developed in order to provide Power Utilities with a simple way to show the current status and data within a substation. SAM Substation Annunciator utilizes our extensive protocol library and allows for a wide variety of substation equipment to be monitored. Data can be acquired either by eavesdropping on an active circuit or directly polling an RTU/IED. Collection data is transmitted to SAM through the OPC protocol. This allows SAM to perform its alarm monitoring function either locally at the substation or at a remote site.

  • Test Analysis for Land Seismic Systems

    Testif-i Land - Verif-i Ltd

    Testif-i Land is an independent, powerful and cost effective software suite that allows you independently process instruments, source and receiver tests to confirm that the equipment is performing correctly and within specification. The software includes modules to perform comprehensive analysis of vibrator wireline similarity test data. Analysis includes a harmonic intensity plot which can highlight problems such as sub-harmonics which may not be seen on numerical results. Geophone pulse tests can be analysed using the receiver response module and test data from third party geophone testers can be graphed and statistics produced for ease of interpretation.

  • Sound Terminal Digital Audio Subsystems

    STMicroelectronics

    A breakthrough in digital audio systems, Sound Terminal™ digital audio ICs enable space-constrained audio applications, such as flat-screen TVs and MP3 docking stations, to deliver high-quality, room-filling sound. Using techniques such as Full Flexible Amplification (FFX), and integrating advanced DSP processing features such as multi-band DRC, this family enables a fully digital stream from sound source to loudspeaker. In application, this produces improved audio performance, reduced cost, and smaller size, making it possible for leading home-entertainment equipment manufacturers to deliver best-in-class audio experiences for consumers.

  • BMET PACK PRO

    Pronk Technologies Inc.

    BMET PACK PRO, a compact pack for all Pronk products and accessories with extra space for tools and 15.6-in. PC/tablet compartment. Includes the world’s smallest simulators — SC-5 SimCube® NIBP, OX-2 OxSim Flex® SpO2, and SimSlim® Multi-parameter — plus the new Safe-T Sim® Automated Safety Analyzer and next-gen FT-2 FlowTrax® IV Pump Analyzer with Pressure and Temperature Meters. With customized padded compartments, the BMET PACK PRO makes it easier than ever to travel with all your test equipment between hospitals and clinics.

  • High-Performance Intelligent Pod for Corelis Boundary-Scan Controllers

    ScanTAP 4 & 8 - Corelis, Inc.

    Boundary-scan has proven itself time and again to be a truly versatile interface for structural test, embedded functional test, built-in self-test (BIST), software debug, and in-system programming. Supporting such diverse applications requires equipment with high-performance specifications and extended features.Corelis ScanTAP pods are designed for use with PCI-1149.1/Turbo and PCIe-1149.1 high-speed JTAG controllers. Featuring 4 & 8 independent Test Access Ports (TAPs), up to 80 MHz clock rates, and advanced TAP capabilities such as analog voltage measurement, the ScanTAP family of intelligent pods is the ideal JTAG interface for high-performance environments.

  • Impulse Voltage Test Systems

    Fivestar HV Testing Equipment Co., Ltd.

    Impulse voltage test systems are used for impulse voltage testing of transformers, cables, gas-insulated switchgears (GIS), insulators, arresters, and other high-voltage devices. The test systems generate lightning impulse voltage (LI, 1.2/50μs), chopping lightning impulse voltages (LIC, front time 1.2μs, front, crest or tail chopped), and switching impulse voltage (SI, 250/2500μs) in accordance with IEC 60060-1; as well as IEC 60076-3 for transformers, and IEC 62067, 60840 and 60502-1 for cables), etc. And it can be used for steeping and oscillating impulse test by adding some extra equipment.

  • HIPOT Insulation Testers

    Laycock Systems

    Crown high voltage, transformer type hipot insulation testers are safe, easy to use for quick, positive determination of grounds, shorts, and broken wires in motors, transformers and other low voltage equipment or wiring systems. A turn of the selector switch gives a selection of seven voltages; 500, 1080, 1250, 1500, 1750, 2000 or 2500 volts calibrated to +/- 5% accuracy; NEMA recommendation for insulation test is twice normal voltage plus 1000 volts. Since this instrument has a capacity of 2500 volts, it readily accommodates all normal requirements.

  • LXI 24-Channel 1GHz Video Multiplexer

    60-721A-001 - Pickering Interfaces Ltd.

    This High Performance Video MUX is designed for the switching of RF signals in 75Ω systems at frequencies up to 1GHz. It is ideal for 75Ω monitoring applications that require a multiplexer to select one channel to be routed to measuring equipment. The automatic connection of unused channels into 75Ω terminations helps maintain signal integrity and minimizes the possibility of introducing unwanted responses. The common connection is also automatically terminated into 75 Ohm when unused. Front panel LED indicators adjacent to each multiplexer input connector provide an easy visual identification of the active channel.

  • Industrial Water Chiller

    Wewon Environmental Chambers Co, Ltd.

    The industrial chiller is a kind of cooling water equipment which can provide constant temperature, constant water flow speed and water pressure. Industrial process chiller is usually a closed loop system, which can provide instantaneous cooling for the factory or lab production process and save water by recirculating cooling.Industrial chiller system be divided to low temperature chiller and normal temperature chiller in the temperature control. The normal temp is generally controlled within the range of +4 ℃ to +35 ℃. The low temperature water chiller is generally controlled in the range of 0 ℃ to -100 ℃.https://www.wewontech.com/industrial-chiller/

  • EOS Tester

    KT-200SG - Kast Eng Co. LTD.

    This test instrument stands for the EMI(Electro Magnetic Immunity) ability test to the electric devices, electronic circuit boards & electric equipments. Recently this instrument is widly used in many companies in Korea & other countries to test the immunity to thier products-power supply, drive PCBs, communication systems, LCD display panels whether they are safe or not against the impulse & noise.All for the purpose, of this object, it generates 4 ~ 5 kinds of different impulse test waveforms.Output test voltage level : 5 ~ 200 V ImpulseOutput voltage polarity : Positive, NegativeType of waveforms

  • Isolation Power Panels for Healthcare Facilities

    Bender Inc.

    Standards such as NFPA 99 and CSA Z32 require isolated power systems in all areas deemed “wet procedure locations” in healthcare facilities. Isolated power systems offer an invaluable advantage - early detection of ground faults allows for critical systems to remain online in a single fault condition.Bender isolated power panels provide isolated power to electrical systems in operating rooms and other critical care areas. Utilizing the latest in technology, Bender equipment ensures that electrical ground faults are detected and located fast and automatically, in compliance with the latest standards and code requirements.

  • Physical Property Measurement System

    PPMS - Quantum Design Inc.

    The Quantum Design PPMS represents a unique concept in laboratory equipment: an open architecture, variable temperature-field system, designed to perform a variety of automated measurements. Available measurement options include all required hardware and electronics to immediately begin collecting publication-quality data, while the system is also easily adapted to custom user experiments. Sample environment controls include fields up to ±16 T and a temperature range of 1.9 - 400 K. The expandable design enables combining many features in one instrument to make the PPMS the most versatile system of its kind.

Get Help