Filter Results By:

Products

Applications

Manufacturers

Showing results: 91 - 105 of 127 items found.

  • Power Quality Analysers

    EPPE - KoCoS Messtechnik AG

    Power quality measuring systems with integrated fault recorder functionality for continuously and automatically monitoring electrical installations at all voltage levels. The measuring systems of the EPPE series continuously and precisely record all the electrical parameters of the power supply. They deliver detailed quality evaluations which reveal even the smallest of deviations and contribute to identifying the cause of disturbances.

  • Multi-Function Recorder

    TR-2000 - Ametek Power Instruments

    For all types of power system events, the TR-2000 Multi-Function Recorder provides all the information you need to capture the complete picture. With the true integrated functionality of the TR-2000, you have one place for all your answers. Simultaneously perform: transient recording, disturbance recording, phasor measurements, power quality analysis, and sequence of events recording.

  • Active Vibration Isolation

    I4 Series - Accurion GmbH

    The halcyonics_i4 is a state-of-the-art active vibration isolation system, which is ideal for isolating high-resolution measurement equipment from building vibrations and other disturbances. Besides the low-profile carbon-design, the system features straightforward handling for an easy operation. The two versions of the i4 system are multifunctional active vibration isolation systems for a variety of applications. This allows you flexibility for future applications with just one model. The isolation effect starts at 0.6 Hz, achieving the max. performance of -40 dB at 10 Hz, where 99.0% of the vibration is isolated.

  • EMI Test Receiver

    ESRP - Rohde & Schwarz GmbH & Co. KG

    The R&S®ESRP EMI test receiver has been designed for diagnostic measurements during development and for precompliance measurements to prepare products for final certification testing. It measures electromagnetic disturbances in the 10 Hz to 7 GHz frequency range, using either conventional stepped frequency scans or FFT based time domain scans to significantly speed up measurements.

  • MP CI set

    Langer EMV-Technik GmbH

    The MP CI set up to measure coupling impedance is used to determine EMC characteristics of connectors and cables. The coupling inductivity defines the coupling inductance of external disturbance on the shield or on the ground with the desired signals. If the coupling inductivity is considered in the construction set-up and the pin or wire assignment of connectors or cables, then the connectors or cables will be more interference-resistant. The MP CI set-up for measuring coupling impedance can be used for following measurements at connectors or cables: 1. measurement of a single signal (common mode) 2. measurement of a symmetrical signal (common mode) 3. measurement of a symmetrical signal (differential mode)

  • Revenue Metering

    Schweitzer Engineering Laboratories, Inc.

    SEL revenue meters offer bidirectional, full four-quadrant, and high-accuracy energy metering for generation, interchange, transmission, distribution, or industrial applications. They are also scalable for your application. Combining meters with SEL software provides a complete metering data management solution that allows you to optimize your power system by trending energy usage, identifying peak demands, and helping locate power quality disturbances.

  • Stainless Steel High Performance Flow Sensor

    2540 - Georg Fischer Signet

    The Signet 2540 Paddlewheel Flow Sensor offers field-replaceable electronics and transient voltage suppression (TVS) to provide greater immunity to large voltage disturbances (i.e. lightning) sometimes encountered in field wiring. Sensors can be installed in DN40 to DN600 (1 to 24 in.) pipes using the 1 inch NPT or ISO 7/1-R 1.5 threaded process connection. The sensors are also offered in a hot-tap configuration with a bleed valve service without process shutdown in pipes up to DN900 (36 in.). Both styles of sensors must be used in full pipes and can be used in low pressure systems.

  • Three Loop Antenna

    VVLA-30M - Lisun Electronics Inc.

    The three loop antenna VVLA-30M  is a standard measurement antenna according to CISPR15-2005/GB17743-2007 standard , it can work with LISUN EMI-9KA / EMI- 9KB EMI Receiver System for EUT magnetic field radiation measurement between X, Y and Z planes. The antenna measurement is accurate, switch conveniently and it can completely replace imported products.

  • Power Quality and Revenue Meter

    SEL-735 - Schweitzer Engineering Laboratories, Inc.

    The SEL-735 Power Quality and Revenue Meter passes accuracy requirements three times more stringent as the ANSI C12.20 Accuracy Class 0.2 standard. Advanced load profile trending, compatible with Itron® MV-90, DNP3, and Modbus protocols, ensures integration with practically any billing system. In addition to a full set of revenue metering features, advanced power quality monitoring will report costly system disturbances.

  • Phasor Measurement Unit

    Agile P847 - GE Grid Solutions

    The P847 Phasor Measurement Unit forms part of Alstom Grid's system monitoring and control. The devices is used to measure power system data in real time and report to the PDC (Phasor Data Concentrator) for visualisation, data storage and most importantly for running a variety of ‘on line’ and ‘off line’ applications in systems analysis and control. The ultimate goal is to run the system economically and preserve system stability following major disturbances.

  • Surge Generators

    Hybrid - Hilo Test

    Surge pulses occur due to direct or indirect lightning strikes in a circuit or by switching transients caused by switching inductive loads or short circuits. This leads to currents or electromagnetic fields causing high voltage or current transients. Surge voltages and currents can reach several thousands of volts and thousands of amperes. Our following Surge generators simulate these disturbances for all the necessary level in accordance with IEC / EN 61000-4-5 and IEC / EN 60060.

  • Programmable Wide Frequency AC Power

    PWF series - Preen AC Power Corp.

    The PWF series is a family of programmable AC power source with wide range of adjustable frequency, developed for aerospace or military’s 400Hz and 800Hz test applications, such as lab use, compliance test, and quality assurance. The PWF series consists of L series and M series, which have different output frequency range. L series provides 45~500Hz and 0~300V output, and M series provides 300~800Hz and 0-150V output. Users can select communication interfaces of RS-485, RS-232, and optional GPIB. The PWF series also have programming sequence functions of STEP and GRADUAL modes, three phase independent control, phase angle control, and disturbance function.

  • Power Management & MMI module

    H73000700 - 6TL Engineering

    This module, named “6TL-MMI”, is designed to be the interface between an operator and a SYSTEM as well as being a metered power distribution unit (PDU) for it. The module is providing also safety controls, data bus interfaces, temperature control and timers. The 6TL-MMI is suitable for any ATE, and specially for those based on CAN bus controlled devices, because in addition to the above functionalities, this module is also providing galvanic isolation up to 1500V for the CAN bus. This isolation will block potential disturbance towards the DUT.

  • Multi-Function Recorder

    Platinum 2.5K - Ametek Power Instruments

    For all types of power system events, the Platinum 2.5K Multi-Function Recorder provides all the information you need to capture the complete picture. This comprehensive fault recorder simultaneously performs transient, sequence of events and disturbance recordings, phasor measurements and power quality analysis. All of these functions are performed at the highest level so it will meet your needs of today and the future. In a deregulated environment, the Platinum 2.5K is the best tool to provide the necessary data to increase revenues and retain your customer.

  • ECM Noise Under RF Test System

    BK8020 - BaKo Co., Ltd

    The BaKo Type BK8020 ECM Noise Under RF Test System tests microphones under RF noise, using a ‘Direct Injection Test’ in the frequency range of 5MHz~2.5GHz with an amplitude modulated (AM) disturbance signal of 1kHz. You run the system using the controlling PC, which allows automatic configuration and which runs the test sequence automatically. When you finish testing, you can print data as an MS Excel report or save it for comparison and analysis.

Get Help