Showing results: 361 - 375 of 5316 items found.
-
695 -
Electronic Specialties Inc.
Great tool for accurate measurement of low current. Use with your graphing meter or lab scope to view current waveforms on fuel injectors, fuel pumps, primary ignition coils and more. Also works very well with digital multimeters. Resolution of 10 milliamps is low enough for most parasitic drain testing. In addition, the clamp opening of 1/2 inch is large enough to clamp over most negative battery cables for those parasitic drain tests.
-
DC1000A -
Voltech
To guarantee the quality and performance of inductive components such as inductors, chokes and transformers they are tested at their real-life operating point. If the inductor is designed to carry a DC current, then its inductance must be measured with that DC current present. Until now, these measurements were made by an LCR meter connected via special interfacing to a DC bias supply available only from the manufacturer of the LCR meter. The unique NEW DC1000A can be used with any precision LCR meter and connects simply into existing test fixturing.
-
DU2316/2317 -
Delta United Instrument Co., Ltd.
Leackage Current range display: 0.0001uA ~ 20.00mAAutomatic or Manual trigger with CHARGE/TEST/DISCHARGE100 sets of memory, can be saved test parameter and comparator setting, easy to use.Cover up free, system firmware upgrade can be update via RS-232, easy to maintenanceHi / Lo current limit setting & PASS/FAIL judgment240*64 Graphic LCD display, can be read the reading clearly and easier.User friendly programmable interface, easy to useProvided RS-232C and Handler combinatorial interface option, to meet your needed
-
Vanguard Instruments Company, Inc.
The EZCT-2000C is Vanguard’s third-generation microprocessor-based current transformer test set. Designed specifically for CT testing, the EZCT-2000C has the following outstanding features that can greatly increase productivity and save time during the commissioning stage:
-
MIZ-21B -
Zetec, Inc.
Our MIZ-21B handheld eddy current tester is a powerful handheld tester on the market for testing cracks, heat damage and corrosion. The MIZ-21B incorporates dual-frequency and digital conductivity testing with nonconductive coating thickness measurement.
-
LAD-1100 -
MULTI MEASURING INSTRUMENTS Co., Ltd.
●Selectable measuring range 30mA~30A with CT ratio 10:1 and 30A~3000A with CT ratio 100:1.●φ110mm CT window, possible to measure from leakage to big current up to 3000A.
-
TGPR-0800 -
Gemini Data Loggers Ltd.
A current input data logger that is supplied uncased so that it can be built into custom applications.The TGPR-0800 can be used to record the output from a number of industry standard 4-20mA sensors. Common applications include pressure and flow rate monitoring.
-
CA10 -
Teledyne LeCroy
The CA10 is a programmable and customizable interface device that seamlessly incorporates third party current transducers/transformers with Teledyne LeCroy oscilloscopes or motor drive analyzers. It allows the third party device to be recognized and operate as if it were a Teledyne LeCroy probe.
-
YAV90CIN -
6TL Engineering
12 Independent SPST relays Switching up to 8A 250Vac 12 current measurement channels 8x Sense connections General inhibit input CAN Control (or Ethernet with Ethernet to CAN Gateway) Drivers dll & VIs available
-
AXC7585 -
VX Instruments GmbH
Generate extremely short, fully regulated current pulses from 300 µs up to 1600 A. At the same time, carry out measurements directly on the DUT with the integrated VMU and CMU. Perfect for rapid semiconductor tests during production.
-
Taylor Dynamometer, Inc.
A precise, low-maintenance, rapid response and repeatable alternative to water brake technology, Taylor’s Eddy Current Engine Dynos provide low-inertia, air- or water-cooled operation for testing engines up to 966 hp (720 kW) in a range of markets.
-
Extech 382097 -
Extech Instruments Corporation
Extech's 382097 is a set of 100A Current Clamp Probes for Models 382095 and 382096 Power Analyzers. This clamp probe set features three probes with a 30 mm (1.2 in) clamp jaw. The 382097 comes with a two year warranty.
-
AXC7583 -
VX Instruments GmbH
Generate extremely short, fully regulated current pulses from 300 µs up to 1000 A. At the same time, carry out measurements directly on the DUT with the integrated VMU and CMU. Perfect for rapid semiconductor tests during production.ven Bauteilen.
-
Synectic Electronics
The SY018 DIN rail Voltage to 4-20mA signal converter is used to communicate analogue signals over long distances where electrical interference may be a problem. This solution is often used in the process control industry to collect the analogue values from a wide array of remote sensors. The converter is valuable because current signals are much less susceptible to noise than voltage signals. A voltage signal can be converted to current and broadcast over a long distance. 4-20 mA transmitters are common in the industry and used with high-quality sensors. The resulting signals can be use in controlling drives or to trigger instruments that have settable thresholds and limits.
-
HT9025 -
HT Italia Srl
HT9025 has been designed to measure AC/DC current up to 1000A, DC voltage up to 1500V and AC voltage up to 1000V in TRMS reaching CAT IV 600V and CAT III 1000V in compliance with safety standard IEC/ EN61010-1.