product
High Power, Contact, Receiver, 150 Amps, 2 AWG
610149101
Primary mating contact 610150101. (May mate with other ITA contacts, as well.)Specifications Operating Current 150 Amp Continuous using 2 AWG wireContact Resistance 0.35 mOhmsOperating Voltage 600VDC or Peak ACContact Body Cu AlloyInternal Contact Beams – Cu AlloyContact Plating Body - 10µ" Au over 100µ" NiInternal Contact Beams - 60µ" Ag over 50µ" NiOperating Temperature -40°C to +125°CT-Rise +40°C at 150 Amps+30°C at 125 AmpsContact Termination CrimpCycle Life 10,000 CyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force (lbs) 1.39
-
product
Standard 1.10 (31.18) - 4.80 (136.00) Switch Probe
TSP100-H150-1
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
product
Loop-Powered Transmitters and Drivers
4-20mA
Loop-Powered Transmitters convert the output from proximity probes, seismic sensors, into a 4-20mA DC current, which is proportional to the input being measured. The transmitter converts the displacement or vibration signal to DC voltage and/or current for a DCS or PLC system. They control a 4-20mA current loop for a specified vibration range (ex. 0-5 mils peak-to-peak). The transmitters have a two-wire hook-up, powered solely by the loop current and have a power supply range of 15 to 36 volts.
-
product
Safety Analyzer
SA-2000-INTL
The BC Biomedical SA-2000-INTL Base International Unit Model Features: Same as US BC Biomedical SA-2000 Model, but for users who need a power cord to meet their International Power Needs AAMI Load Earth/Ground Lead Resistance Earth/Ground Leakage Current Chassis Leakage True RMS Measurements 85 to 265 VAC Operation.
-
product
Zinc Oxide Arrester Tester
HTYB-3H / 430
Wuhan Huatian Electric Power Automation Co., Ltd.
Measurement and Analysis of Leakage Current for Zinc Oxide [MOA].
-
product
Ultra High 6.70 (190.00) - 11.80 (335.00) General Purpose Probe
EPA-4J-2
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
product
PXI 2A Multiplexer, 4-Bank, 16-Channel, 2-Pole
40-614B-007
This 4-bank, 16-channel, 2-pole version is part of the 40-614B High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
product
Power Analyzers
Multi-functions : WATT, VA, Whr, Power factor, ACV, * Built-in data hold function.ACA, Hz. * RS-232 output interface.* True AC power ( Watt ) & apparent power ( VA ) * Exclusive custom exclusive design LSI circuit, provides highmeasurement. accuracy, reliability and durability.* True rms display for ACV, ACA. * Built-in over input indication.* Supper large LCD, easy to read-out, display the Watt, * Power supply by batteries.Power factor, Voltage & Current value at the same time. * Built-in low battery indicator .* Auto range. * Durable plastic housing case with handle.
-
product
PXI 20 x SPST 10 Amp Power Relay Module
40-160-003
The 40-160 module has a choice of 10 x SPST, 20 x SPST or 10 x DPST Power Relays, suitable for switching inductive/capacitive loads up to 10A at 250Vac.Power Relay Modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids.It is suitable for applications requiring switching of either mains voltage or DC current.
-
product
Alternate 1.10 (31.00) - 3.40 (86.00) Battery Probe
BIP-3-1
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 60Recommended Travel (mm): 1.52Mechanical Life (no of cyles): 250,000Overall Length (mil): 511Overall Length (mm): 12.98
-
product
Battery Discharge Tester
HTFDK / 796
Wuhan Huatian Electric Power Automation Co., Ltd.
Through continuously regulating discharge current, constant discharge current at set value can be realized.
-
product
Current Sensing
voltage-output, current-sensing amplifier family that integrates an internal shunt resistor to enable high-accuracy current measurements at common-mode voltages that can vary from 0 V to 36 V, independent of the supply voltage. The device is a bidirectional, low- or high-side current-shunt monitor that allows an external reference to be used to measure current flowing in both directions through the internal current-sensing resistor sensor. The integration of the precision current-sensing resistor provides calibration equivalent measurement accuracy with ultra-low temperature drift performance and ensures an optimized Kelvin layout for the sensing resistor is always obtained.
-
product
Source Measure Units
NGU
Thanks to their extremely high accuracy and fast load recovery time, the R&S®NGU source measure units (SMU) are perfect for challenging applications. A special ammeter design is used to precisely measure current drains from nA to A in one pass – no need to make multiple measurement sweeps. The instruments’ short recovery times enable them to handle fast load changes that occur, for example, when mobile communications devices switch from sleep mode to transmit mode. With high speed data acquisition, every detail is detected down to 2 μs resolution.
-
product
Lens Antennas
A lens antenna is a directional antenna that uses a shaped piece of microwave-transparent material to bend and focus microwaves by refraction, as an optical lens does for light.[1] Typically it consists of a small feed antenna such as a patch antenna or horn antenna which radiates radio waves, with a piece of dielectric or composite material in front which functions as a converging lens to collimate the radio waves into a beam.[2] Conversely, in a receiving antenna the lens focuses the incoming ...show more -
product
Near Field Probes 1GHz - 10 GHz
SX set
The SX1 set consists of 3 passive near field probes for making measurements in the development phase of E-field and magnetic field with a high clock frequency in the range from 1 GHz to 10 GHz. The probe heads of the set SX allow for measurements close to electronic assemblies, e.g. on single IC pins, conducting paths, components and their connectors, to localize interference sources. Field orientation and field distribution on an electronic assembly can be detected through trained use of the ne...show more -
product
DC Hipot Tester
296
Our Model 296 is a simple-to-use Hipot Tester with the built-in ability to easily test Ground Continuity (Low Current Continuity). The 296 is capable of performing Hipot Tests in both AC & DC currents. You need a Hipot Tester that includes all the features you need to get the job done, the 296 has what you're looking for Make testing simple with common sense security settings.
-
product
Series Precision Multi-Ratio Current Transformers
PMT25090
Power Measurement Technologies Inc.
Precision two-stage toroidal current transformers find application as the reference in determining the accuracy of instrumentation current transformers.
-
product
Light 0.83 (24.00) - 2.00 (57.00) High Performance Bias Ball Probe
POGO-1L-2-S
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Line Mounted Fault Indicator
LineTroll 110Eμ
Linetroll 110E contains magnetic and electric field sensors surveying line current and line voltage. The magnetic sensor automatically adapts to line current, detecting preset current increases. The electric field sensor is monitoring the presence of line voltage. The sensor signals are processed and compared with user set alarm criterias.
-
product
PXIe-4137, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit
783761-02
PXIe, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4137 is a high-precision, system source measure unit (SMU). It features 4-quadrant operation and sources up to 40 W of DC power and can pulse up to 500 W. Analog-to-digital converter technology helps you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module also can maximize stability and measurement accuracy with So...show more -
product
Alternate 2.58 (73.00) - 6.00 (170.00) High Performance Lead Free Probe
LFRE-25V-6
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Source Measurement Unit
SMU32
The SMU32 is a low cost solution for V/I source andmeasurement. The SMU32 offers PMU/DPS in acompact, 3U PXI form factor. The SMU32 supports -1Vto +10V +- 32 mA FVMI/FIMV modes. 8~32 PMUs canbe ganged to DPS for high current driving.
-
product
Primary Injection Test Systems
Primary current injection testing is utilised in high current/high voltage scenarios found at large electrical installations such as substations. A large current (between 100A and 20,000A depending on system specifications and test requirements) is injected directly on the primary side of the electrical system such as a circuit breaker. The objective of the test is to identify how the system operates under various levels of current load.
-
product
Digital Clamp-on Meter
DCM-2608
AC current up to 1500A;DC current up to 2000A. AC voltage up to 750V;DC voltage up to 1000V. Resistance up to 40M£[. Frequency up to 400kHz. Capacitance measurement
-
product
Power modules
G.R.A.S. Sound & Vibration A/S
It provides polarization voltage for the transducer, ensuring that the microphone gets the charging voltage it needs.It provides supply voltage for the microphone preamplifier. The preamplifier acts as a unity gain impedance converter. It provides a certain amount of line drive capability by providing a low output impedance and output current, making it possible to transmit the signal from the transducer to the Power Module without significant degradation.A power module can provide amplificatio...show more -
product
4 Discrete/Switch I/O Channels (±100 V, 3 A/Ch.)
DT3
The DT3 module (the enhanced version) feature 4 independent, high current, isolated, programmable channels that can be used for input voltage measurements (±100 V), or as a bi-directional current switch (up to 3 A per channel). When programmed as a switch with the switch closed, both the current through the switch and the voltage across the switch can be monitored. These modules include diode clamping on each channel. Clamping is useful for inductive loads, such as relays and short circuit protection.
-
product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1B
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
product
Digital Coating Thickness Gauges
The Elcometer range of digital coating thickness gauges has been specifically designed to provide highly accurate, reliable and repeatable coating thickness measurements on almost any substrate, whether ferrous or non-ferrous. Dry Film Thickness can be measured on either magnetic steel surfaces or non-magnetic metal surfaces such as stainless steel or aluminium using a digital coating thickness gauge. The principle of electromagnetic induction is used for non-magnetic coatings on magnetic substrates such as steel. The eddy current principle is used for non-conductive coatings on non-ferrous metals substrates.
-
product
Light 0.83 (24.00) - 2.00 (57.00) High Performance Lead Free Probe
LFRE-1H-2
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
16 Relay Output Board, 8 Isolated Digital Input Channels, 24V
APCI-2200-16-8
16 electromechanical relays with change-over contacts ? Max. switching voltage for the relays: 60 V/DC, 48 V/AC ? Max. switching current: 1 A ? Short response time ? Option: 8 input channels for AC voltage, optically isolated, input voltage range: 12 - 24 V DC ? Watchdog: software-programmable release, stop and time selection.