Filter Results By:

Products

Applications

Manufacturers

Showing results: 151 - 160 of 160 items found.

  • Elemental Analyzers for Carbon, Sulfur, Oxygen, Nitrogen and Hydrogen

    HORIBA, Ltd.

    HORIBA Scientific provides inorganic elemental analyzers for a wide range of applications based on the inert gas fusion technique and high frequency heating combustion in oxygen stream.The EMIA Series for Carbon and Sulfur analysis and EMGA Series for oxygen, nitrogen and hydrogen analysis strongly rely on HORIBA’s experience as a pioneer in Non-Dispersive Infrared (NDIR) technology. Both EMIA and EMGA designs meet all requirements for the metallurgical industry. These instruments also help scientists working in other application fields such as semiconductor, battery materials, ceramics and more.

  • AC Loadbanks

    Hillstone Products Ltd.

    Regular load bank testing of generators provides an essential health check service to prevent diesel engine failure due to wet stacking. Wet stacking occurs due to under loading of the genset which results in wet un-burned fuel building up in the engine. This fuel build up will over time line the combustion chamber cylinders and cause a reduction of the engines rating and efficiency which will ultimately cause premature failure of the generator. Running the generator on load of 50% - 100% of the genset rating will allow the engine to reach the recommend operating temperature, which will burn off the choke deposits.

  • Pitot Tube Flow Meter

    PTFM-1000V2 - HORIBA, Ltd.

    The Pitot Tube Flow Meter, PTFM-1000V2 is a standalone interface for measuring exhaust gas flow rate of combustion engines. The system uses the tried-and-tested pitot tube principle with high-frequency transducers to accurately measure highly pulsating exhaust flows with a sampling rate of 1kHz. This rapid capture rate ensures that any pulsations or exotic behaviour in an engine is measured, and the unique design of the PTFM pitot tube means reverse flows can be measured with the same guarantee of sensitivity. The interface can be run standalone with a laptop, or seamlessly integrated to run alongside an analyser system without adding any more steps to the test cycle process.

  • Sample Conditioner

    PCA-400 - Bacharach, Inc.

    Bacharach’s active sample conditioner is used to enhance the performance of the PCA® 400 combustion and emissions analyzer in heavy industrial and commercial settings. The PCA® 400 provides accurate readings for CO, O2 and NO with a standard probe. Bacharach also offers optional Viton™ tubing with the sample conditioner to eliminate sample dropout, ensuring accurate results in applications where NO2 and SO2 measurements are necessary. The sample conditioner removes water vapor from the stack gas sample, preventing the formation of water droplets inside the analyzer’s probe hose. Water in the sample hose could absorb a portion of the gas sample and result in lower than actual readings of NO2 and SO2. The water extracted from the gas sample is pulled out of the thermoelectric (Peltier) cooler and into a water catch pot. The dry, conditioned flue-gas sample is then passed through to the PCA® 400 for analysis, ensuring a clean, dry, accurate air sample. This also prevents water passing into the instrument and possibly damaging the sensors or other components.

  • Crank Angle Measurement System

    CP-5110B Detector/CA-6000B Amplifier - Ono Sokki

    CP / CA series are systems that detect the rotation angle of the engine crankshaft composed of CP-5110B Fiber Optic Crank Angle Detector, CA-6000B Crank Angle Amplifier and CP-5120 / 5130 Slit disk.CP-5110B Fiber Optic Crank Angle Detector makes it possible to detect the crank angle required for various engine performance tests such as combustion analysis with high accuracy and high response. As it has a light projecting and receiving method with an optical fiber, it provides outstanding vibration and noise resistance without a built-in electric circuit in the detector.CA-6000B Crank Angle Amplifier inputs a signal of crank angle detector and outputs a TTL level angle signal and a 1P / R pulse signal.

  • Rubber Testing Equipment

    Dongguan Amade Instruments Technology Co., Ltd

    Rubber testing equipment are used to test the physical properties, chemical properties, thermal properties of uncompounded and compounded rubbers at prescribed conditions to help manufactures or researchers in comprehending the characteristics, updating the formula and improving product quality. Including volatile component, ash content, Mooney viscosity, vulcanization curve, Mooney scorch time, hardness, tensile properties, tearing, the compression performance, impact, friction resistance, fatigue resistance, peel strength, vertical & horizontal combustion, smoke density, limiting oxygen index, the flame spread rate, the surface resistance, surface resistivity, volume resistivity, the breakdown voltage, dielectric strength, dielectric loss, antistatic properties, Aging test (UV, Xenon lamp, carbon arc lamp, ozone) etc.

  • Multi-Stage Injection Measurement System

    Ono Sokki

    Common rail fuel injection system in diesel engines is a fuel injection system which improves output performance and fuel consumption by purifying exhaust gas (soot, NOX) and reducing noise and vibration.The fuel is completely burned by being sprayed in the form of mist which burns easily at high pressure, and furthermore the combustion timing is optimized with electronic control.In this common rail injection system, injection timing by an electric controlling has great effect on the performance of an engine. So measurement of injection amount, injection rate, and injection timing are very important. FJ-8000 series Multi-Stage Injection Analyzer is able to measure those parameters for every 1 cycle by simulating in the environment which is near to an actual vehicle running.

  • Stack Gas Analyzer

    ENDA-7000 Series - HORIBA, Ltd.

    After decades of experience in precise stack gas measurement, HORIBA's brand new ENDA series represents the ultimate stack gas analyzer. With enhanced lower cost and reduced maintenance time, high sensitivity, and usability, we focused on the users' point of view. The ENDA-7000 is designed to continuously measure the concentrations of NOX, SO2, CO, CO2, O2, and NH3 in stack flue gas streams. The model is offered in dozens of combinations based on your measurement requirements. The ENDA-7000 uses an extractive method which measures undiluted sample gases, and is very suitable to stack gas measurements such as shale gas, LNG, or biogas and other combustion applications. The ENDA-7000 is an excellent choice for measurements in power generation facilities, boilers, furnaces, steel manufacturing, cement plants, pulp and paper mills, etc.

  • UV Cameras

    Inframet

    Solar blind UV cameras are imaging devices optimized to detect ultraviolet light of wavelengths below about 280nm. Such cameras are insensitive against sunlight due to negligible sensitivity to visible and long wavelength UV light. Solar blind UV cameras are used in a series of applications like corona detection, fire detection, combustion analysis, plasma research, testing UV lamps, etc. However, highly sensitive corona detection is the main mass application and these devices are of crucial importance in electric power industry. These imaging devices enable easy detection of degraded insulators of high voltage transmission lines, distributions and substations. They can see the emission of UV light when discharges occur at defect insulators. From design point of view solar blind UV cameras are actually bispectral imaging systems built by combining true UV camera with typical visible camera. These bispectral imaging system generate output image as overlay of typical visible image with UV image of analyzed UV source.

  • Portable Sulphuric Acid Dewpoint Temperature Monitor

    Walsn Enterprises Ltd.

    The fuels used in boilers, such as coal, heavy oil and natural gas, contains S. during the combustion process, S and O₂ form SO₂, and a small amount of SO₂ is converted into SO₃ under catalysis of Fe₂O₃, V₂O₅ and other catalysts. Under normal circumstances, the volume of SO₃ in the boiler flue gas is 1×10-6~50×10-6, and the water vapor is about 10%. When the temperature of the flue gas is below 200°C, SO₃ and the water vapor are completely combined into H₂SO₄ vapor. A small amount of H₂SO4 vapor will significantly increases the acid dew point. When the surface temperature of the boiler heat exchange equipment is lower than the flue gas acid dew point, the H₂SO₄ vapor will condense on the surface to become sulfuric acid solution with a concentration of about 80%, which will adhere to the surface of the heat exchanger and cause acid corrosion. Typical equipment that is prone to corrosion includes air preheaters, induced draft fans and flue walls.

Get Help