Showing results: 676 - 690 of 931 items found.
-
Underwriters Laboratories Inc.
The Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions From Indoor Sources Using Environmental Chambers, an expanded standard for what is commonly known as California Specification 01350, is one of the most widely used standards to evaluate building and interior products for low chemical emissions.
-
Vidac Solutions
Partial Discharge testing is a way of detecting voids or imperfections in insulators that would lead to overheating and breakdown under normal operating conditions. Due to the nature of the signal being measured, this test is very susceptible to electronic and RF noise and a proper corona-free properly isolated test chamber is required.
-
Yamaha Fine Technologies Co., Ltd.
Yamaha Fine Tech's proprietary low vacuum test realizes highly reliable measurement. With our proprietary low vacuum chamber system and helium gas detector, highly reliable inspections are conducted. Easy operation and easy maintenance are realized by a full fail-safe and sophisticated control system.
-
Model T300M -
Teledyne Advanced Pollution Instrumentation
The Model T300M CO analyzer measures low to mid ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.
-
PSE Instruments GmbH
The potential induced degradation (PID) is addressed with the standard IEC TS 62804-1. The standard defines two methods that enable analyzing occurring PID effects in a specific PV module type. PSE AG offers the necessary equipment for the test in a climate chamber. The test equipment can work with any climate chamber on the market and is delivered turnkey. It comes with all necessary equipment, high voltage power sources, sensors, data acquisition and software.
-
AM-MCPC-RS -
Finna Sensors
PC-Based lab/production moisture analyzer connects through RS-232 Serial Port. Designed for nuts, granules, powders, pellets, chips, or flakes. Includes two sample cups, MCPC-RS test chamber, windows PC-based software, and more. See product link for complete features and minimum computer requirements.
-
GT-1 -
Physitemp Instruments
GT-1 Air and Gas Probe - 24'' #304 stainless steel shaft. Wooden Handle. For instant readings of temperature gradients in environmental chambers, freezer boxes, etc. Diameter is .3/16'' diameter. Immersible. Maximum temperature 200°C, Time constant Seconds. 5 foot lead. Not isolated.
-
SYS-28 -
Eddy Co.
This 28" box coater has a separately ventable top chamber, to allow for faster parts changes and increased productivity. It also is equipped with our FTC-620 flip controller. The flip and rotation motors can be seen on the top. This system uses a Varian tri-scroll pump and a bottom mounted 16" APD cryopump.
-
8801B Tester -
Hydraulic Technology, Inc.
This hydraulic hose tester is manufactured to, and meets all the requirements of, military specification MIL-T-25456B and federal specification A-A-52687. Enhanced safety for operating personnel is achieved by utilizing the optional 8801HT integral test chamber which was designed specifically to fit to all our 8801B and 9801B testers.
-
MODEL PDS-6000 -
TEK-VAC INDUSTRIES Inc.
One centrally located robot with four access ports. Four process chambers, one central loadlock, and one clean room load lock. Two 330 liter/second turbomolecular pump serving all process chambers. Options of 104 CFM Roots Blowers each backed by a 27 CFM rotary vane pumps.
-
TDK RF Solutions Inc.
By combining the latest in LED technology with the unmatched illuminating dynamics of prismatic glass, this High Bay LED luminaire brings a superior, incomparable proficiency and reliability to the table. With its remote driver capability, the TDK HBLED-540 High Bay LED Light Fixture is ideal for EMC chambers with minimal RF emissions.
-
ARA 01 -
York EMC Services Ltd
The Active Receive Antenna (ARA 01) is a compact emissions antenna with an antenna factor comparable to a conventional wideband passive antenna such as the Bilog. The small size makes the ARA 01 particularly suitable for use in anechoic chambers; however it can also be used on an Open Area Test Site (OATS) or at on-site locations.
-
KP Technology
KP Technology offer a range of Kelvin Probes that work under ultra-high vacuum conditions, choose from single-point or scanning probes to add to your existing vacuum chamber, customize the UHV corner cube or consider the newest addition to the range, the Ф4 ultra-high vacuum scanning Kelvin Probe system.
-
UI-TX40 -
Unuo Instruments
Horizontal Flammability Tester – Horizontal Flammability Chamber is used to test textile and material used in vehicles horizontal burning rate when exposure to a small flame. Horizontal Flammability Test Method includes ISO 3795, ASTM D5132, JIS D1201, SAE J369, FZ/T01028, GB/T8410, GB/T20953 and etc.
-
Greenlight Innovation
The Multi-channel system includes turnkey integration of Greenlight's environmental chamber, load bank, power supply and data acquisition system, all housed in 19" rack towers.