Calibration
maintains accuracy of test asset by correcting out of specification conditions.
See Also: Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References
-
product
Dual Space Electro-hydraulic Servo Universal Testing Machine
WAW-E Series
Jinan Testing Equipment IE Corporation
WAW-E series computer control servo-hydraulic testing machine is suitable for testing tension, compression, bending and shearing strength of various metallic & non-metallic materials. Equipped with the electronics, computer &software packages, the servo-hydraulic tester of dual space is capable of controlling the test procedures by the predetermined programs. The computer control servo-hydraulic testing machine can also display, record, process and print the test results. The test curves...show more -
product
Test Equipment Calibration
EMC Technologies can provide convenient, local, NATA accredited calibration services which greatly reduces lead time and costs for EMC test equipment. In the past these items had to be sent overseas or to expensive government laboratories. We can calibrate these items against common standards such as CISPR 16 (and subparts), IEC 61000-6-X series, ANSI C63.4, ANSI C63.5 and ARP 958.
-
product
Reusable ICP® Strain Gauge
This high-resolution dynamic alternative to bond foil strain gauges uses a quartz sensing element in a durable, titanium housing. It has 0.0006 microstrain resolution, 5 volt output, 100k Hz frequency response and 0.5 gram mass for lightweight test articles. The reusable sensor comes with a calibration certificate, attaches to the test specimen in 60 seconds and is removed in 10 seconds.
-
product
Bluetooth Enabled® Conductivity/TDS/Salinity/Temperature Pen
UltrapenX2™ PTBT1
Accuracy of ±1% of READING, ±0.2% at Calibration Point. KCl, NaCl and 442 Natural Water™ Modes. Automatic Temperature Compensation. Autoranging. Measurement Storage with Time, Date and Location. Export Stored Measurement Data Via Email. Proprietary Cell Design. Rugged Design with Aircraft Aluminum Body. Durable, Epoxy Encapsulated Electronics. Powered by One N Type Battery (Included). Waterproof.
-
product
Light and Energy Meter
Model 659
UV Light and Energy Meter for use with all wafer steppers. For over 45 years, OAI is a world leader in UV Light and Energy Measurement Instrumentation used for reliable accurate calibrated control of the photolithography processes in the Semiconductor, MEMS, Wafer Packaging and Wafer Bumping Industries. The New Model 659 is an advanced UV exposure analyzer specifically designed for use with all wafer steppers including high intensity wafer steppers. This meter averages up to 400 exposure reading...show more -
product
NIST Calibration for D410-A
D410-A-CCNIST
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
product
Pressure Calibration Custom Systems
Our custom systems integrate standard Fluke Calibration products, pressure generation and control accessories and/or data acquisition hardware to meet customer requirements. Systems may be mobile calibration carts or rack mounted instrument panels or benches. 7250-sys Ruska gas pressure controller system, and engineered systems customized to fit your application needs.
-
product
GFS Primary Gravimetric Flow Standard
The GFS dynamic gravimetric mass flow calibration system allows users to maintain the accuracy and traceability of molblocs or other high precision devices using the same primary reference used by Fluke Calibration. GFS is a true mass flow reference suitable for use in premier measurement institutes who require the lowest measurement uncertainty.
-
product
Acoustic Calibration Services - IEC
Acoustic Calibration Services - IECMake sure you measure correctly! We offer traceable acoustic calibration services according to international IEC and ANSI standards and ensure that your instrument accurately indicates the required measurement parameters. Calibrations are documented, traceable, and digitally signed in cooperation with an accredited calibration laboratory.
-
product
ACCUplace Grid Indexing Pattern
AP-G Series
Ensuring precise motion and positional accuracy is critical for a number of video analysis systems and automated measuring instruments. The AP-G series is ideally suited for calibrating such elements, in addition to its uses in determining stage squareness, and travel distance image analysis and visual inspection systems where precise motion must be calibrated and measured. All AP-G targets have number/letter indexed columns and rows for easy calibration and are offered on four standard materials; Glass (CG) Opal (OP) Photopaper (RM) and Film (TM).
-
product
Sensor Database Implementing Imc Plug & Measure Technology
imc SENSORS
imc SENSORS is a ready-to-go, universal database application for administering and editing sensor information. Along with values for smart sensors defined in IEEE P 1451.4 (TEDS), selections of additional sensor properties can be freely entered. These can be set, edited and viewed in freely configurable tabular views, e.g., the sensor's technical data information, as well as its calibration values.
-
product
Air Data Monitor
ADC-1000
The ADC-1000 is a high precision Air Data Monitor that can be used as to precisely measure pressures. It can also be used as a transfer standard. The ADC-1000 can be used to verify standards without having to ship them out for calibration. TestVonics also offers an Air Data Transfer program to customers, allowing them to calibrate equipment in-house. This helps prevent damage to equipment in transit, which can be costly and increase organizations downtime.
-
product
Probes And Cables
The iProbe is an intelligent temperature sensor that can be calibrated independently of SBIR’s blackbody systems or 104i precision thermometers. These ultra-stable, highly responsive iProbes are used to provide long term accuracy and repeatability of under 0.010°C. Each iProbe incorporates onboard flash memory that allows all calibration constants and calibration date information to be stored independently of the blackbody or thermometer system. This allows iProbes to be exchanged for use on a b...show more -
product
Tactical Grade Inertial Measurement Unit (IMU)
ADIS16490 iSensor
The ADIS16490 iSensor® device is a complete inertial system that includes a triaxial gyroscope and a triaxial accelerometer. Each inertial sensor in the ADIS16490 combines industry-leading iMEMS® technology with signal conditioning that optimizes dynamic performance. The factory calibration characterizes each sensor for sensitivity, bias, alignment, and linear acceleration (gyroscope bias). As a result, each sensor has its own dynamic compensation formulas that provide accurate sensor measuremen...show more -
product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 7mm, 2 Port
85091D
The Keysight 85091D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
product
Partial Discharge Detection System
JFD-2000
Wuhan Sangao Electrical Test Installations Limit Co.
Ease of use was the mandate to our engineering and design teams. The JFD-2000 uses the worldwide standard Windows operating system and an intuitive control and display panel to allow even inexperienced operators to learn quickly with minimal training. In addition, advanced features such as higher accuracy, auto-mated calibration, data analysis, and customized test recording, are standard. Use as much or as little as you like.
-
product
PXI-6233, 16 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sinking DO, Bank-Isolated, PXI Multifunction I/O Module
779620-01
16 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sinking DO, Bank-Isolated, PXI Multifunction I/O Module—The PXI‑6233 is a bank-isolated DAQ device designed for voltage I/O. It offers analog I/O, digital input, sinking digital output, two 32‑bit counters, and digital triggering. The digital input and outputs are compatible with 24 V signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measurements...show more -
product
Meter Test System
MTS-100
Kongter Test & Measurement Co., Limited
This Meter Test System features state-of-art designing with high accuracy. It is composed of high accurate (class 0.05% or 0.1%) standard reference meter and power source (up to 120A). This system is particularly designed with modular structure for calibration and test of different single phase/3 phase electronic/inductive active and reactive energy meters.
-
product
Electrical Calibration
Process Instruments calibrates a wide variety of test and measurement equipment. All calibration procedures are written, and most are automated, insuring reliability and repeatability of measurements.
-
product
PXI RTD Simulator Module 18-Channel PT1000
40-262-002
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
product
Temperature Calibration
Process Instruments maintains primary temperature standards for the calibration of Standard Platinum Resistance Thermometers. SPRT''s are measured against a Thomas-type Ten Ohm Standard Resistor (a Leeds & Northrup 4211-B), using a Measurements International automated bridge. Primary thermometry points are maintained at the Water, Tin, Zinc and Gallium points.
-
product
Portable Meter Test Systems
Zhengzhou SMS Electric Co.,Ltd
Portable energy meter calibration test devices.
-
product
Antenna Calibration
TDK Test Services offers testing to domestic and international EMC test regulations, including IEC, ISO, CISPR, and SAE. Test services are offered in our 3m semi-anechoic chamber, 3m fully-anechoic chamber, 10-meter open area test site, and our shielded conducted test chamber.
-
product
VELOCICALC Multi-Function Ventilation Meter
9565-A
The portable, handheld VELOCICALC® Multi-Function Ventilation Meter 9565-A features a menu-driven user interface for easy operation in your local language. On-screen prompts and step-by-step instructions guide the user through instrument setup, operation, and field calibration. The 9565-A also features an ergonomic, overmolded case design with probe holder and a keypad lockout to prevent tampering during unattended use. The 9565-A model includes the Articulated Probe 966 and is designed for use with a range of plug-in probes.
-
product
Handheld Water Quality Meters
LAQUA PC220
- Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display- ORP calibration option- Automatic / manual temperature compensation and temperature calibration function- Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Conductivity and total dissolved soli...show more -
product
Calibration Kit
N911
*N911 Calibration Kit, * Frequency Range: up to 9 GHz, * Impedance: 50 Ohm, * Connector Type: N-type.
-
product
Temperature Data Acquisition
THERMES-USB
Physitemp’s Thermes high accuracy data acquisition system has been redesigned to create a more versatile USB model. The new system requires no internal connections to your computer and simply connects via an external USB port on your laptop or desktop computer. Two versions of the data acquisition system are available. The standard version, THERMES USB, is connected to your computer USB port. The wireless version - THERMES USB WFI, can be either directly connected to a USB port or, with the incl...show more -
product
Wide Range Ohmmeter
PAS-853B
- Wide Resistance Measurement Range from 0.01 ohm to 9.99x1012 ohms- Nominal Full Range Tolerance Averages <±5%- Fully Automatic Resistance Range, Test Voltage and Electrification Period Control- Automatic or Continuous Electrification ControlRugged High Performance 80 inches (200cm) Test Leads Included- Powered by one long lasting 9V Alkaline Battery- Large, Easy to Read LCD Display- Meets requirements of ESD Association Standards for material and audit resistance measurement requirements- Certificate of Calibration Traceable to NIST included
-
product
Static Load Cells
2580 Series
Instron® load cells are a key part of a materials testing system. Instron is the only global materials testing supplier that designs and manufactures its own load cells. This ensures that Instron load cells meet the unique requirements of materials testing such as; high accuracy over a wide measurement range, high stiffness, resistance to offset loads, accurate alignment and excellent zero stability. The 2580-xxxN Series load cells are specifically designed for use with 5900 testing systems; off...show more