CT Test
measures insulation, excitation current, turns ratio, winding polarity saturation and/or winding resistance. Current Transformers
- Taylor Dynamometer, Inc.
product
500 HP Complete Bench Hydraulic Test Center
HTC-500
The Hydraulic Test Center (HTC) is a versatile machine designed to test heavy-duty, off-highway hydraulic components. The 500 hp (373 kW) HTC Complete Bench is for the dealer that services components from a predominately larger machine size mix such as large mining machines and large excavators. The Complete Bench offers full functionality to test all types of pumps and motors including: transmissions, hydraulic motors, hydraulic cylinders, valve blocks, torque converters, open and closed loop pumps.
-
product
CT Ratio/Burden Tester
1047
TESCO’s new CT Ratio/Burden Tester (Catalog No. 1047) is a lightweight, portable and highly accurate in-service test set to assist in finding lost revenue by testing the accuracy of your meter circuits. The Tester can help determine if there are installations errors, loose connections, incorrect ratios, resistance buildup, open CT’s, or manufacturers defects. The CT Ratio/Burden Tester measures and displays the primary and secondary current of the CT under test, and the ratio of the currents. All test data is stored in the internal memory and easily uploaded to a PC.
-
product
DR software, for use with CT100 Series TDRs
CT Viewer™
CT Viewer™ is a full-featured TDR waveform analysis software package for Microsoft® Windows® XP / Vista PCs that lets you archive, manipulate, analyze, and compare TDR data acquired with CT100 Series Automated Metallic TDRs or any other TDR instrument, now with live internet streaming and remote control of CT100 Series TDRs. CT Viewer™ is included with CT100 Series TDRs. Read on to discover how CT Viewer™ will change the way you test cables.
-
product
GAOTek Three-Channel Leakage Current Tester
GT00YB00ZV
The GAOTek Three-Channel Leakage Current Tester provides online measurement, monitoring, and recording of three channel AC leakage currents simultaneously by adopting the latest CT and magnetic shielding technology. This instrument provides highly accurate and reliable measurements. Additionally, it can locate insulation faults and repair electrical lines. It is composed of a special alloy and consists of a test monitoring software, current clamp, and communication cable. The instrument can stor...show more -
product
Charger Tester
G5.CT
The G5.CT series are unidirectional regenerative sinks. It was developed specifically for testing chargers and is suitable for use in laboratories and on test benches. The modular and finely graded G5.CT series is characterized by highly dynamic response times and a wide current-voltage range with an auto-ranging factor 3. The G5.CT series can simulate the electrical charging characteristics of a modern battery pack. This includes active voltage output and Ri realtime simulation.
-
product
CT Tester
5000 Bird Dog Plus
Spinlab Utility Instrumentation, Inc.
he Bird Dog Plus is the most complete, easy to use CT test product available on the market! Spinlab has created the most innovative products available to perform meter circuit testing. All 32 failure modes of a meter circuit can be checked with the push of one button. You will be able to thoroughly evaluate any poly-phase meter circuit in less than 10 minutes.
-
product
MXI Computerized Tomography (CT) Option
The Nordson TEST & INSPECTION µCT inspection option provides Computerized Tomography (CT) functionality to compliment the 2D X-ray investigations on Nordson TEST & INSPECTION X-ray inspection systems. It uses the superior, sub-micron feature recognition 2D x-ray images, that Nordson TEST & INSPECTION X-ray systems always provide, to produce the best CT models for 3D sample analysis, virtual micro-sectioning and internal dimensional measurements. It reduces the number of time-consumin...show more -
product
Three-Phase Transformer Demagnetizer
DEM60C
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument trans...show more -
product
Transformer Testing Equipment
Offering you a complete choice of products which include Automatic Transformer Turns Ratio Instruments (ATRI- 3), Automatic Transformer Turns Ratio Instrument (ATRI-201), VTRI-2000 ( Transformer turns ratio instrument ), Current Transformer Test Set (CTC-1), Potential Transformer Tester ( PT Tester ) and Current Transformer Tester ( CT Tester ).
-
product
Instrument Transformer Calibrators
CTPT 81
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Tests: Ratio error. Excitation current and curve. Polarity CT / PT TESTER
-
product
Current Booster
BUX
The current boosters allow performing tests up to 2000A, 3000A and 5000A. The option is made of a module, which incorporates a power transformer, which generates a low-voltage, high current output and a metering CT, which measures the output current and sends the metering to eKAM.
-
product
Relaying Current Transformer Analyser
*Measures Ratio, Excitation Characteristics, Polarity, Winding Resistance, Remanance, and Insulation Resistance of secondary winding. * Determines Composite Error. * Used to test un-mounted CTs or CTs that are mounted but isolated inside the power system equipment. * Conducts a whole series of tests automatically, thus speeding up the time to commission CTs and relaying systems. * Battery powered test set - light weight & fully portable. * Provides a graphical presentation of the CT excitati...show more -
product
Turns Ratio Testing
The transformer turns ratio test, or TTR test, confirms that the transformer has the correct ratio of primary turns to secondary turns. Using this test correctly can help to identify tap changer performance, shorted turns, open windings, incorrect winding connections and other faults inside transformers. Megger’s range of TTR testers are robust to withstand the harsh conditions that some transformer testing in. The range includes varying features to simplify and speed up testing as well as 3 phase TTR testers and PT and CT TTR testers.
-
product
CT & PT Test Kit
PCT200i
PCT200i is specially designed for current transformer characteristic test.This CT analyzer can finish the measurement class CT and TYP class CT.The additional functions include ratio and angle differential tests (the measurement points in the GB standard),FS and inductance,steady-state parameters,peak error and transient parameters,etc.
-
product
Primary Current Injection Test Sets
Our primary current injection test sets cover from 750A through to 6000A. Available in single phase, testing applications include testing and timing of under and over current relays, circuit breakers and CT ratio testing.
-
product
Current And Voltage Transformer Test Set
iCT1
iCT1 - CT/VT Test Set is the NEW and most advanced portable equipment capable to test current, voltage and combined transformers.With the low voltage method, known as "DC method", iCT1 is able to test Current Transformers with a very high saturation voltage, up to 30 kV, in a complete safety mode. Quick and easy to use tool, iCT1 allows to perform tests in one shot without changing the connection to the CT, thanks to the integrated 5-TAP Switchbox.
-
product
Digital Arrester Clamp Tester
ALCL-40
MULTI MEASURING INSTRUMENTS Co., Ltd.
*ALCL-40 is designed to test the diagnostic of OXIDE SURGE ARRESTER.*The least influence from the external magnetic field and noise by triple shielding of CT.*Compliant with IEC6099-5.*Enabled the measurements for 100nA resolution and harmonics current.
-
product
Primary Current Injection Test Set
T 2000
T 2000 is a portable current transformer test set which allows to perform many different measurements such as saturation, ratio and polarity tests and CT winding resistance test. Substation maintenance and commissioning test equipment, T 2000 is extremely appreciated by electrical engineers for its high accuracy and portability.
-
product
Test Switches
Series FT
An industry standard for CT & VT isolationfor instrument transformer and connected device testing.Up to 10 poles; Numerous configurations availableTypically mounted on switchgear and relay panels10 pole test plug available; UL and cUL recognized.
-
product
CT Admittance Tester
505B
Red Phase Instruments Australia Pty Ltd.
Field testing kWh meters is easy, field testing CTs when live is much more difficult. Our admittance tester can test CTs live with 50Hz or 60Hz current in the metering circuit. This technique does not confirm the accuracy of a CT but it will detect faults that give metering errors, such as shorted turns, metering circuits shorted to ground and tampering of CTs. CT faults can cause large revenue losses. Admittance testing only adds 10 minutes to a routine polyphase meter test, giving cheap insurance.
-
product
Digital Arrester Clamp Tester (with Data output)
ALCL-40H
MULTI MEASURING INSTRUMENTS Co., Ltd.
*ALCL-40 is designed to test the diagnostic of OXIDE SURGE ARRESTER.*The least influence from the external magnetic field and noise by triple shielding of CT.*Compliant with IEC6099-5.*Enabled the measurements for 100nA resolution and harmonics current.
-
product
CAM/TRAC Test Kits
Series 40
The CT Series 40 CAM/TRAC mechanical kits, utilizing the patented CAM mechanism, offer precise Z axis linear motion when testing higher point count and finer pitch test centers. By using the Z axis motion, side load of the test probes is minimized thus increasing probe life and performance.
-
product
Secondary Current Injection Test Trolley
SCR ELEKTRONIKS have developed SECONDARY CURRENT INJECTION TEST TROLLEY for Switchgear items, CT manufacturer and where three phase current application is called for. It is low Voltage, 3 phase Current source with control circuitry, digital read out for test current and trip time measurement. We can select different CT ranges for each phase independently and adjust the current as per the required test Current.
-
product
Transformer Demagnetization Tester
Weshine Electric Manufacturing Co., Ltd
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores.
-
product
Test Switches and Accessories
Test switches are designed and manufactured to allow quick and easy multi-circuit testing of switchboard relays, meters and instruments by any conventional system.These test switches and related test plugs have the features necessary for applications involving the measurement of individual currents and voltages associated with substation instrumentation and protection devices. They have been especially designed for the measurement of potential elements, current elements, and make-before-break short-circuit elements related to Current Transformer (CT) circuits.
-
product
Large Current 1000A Primary Current Injection Test Set
TEST-901
Beijing GFUVE Electronics Co.,Ltd.
TEST-901 primary current injection test set adopts ARM Chip to control its output process and large capacity of toroidal transformers. It is equipped with LCD display and current meter; it can show primary current value, second current value, turn ratio and the action time. Packing is used as aluminum alloy body with PC panel. TEST-901 is mainly applied to CT turn ratio testing in the power system and contact resistance test which need large current.
-
product
Current Transformer Test Set
Vanguard Instruments Company, Inc.
The EZCT-2000C is Vanguard’s third-generation microprocessor-based current transformer test set. Designed specifically for CT testing, the EZCT-2000C has the following outstanding features that can greatly increase productivity and save time during the commissioning stage:
-
product
Relay Test Set
RNT-5A
This is a portable testing kit in one unit, suitable for testing protective relay, over current relay, earth fault relay, protective device, circuit breaker, tripping coils etc.The set is designed for both laboratory and field use. TECHNICAL FEATURES: INPUT : 230 Volts, single phase, 50Hz. AC. OUTPUTS : : 1) Current Output: a) 0- 1Amp. At 6/60Volts. (Continuous duty). b) 0- 5 Amps. At 6/60 Volts. (Continuous duty). c) 0- 10 Amps. At 6/60 Volts. (Continuous duty). d) 0- 20 Amps. At 6 Volts. (for3...show more -
product
Hand-held 3-Phase Meter Tester
3 Series
Powermetrix continues its industry leadership with the introduction of Powermetrix Remote Manager (PRM) for the PowerMaster® 3 Series. Powermetrix Remote Manager enables wireless control of essential and various metering site accuracy tests contained within PowerMaster® 3 Series from any Windows compliant system up to 100 feet in any environment, including high EMF environments! Customer load Meter Testing, CT/PT ratio testing, CT/PT burden measurement, meter register/demand testing, and wiring ...show more -
product
Primary Current Injection Testers
Primary current injection tests are carried out during commissioning and certification of various types of switchgear and current transformers (CT), as well as during diagnostics of grounding circuits, testing circuit breakers and other devices. Primary current injection testers can also be used for determining the terminals polarity and transformation ratio of current transformers, thermal testing of electrical devices, testing automatic reclosers and sectional disconnectors.
-
product
CT Polarity Tester
DIR CT
SCOPE proudly introduces Dir CT, a CT Polarity Tester specially designed to verify correctness of polarity of current transformers cores in live EHV switchyards. Polarity test is one of the most common yet crucial tests required to be done on current transformers by commissioning as well as maintenance engineers. Even though it is commonly conducted check, there was no all in one simple tool available for this measurement. DIR CT fills this void to perfection, it is expected to significantly reduce the time taken for polarity checks on numerous CT in sub-station, especially during commissioning of new sub-stations