Showing results: 181 - 195 of 289 items found.
-
NC2000/4000 Series -
Noisecom
The NC2000 Series amplified noise modules are an excellent choice for high-level noise modules mounted on a circuit board. The NC2000 Series modules are housed in 24, or14-pin dual-inline packages. The NC4000 series modules are housed in a 40-pin module that cover similar noise bands to the NC2000, but have higher crest factor, and 60 dB of TTL controlled attenuation.
-
Teledyne RF & Microwave
Gain Shape amplifiers are used in a number of applications where it's necessary to flatten the gain characteristic of the preceding or following component. This would include flattening the attenuation of a long cable run or perhaps changing the input gain response to a MPM (Microwave Power Module) or TWT (Traveling Wave Tube) to compensate for the gain variation within the tube.
-
Teledyne RF & Microwave
Gain Shape Linearizer Amplifiers are used in a number of applications where it's necessary to flatten the gain characteristic of the preceding or following component. This would include flattening the attenuation of a long cable run, or perhaps changing the input gain response to a MPM (Microwave Power Module) or TWT (Traveling Wave Tube) to compensate for the gain variation within the tube.
-
Teledyne Defense Electronics
Gain Shape Linearizer Amplifiers are used in a number of applications where it's necessary to flatten the gain characteristic of the preceding or following component. This would include flattening the attenuation of a long cable run, or perhaps changing the input gain response to an MPM (Microwave Power Module) or TWT (Traveling Wave Tube) to compensate for the gain variation within the tube.
-
E1708A -
Keysight Technologies
The Keysight E1708A uses an optical fiber to transport the laser beam from a remote sensor assembly to the electronics. This improves measurement accuracy and repeatability by enabling you to mount heat-producing electronics away from the measurement area. The fiber optic cable also provides increased mounting design flexibility and easier access to the receiver attenuation and squelch adjustments.
-
M9168E -
Keysight Technologies
The M9168E is a programmable step attenuator module based on PXI hybrid platform. The M9168E operates from DC to 50 GHz with a guaranteed 0.03 dB insertion loss repeatability for each section throughout the 5 million cycles operating life. Superior attenuation accuracy across a wide operating temperature range ensures precise measurements.
-
M9168C -
Keysight Technologies
The M9168C is a programmable step attenuator module based on PXI hybrid platform. The M9168C operates from DC to 26.5 GHz with a guaranteed 0.03 dB insertion loss repeatability for each section throughout the 5 million cycles operating life. Superior attenuation accuracy across a wide operating temperature range ensures precise measurements.
-
Teledyne LeCroy
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a /10 attenuation and feature a high input resistance of 10 MOhm. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400 V, some as high as 600 V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
JW3226A -
Shanghai Joinwit optoelectronic Tech,co.,Ltd
JW3226A CWDM Power Meter is specially designed for CWDM system, covering wavelength from 1270~1610nm.It measures and monitors optical power and attenuation value of 18 channels from wavelength 1270nm to 1610nm wavelength.
-
Daqarta
When the Generator is active, the actual output levels are controlled by the Volume/dB dialog (F9 key, or button on the Generator Control dialog), but the screen display remains full-scale because it shows the digital signal as generated, before conversion to analog and attenuation by the output mixer volume controls. (The digital waveform size is set by the Generator Level controls for the active streams on each channel.)
-
CT4432 -
Cal Test Electronics
Because an oscilloscope has limits to the input voltage itcan accept, measuring higher voltages may sometimes require the use of anattenuating high-voltage probe. The CT4432, with an improved dual-resistor design, can accurately and safely step-downhigher voltages to an acceptable level. It offers 1000x attenuation and features a compensation range of 5 pF to 50 pF for a wide range ofoscilloscope capacitance matching.
-
6HP-9060 -
Prokit's Industries Co., Ltd.
Switchable X1/X10/X100 attenuation with reference switch positions. Break-resistant center conductor & wide compensation range. Flatter response, sharper leading edges. Faster rise time and replaceable cable probe head tip and ground lead. Max. input voltage: 600V/1200V (DC-peak AC). Includes BNC adapter, IC tip, insulating tip & trimming tool.
-
N2889A -
Keysight Technologies
The Keysight N2889A low-cost passive probe provides up to 350 MHz bandwidth and features high-input resistance of 10 MΩ (@10:1 mode) to address a wide range of measurement needs with low probe loading. The N2889A comes with a convenient switch in the probe handle that lets you switch between a 1:1 and 10:1 attenuation ratio.
-
JW8506 -
Shanghai Joinwit optoelectronic Tech,co.,Ltd
JW8506-VOA Variable optical attenuator is JOINWIT specially designed for the current optical transceiver, optical network integration test. It is the test equipment with excellent performance. JW8506-VOA Variable optical attenuator through the design of high density,greatly saves equipment cover space,multi-channel independent optical attenuation provides a higher rate of test date throughput and test,the device also provides several communication interface,can support system integration with Joinwit testers. It is the ideal solution of 40G/100G optical module、optical network、optical attenuation sensitivity in optical transmission field and error rate.
-
DP-60HS -
PINTEK Electronics
*High Sensitivity Model: x 1, x 5, x 10 Attenuation*1 MΩ // 10PF Input Impedance*High Frequency Operation: x 1(30 MHZ), x 5(60 MHZ), x 10(60 MHz)*Especially For Low Voltage: x 1(7 Vp-p), x 5(35 Vp-p), x 10(70 Vp-p)